Kmc controls BAC-7302, BAC-7302C Operation Guide

Installation and Operation Guide
BAC-7302 and BAC-7302C
Advanced Applications Controller
Section 1
About the BAC-7302
Specifications ........................................................................................................................ 3
Accessories ............................................................................................................................ 6
Safety considerations ..........................................................................................................7
Section 2
Installing the controller
Mounting .............................................................................................................................. 9
Connecting inputs ............................................................................................................... 9
Connecting to a NetSensor ............................................................................................... 11
Connecting to an MS/TP network .................................................................................. 11
Programming ..................................................................................................................... 14
Section 3
Operating the controller
Operation ............................................................................................................................ 15
Controls and Indicators .................................................................................................... 15
Restoring factory settings ................................................................................................. 18
905-019-53FRevision F
KMC Controls
Important notices
©2013, KMC Controls, Inc.
WinControl XL Plus, NetSensor, and the KMC logo are registered trademarks of KMC Controls, Inc.
BACstage and TotalControl are trademarks of KMC Controls, Inc.
MS/TP automatic MAC addressing is protected under United States Patent Number 7,987,257.
All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of KMC Controls, Inc.
Printed in U.S.A.
Disclaimer
The material in this manual is for information purposes only. The contents and the product it describes are subject to change without notice. KMC Controls, Inc. makes no representations or warranties with respect to this manual. In no event shall KMC Controls, Inc. be liable for any damages, direct or incidental, arising out of or related to the use of this manual.
KMC Controls
P. O . B o x 4 9 7 19476 Industrial Drive New Paris, IN 46553 U.S.A. TEL: 1.574.831.5250 FAX: 1.574.831.5252 E-mail: info@kmccontrols.com
Revision F2
BAC-7302 RTU Controller
SECTION 1

About the BAC-7302

This section provides a general description of the KMC Controls BAC-7302 controller. It also introduces safety information. Review this material before installing or operating the controller.
The BAC-7302 is a native BACnet, fully programmable controller designed for roof top units. Use this versatile controller in stand-alone environments or networked to other BACnet devices. As part of a complete facilities management system, the BAC-7302 controller provides precise monitoring and control of connected points.
BACnet MS/TP compliant
Automatically assigns the MAC address and the device instance
Triac outputs for fan control, two-stage heating and two-stage cooling
Supplied with programming sequences for roof top units
Easy to install, simple to configure, and intuitive to program
Controls room temperature, humidity, fans, monitors refrigeration, lighting,
and other building automation functions.

Specifications Inputs

Universal inputs 4 Key features Software selectable as analog, binary or accumulator
Pull–up resistors Switch select none or 10k. Connector Removable screw terminal block, wire size
Conversion 10–bit analog–to–digital conversion Pulse Counting Up to 16 Hz Input range 0–5 volts DC NetSensor Compatible with models KMD–1161 and KMD–1181.
Outputs, Universal 1
Key features Output short protection
Connector Removable screw terminal block
Output voltage 0–10 volts DC analog
Output current 100 mA per output
objects. Accumulators limited to three in one controller. Standard units of measure. NetSensor compatible Overvoltage input protection
AWG
14–22
Programmable as an analog or binary object. Standard units of measure
Wire size 14-22 AWG
0–12 volts DC binary output range
Revision F 3
About the BAC-7302
Specifications
KMC Controls
Outputs, Single-stage triac 1
Key features Optically isolated triac output.
Programmable a binary object.
Connector Removable screw terminal block
Wire size 14-22 AWG
Output range Maximum switching 30 volts AC at 1 ampere
Outputs, Dual-stage triac 2
Key features Optically isolated triac output.
Programmable as binary object.
Connector Removable screw terminal block
Wire size 14-22 AWG
Output range Maximum switching 30 volts AC at 1 ampere
Communications
BACnet MS/TP EIA–485 operating at rates up to 76.8 kilobaud.
Automatic baud detection. Automatically assigns MAC addresses and device instance numbers. Removable screw terminal block. Wire size 14–22 AWG
NetSensor Compatible with models KMD–1161 and KMD–1181,
Connects through RJ–12 connector.
Programmable features
Control Basic 10 program areas PID loop objects 4 loop objects Value objects 40 analog and 40 binary Time keeping Real time clock with power backup for 72 hours
(BAC-7302-C only) See PIC statement for supported BACnet objects
Schedules
Schedule objects 8 Calendar objects 3
Trend objects 8 objects each of which holds 256 samples
Alarms and events
Intrinsic reporting Supported for input, output, value, accumulator,
trend and loop objects.
Notification class objects 8
MemoryPrograms and program parameters are
stored in nonvolatile memory. Auto restart on power failure
4
Revision F
BAC-7302 RTU Controller
About the BAC-7302
Specifications
Application programs KMC Controls supplies the BAC-7302 with
programming sequences for roof top units:
Roof top operation based on occupancy, night
setback, proportional hot and chilled water valve control.
Economizer operation.
Freeze protection.
Regulatory UL 916 Energy Management Equipment
FCC Class B, Part 15, Subpart B BACnet Testing Laboratory listed CE compliant SASO PCP Registration KSA R-103263
Environmental limits
Operating 32 to 120° F (0 to 49° C) Shipping –40 to 140° F (–40 to 60° C) Humidity 0–95% relative humidity (non-condensing)
Installation
Supply voltage 24 voltsAC(–15%,+20%),5060Hz,8VA
minimum,15VAmaximumload,Class2only, nonsupervised(allcircuits,includingsupply voltage,arepowerlimitedcircuits)
Weight 8.2 ounces (112 grams) Case material Flame retardant green and black plastic
Models
BAC-7302C BACnet RTU controller with real-time clock BAC-7302 BACnet RTU controller without real-time clock
Revision F
5
About the BAC-7302
OUT4 GND T3B RTN3 T3A T2B RTN2 T2A RTN1 T1
A
E
B
C
D

Accessories

KMC Controls
Dimensions
Table 1-1 BAC-7302 Dimensions
A B C D E
4.36 in. 6.79 in. 1.42 in. 4.00 in. 6.00 in.
111 mm 172 mm 36 mm 102 mm 152 mm
Accessories Power transformer
XEE-6111-40 Single-hub 120 volt transformer XEE-6112-40 Dual-hub 120 volt transformer