KMC Controls FlexStat Quick Reference Guide

Controller/Sensor/Thermostat
Quick Reference Guide
FlexStat
Home Screen
WED 9/3 5:43 PM
COOL:
OCC:
FAN:
HUM: 31%RH
Override Screens
SYSTEM MODE
SYSTEM ENABLE:
OCCUPANCY OVERRIDE
OCC OVERRIDE:
FAN MODES
UNOCC:
OCC: AUTO
AUTO
OFF
AUTO
Setpoint Adjustment
Up (Setpoint)
Override
Left
(Override)
Down (Setpoint)
Navigation
Navigate the menus and change seings by press­ing a combination of various arrow buons and the (center round) Enter buon. Push the:
Configuration Screens
MAIN MENU ABOUT ADVANCED ALARM DATE/TIME
SCHEDULE
SETPOINTS SYSTEM
Right
Configuration
(Menu)
SCHEDULE
ENTIRE WEEK [MON–SUN]
WEEKDAYS [MON–FRI] WEEKEND [SAT–SUN] INDIVIDUAL DAYS HOLIDAYS
ENTIRE WEEK
7:30:00 AM ON
1:
2: 5:15:00 PM OFF 3: 4: 5: 6: [—>] DELETES ENTRY

Room Temperature Setpoint Adjustment

From the Home (temperature display) screen, press the Up or Down arrow buon once to view the exist­ing setpoint.
• Enter buon to select and/or exit value editing.
• Up or Down buon to move among entries.
• Right or Left buon to move among value elds.
To temporarily change the setpoint, press the Up or Down arrow buon repeatedly until the desired seing is displayed and press Enter. (If Enter is not pressed, the display will return to the Home screen after about ten seconds and the new setpoint value
• Left buon to return to the Home screen.
NOTE: Access to various functions may require a
password.
NOTE: See the FlexStat Operation Guide for
complete details on FlexStat conguration.
will still be saved.) The new setpoint will hold until the next schedule change.
To permanently change the setpoint for occupied mode, go to the Setpoints section under the Main Menu. (In the Setpoints menu, heating/cooling set­points/setbacks and deadband can be changed with, if required, the correct password access.)
FlexStat 1 Quick Reference Guide

Heat/Cool, Fan, Occupancy, and Override

5. Enter to exit value editing.
When the fan is commanded to run, the animated FAN icon on the display rotates (if programmed to). When the fan command stops, the fan icon is mo­tionless.
The OCC icon shows a sun when in Occupied mode and a quarter moon when in Unoccupied mode.
HEAT or COOL will show (and be animated when there is an active command to move the room tem­perature toward the setpoint via mechanical heating/ cooling or an economizer), depending on the current mode. This can also be turned OFF.
To override these modes from the Home (tempera­ture display) screen, press the Left arrow buon. Press Up or Down to get to the desired line and then Enter (twice) to edit the mode seing. Press Left to exit to Home.

Main Menu and Settings

From the Home (temperature display) screen, press the Right arrow buon to enter the Main Menu.
NOTE: Seings and adjustments may require a
password.

Schedules

SCHEDULE
ENTIRE WEEK [MON–SUN]
WEEKDAYS [MON–FRI] WEEKEND [SAT–SUN] INDIVIDUAL DAYS HOLIDAYS
ENTIRE WEEK
1:
7:30:00 AM ON
2: 5:15:00 PM OFF 3: 4: 5: 6: [—>] DELETES ENTRY
6. Left to move back to days or back one page.
NOTE: If a day of a week (e.g., Friday) has a
dierent schedule than the rest, using the Weekdays menu rst and then modifying that one day in the Individual Days menu may be easier (two entries) than entering schedules for each day separately in the Individual Days menu (ve entries).
NOTE: The last overlapping entry overrides
any other. For example, suppose the WEEKDAYS menu is used to set all weekdays for 7:00 AM ON and 5:00 PM OFF, and then the INDIVIDUAL DAYS menu is used to add some additional evening meeting ON times for Tuesday and Wednesday. If the WEEKDAYS menu is later used to change the ON time from 7:00 to 7:15, schedules for all the individual week days will be reset to conform to what appears in the WEEKDAYS menu and any special times for individual days will be erased. (Special day schedules will then need to be added again through the INDIVIDUAL DAYS menu).
The Holiday entries will override the normal occupied weekly schedule entries and keep those days’ seings at their setback values. (Setback values are entered in the Setpoints section of the Main Menu.)
HOLIDAYS
HOL1:
JAN 1 2009 HOL2: MAR 21 2009 HOL3: MAY 26 2009 HOL4: JULY 4 2009 HOL5: SEPT 1 2009 HOL6: NOV 27 2009 HOL7: NOV 28 2009
The factory default schedule is always occupied (ON). To modify the schedule for mixed occupied
NOTE: See the FlexStat Operation Guide for more
operation details.
(ON) and unoccupied (OFF) times, select Schedules in the Main Menu and press:
1. Right/Left to move among days and Enter to select.
KMC Controls, Inc.
19476 Industrial Drive
2. Up/Down to move among entries and Enter to select and edit.
New Paris, IN 46553
574.831.5250
3. Right/Left to move among value elds.
4. Up/Down to increment/decrement value.
© 2014 KMC Controls, Inc. 913-019-06C
FlexStat 2 Quick Reference Guide
(Specifications, design, and operation are subject to change without notice)
www.kmccontrols.com