Page 1
Control Relays and Timers
Programmable Relays
3.3
Product Overview
The easyRelays combine
timers, relays, counters,
special functions, inputs and
outputs into one compact
device that is easily
programmed. The easyRelay
family of products provides an
exceptional level of flexibility
together with a substantial
savings of commissioning
time and effort.
The easyRelays are available
in more than 35 styles that
support from 12 I/O up to
a network of up to 320 I/O
points, providing the ideal
solution for lighting, energy
management, industrial
control, irrigation, pump
control, HVAC and home
automation.
Once easyRelays are
installed, changes are
easily accomplished through
front panel programming,
eliminating the need
to change wiring and
minimizing downtime.
The easy802/806 relays are
even more powerful than
the easy800 series and
include an integrated
SmartWire-DT gateway.
Conventional hardwiring
to pushbuttons, selector
switches, pilot devices and
contactors can now be
eliminated, allowing for a
dramatic increase in panel
wiring productivity.
Contents
Description Page
Programmable Relays
easy500/700/800 Programmable Relays . . . . . V7-T3-20
easy802/806 Programmable Relays
with SmartWire-DT . . . . . . . . . . . . . . . . . . . . V7-T3-26
easyRelay and MFD Expansion Modules . . . . . V7-T3-30
MFD-Titan Multi-Function Displays . . . . . . . . . V7-T3-33
easyRelay Communication Modules . . . . . . . . V7-T3-40
easyRelay Power Supplies, Accessories
and Software . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-43
Application Description
The easyRelays excel in
traditional applications where
multiple
pushbuttons
Applications span residential,
commercial and industrial
installations.
Typical control
applications are:
●
●
●
●
●
●
●
relays, timers and
are used.
Lighting controls
Duplex pump controls
Water fountain controls
Parking garage access
controls
Refrigeration control
system
Greenhouse temperature
and ventilation controls
Booster pump controls
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-19
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-19
3
3
3
3
3
3
3
3
3
3
Page 2
3.3
easy500/700/800 Programmable Relays
Display
Blank = Display
X = No display
Digital Outputs
R = Relay
T = Transistor
Clock
C = Clock
Blank = No clock
Digital Inputs
AB = 24 Vac
AC = 110–240 Vac
DA = 12 Vdc
DC = 24 Vdc
Module Type
EASY5xx = 500 Series
EASY7xx = 700 Series
EASY8xx = 800 Series
EASY512 -AC-RC
Control Relays and Timers
Programmable Relays
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
easy500/700/800 Programmable Relays
Product Description
3
3
Three families make up the
easyRelay programmable
3
3
relay product line. All models
are available with and without
3
3
displays. DIN rail mounted.
easy500 —for controlling
3
3
small applications with up
to 12 input/output signals.
3
3
Connectable to Ethernet.
easy700 —for controlling
3
3
medium-sized applications
with 20 I/O points (expandable
3
3
to 40 I/O points). Connectable
to Ethernet and bus systems.
3
3
easy800 —for controlling
large-scale applications
3
3
with 20 points, expandable
to 40 points locally, and
3
3
expandable using the
easyNet network up to
3
3
320 I/O points. Connectable
to Ethernet and bus systems.
3
3
The easyNet integrated
network provides easy and
3
3
inexpensive linking of up
to eight easy800 devices
3
3
over a distance of up to
1000 meters. Each easy800
device can run its own
3
3
program, or be used as a
distributed input/output
3
3
3
3
3
3
3
3
module. Connect up to
eight controllers with up
to 40 I/O to obtain 320 I/O.
V7-T3-20 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
V7-T3-20 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
Standards
●
CSA C22.2 No. 142-M1987
●
CSA C22.2 No. 213-M1987
●
EN 55011
●
EN 50178
●
EN 61131-2
●
IEC EN 61000-4
●
IEC 60068-2-6
●
IEC 60068-2-27
●
UL 508
Certifications
●
UL
●
CSA
●
CE
●
CSA Class I, Div. 2,
Groups A, B, C, D;
Temp. Code T3C
●
C-Tick
●
GOST-R
●
Ukrain-GOST
Shipping Approvals
●
Bureau Veritas
●
Det Norske Veritas
●
Germanischer Lloyd
●
Lloyd’s Register of Shipping
Contents
Description Page
easy500/700/800 Programmable Relays
System Overview . . . . . . . . . . . . . . . . . . . . . . . V7-T3-21
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T3-23
Technical Data and Specifications. . . . . . . . . . . V7-T3-24
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-25
easy802/806 Programmable Relays
with SmartWire-DT . . . . . . . . . . . . . . . . . . . . . . . V7-T3-26
easyRelay and MFD Expansion Modules . . . . . . . V7-T3-30
MFD-Titan Multi-Function Displays . . . . . . . . . . . . V7-T3-33
easyRelay Communication Modules . . . . . . . . . . . V7-T3-40
easyRelay Power Supplies, Accessories
and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-43
Catalog Number Selection
easy500/700/800
Note: Not all combinations are possible. See selection tables.
Page 3
Control Relays and Timers
Item Description
1 easy500 basic devices, standalone
2 easy700 basic devices, expandable:
digital inputs/outputs, bus systems
3 MFD-Titan remote text display
4 Ethernet gateway
5 PROFIBUS-DP bus module
6 AS-Interface bus module
7 CANopen bus module
8 DeviceNet bus module
9 Output expansion
10, 11 I/O expansions
12 Coupling module for the remote connection
of a digital input/output expansion
Programmable Relays
3.3
System Overview
easy500/700 Programmable Relays
1
2
3
3
3
3
3
3
4
5
6
7
8
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-21
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-21
3
3
3
3
3
3
3
3
3
3
11
12
10
9
11
10
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Page 4
3.3
4
5
7
6
3
2
8
9, 12
10
12
10
11
13
1
Item Description
1 easy800 basic devices, expandable:
digital inputs/outputs and bus systems,
easyNet onboard
2 MFD-Titan remote text display
3 Ethernet gateway
4 PROFIBUS-DP bus module
5 AS-Interface bus module
6 CANopen bus module
7 DeviceNet bus module
8 Output expansion
9, 10 I/O expansions
11 Coupling module for the remote connection of
a digital input/output expansion
12 I/O expansion
13 MFD-Titan multi-function display
easy800 Programmable Relay
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Control Relays and Timers
Programmable Relays
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V7-T3-22 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
V7-T3-22 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
Page 5
Control Relays and Timers
easy500—Display
easy500—No Display
easy700—Display
easy700—No Display
easy800—Display
easy800—No Display
Programmable Relays
3.3
Product Selection
easy500 Programmable Relays (Standalone)
Inputs Outputs
Display
12 I/O, no clock — 8 — — — 4 — EASY512-AC-R
———8 2 4 — EASY512-DC-R
1 2 I / O , c l o c k8 ———2 4 — EASY512-AB-RC
—8 ——— 4 — EASY512-AC-RC
——8 —2 4 — EASY512-DA-RC
———8 2 4 — EASY512-DC-RC
———8 2 —4 EASY512-DC-TC
No Display
1 2 I / O , c l o c k8 ———2 4 — EASY512-AB-RCX
—8 ——— 4 — EASY512-AC-RCX
——8 —2 4 — EASY512-DA-RCX
———8 2 4 — EASY512-DC-RCX
———8 2 —4 EASY512-DC-TCX
easy700 Programmable Relays (Expandable and Networkable)
Inputs Outputs
Display
1 8 I / O , c l o c k1 2 ———4 6 — EASY719-AB-RC
—1 2——— 6 — EASY719-AC-RC
——1 2—4 6 — EASY719-DA-RC
———1 24 6 — EASY719-DC-RC
2 0 I / O , c l o c k———1 2 4 —8 EASY721-DC-TC
No Display
1 8 I / O , c l o c k1 2 ———4 6 — EASY719-AB-RCX
—1 2——— 6 — EASY719-AC-RCX
——1 2—4 6 — EASY719-DA-RCX
———1 24 6 — EASY719-DC-RCX
2 0 I / O , c l o c k———1 2 4 —8 EASY721-DC-TCX
easy800 Programmable Relays (Expandable and Networkable)
Inputs Outputs
Display
18 I/O, clock 12 — — 6 — — EASY819-AC-RC
—1 24 6 —— EASY819-DC-RC
19 I/O, clock — 12 4 6 — 1 EASY820-DC-RC
20 I/O, clock — 12 4 — 8 — EASY821-DC-TC
21 I/O, clock — 12 4 — 8 1 EASY822-DC-TC
No Display
18 I/O, clock 12 — — 6 — — EASY819-AC-RCX
—1 24 6 —— EASY819-DC-RCX
19 I/O, clock — 12 4 6 — 1 EASY820-DC-RCX
20 I/O, clock — 12 4 — 8 — EASY821-DC-TCX
21 I/O, clock — 12 4 — 8 1 EASY822-DC-TCX
Note
1
Analog inputs optional. Use of analog inputs will result in a decrease in the same number of available digital inputs.
1
1
1
Relay Transistor Analog
Relay Transistor
Relay Transistor
Catalog
Number Description 24 Vac 110–240 Vac 12 Vdc 24 Vdc Analog
Catalog
Number Description 24 Vac 110–240 Vac 12 Vdc 24 Vdc Analog
Catalog
Number Description 110–240 Vac 24 Vdc Analog
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-23
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-23
Page 6
Control Relays and Timers
3.3
Technical Data and Specifications
3
3
easy500 Series
Type EASY512-AB… EASY512-AC… EASY512-DA… EASY512-DC-R… EASY512-DC-TC.
3
3
Supply voltage 24 Vac 100–240 Vac 12 Vdc 24 Vdc 24 Vdc
3
3
Heat dissipation 5 VA 5 VA 2 W 2 W 2 W
Continuous current outputs
3
3
Short-circuit proof with power factor 1 Line protection B16, 600 A —
Short-circuit proof with power factor 0.7…0.7 Line protection B16, 900 A —
3
3
Mounting On 35 mm DIN rail or screw mounting with ZB4-101-GF1 mounting feet
Connection cables
3
3
Solid 0.2–4.0 mm
3
3
Flexible 0.2–2.5 mm
Degree of protection IP20 IP20 IP20 IP20 IP20
3
3
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
Ambient operating temperature –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C
3
3
Transport and storage temperature –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C
Hazardous location CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
3
3
easy700 Series
3
3
Type EASY719-AB… EASY719-AC… EASY719-DA… EASY719-DC-RC… EASY721-DC-TC.
3
3
Supply voltage 24 Vac 100–240 Vac 12 Vdc 24 Vdc 24 Vdc
Heat dissipation 7 VA 10 VA 3.5 W 3.5 W 3.5 W
3
3
Continuous current outputs
Short-circuit proof with power factor 1 Line protection B16, 600 A Line protection B16, 600 A Line protection B16, 600 A Line protection B16, 600 A —
3
3
Short-circuit proof with power factor 0.7…0.7 Line protection B16, 900 A Line protection B16, 900 A Line protection B16, 900 A Line protection B16, 900 A —
Mounting On 35 mm DIN rail or screw mounting with ZB4-101-GF1 mounting feet
3
3
Connection cables
Solid 0.2–4.0 mm
3
3
Flexible 0.2–2.5 mm
3
3
Degree of protection IP20 IP20 IP20 IP20 IP20
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
3
3
Ambient operating temperature –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C
Transport and storage temperature –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C
3
3
Hazardous location CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
3
3
easy800 Series
Type EASY819-AC… EASY819-DC-RC… EASY820-DC-RC… EASY821-DC-TC… EASY822-DC-TC.
3
3
Supply voltage 100–240 Vac 24 Vdc 24 Vdc 24 Vdc 24 Vdc
3
3
Heat dissipation 10 VA 3.4 W 3.4 W 3.4 W 3.4 W
Continuous current outputs
3
3
Short-circuit proof with power factor 1 Line protection B16, 600 A Line protection B16, 600 A Line protection B16, 600 A Line protection B16, 600 A —
Short-circuit proof with power factor 0.7…0.7 Line protection B16, 900 A Line protection B16, 900 A Line protection B16, 900 A Line protection B16, 900 A —
3
3
Mounting On 35 mm DIN rail or screw mounting with ZB4-101-GF1 mounting feet
Connection cables
3
3
Solid 0.2–4.0 mm
3
3
Flexible 0.2–2.5 mm
Degree of protection IP20 IP20 IP20 IP20 IP20
3
3
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
Ambient operating temperature –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C
3
3
Transport and storage temperature –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C
Hazardous location CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
3
3
Note
1
3
3
Relay = 8 A (10 A to UL) with resistive load, 3 A with inductive load. Transistor outputs = 0.5 A/24 Vdc, maximum four outputs switchable in parallel.
Programmable Relays
1
1
1
8 A8 A8 A8 A0 . 5 A
8 A8 A8 A8 A0 . 5 A
8 A8 A8 A8 A0 . 5 A
2
(AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12)
V7-T3-24 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
V7-T3-24 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
Page 7
Control Relays and Timers
2.81 (71.5)
1.41
(35.8)
3.54
(90.0)
4.02
(102.0)
4.33
(110.0)
1.97 (50.0) 0.42 (10.8)
(M4)
0.157
(3.9)
Dia.
2.28 (58.0)
1.77
(45.0)
0.18 (4.5)
2.22 (56.5)
1.87 (47.5)
easy500
4.23 (107.5)
3.54
(90.0)
4.02
(102.0)
4.33
(110.0)
2.96 (75.0) 0.64 (16.3) 0.64 (16.3)
(M4)
0.157
(3.9)
Dia.
easy700
2.28 (58.0)
2.22 (56.5)
1.87 (47.5)
1.77
(45.0)
0.18 (4.5)
4.23 (107.5)
3.54
(90.0)
4.02
(102.0)
4.33
(110.0)
2.96 (75.0) 0.64 (16.3)
(M4)
0.157
(3.9)
Dia.
0.64 (16.3)
2.83 (72.0)
1.77
(45.0)
2.78 (70.5)
1.91 (48.5)
easy800
0.18 (4.5)
Programmable Relays
3.3
Dimensions
Approximate Dimensions in Inches (mm)
easy500 Series, Drawing Number MD05013001E
easy700 Series, Drawing Number MD05013002E
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
easy800 Series, Drawing Number MD05013003E
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-25
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-25
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3