Klockner-Moeller, Div of Eaton Corp. Programmable Relays Catalog Page

Page 1
Control Relays and Timers
Programmable Relays
Programmable Relays
3.3
Product Overview
The easyRelays combine timers, relays, counters, special functions, inputs and outputs into one compact device that is easily programmed. The easyRelay family of products provides an exceptional level of flexibility together with a substantial savings of commissioning time and effort.
The easyRelays are available in more than 35 styles that support from 12 I/O up to a network of up to 320 I/O points, providing the ideal solution for lighting, energy management, industrial control, irrigation, pump control, HVAC and home automation.
Once easyRelays are installed, changes are easily accomplished through front panel programming, eliminating the need to change wiring and minimizing downtime.
The easy802/806 relays are even more powerful than the easy800 series and include an integrated SmartWire-DT gateway. Conventional hardwiring to pushbuttons, selector switches, pilot devices and contactors can now be eliminated, allowing for a dramatic increase in panel wiring productivity.
Contents
Programmable Relays
easy500/700/800 Programmable Relays . . . . . V7-T3-20
easy802/806 Programmable Relays
with SmartWire-DT . . . . . . . . . . . . . . . . . . . . V7-T3-26
easyRelay and MFD Expansion Modules . . . . . V7-T3-30
MFD-Titan Multi-Function Displays . . . . . . . . . V7-T3-33
easyRelay Communication Modules . . . . . . . . V7-T3-40
easyRelay Power Supplies, Accessories
and Software . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-43
Application Description
The easyRelays excel in traditional applications where multiple pushbuttons Applications span residential, commercial and industrial installations.
Typical control applications are:
relays, timers and
are used.
Lighting controls Duplex pump controls Water fountain controls Parking garage access
controls Refrigeration control
system Greenhouse temperature
and ventilation controls Booster pump controls
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-19
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-19
3
3
3
3
3
3
3
3
3
3
Page 2
3.3
easy500/700/800 Programmable Relays
Display
Blank = Display
X = No display
Digital Outputs
R = Relay T = Transistor
Clock
C = Clock
Blank = No clock
Digital Inputs
AB = 24 Vac AC = 110–240 Vac DA = 12 Vdc DC = 24 Vdc
Module Type
EASY5xx = 500 Series EASY7xx = 700 Series EASY8xx = 800 Series
EASY512 -AC-RC
Control Relays and Timers
Programmable Relays
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
easy500/700/800 Programmable Relays
Product Description
3
3
Three families make up the easyRelay programmable
3
3
relay product line. All models are available with and without
3
3
displays. DIN rail mounted. easy500—for controlling
3
3
small applications with up to 12 input/output signals.
3
3
Connectable to Ethernet. easy700—for controlling
3
3
medium-sized applications with 20 I/O points (expandable
3
3
to 40 I/O points). Connectable to Ethernet and bus systems.
3
3
easy800—for controlling large-scale applications
3
3
with 20 points, expandable to 40 points locally, and
3
3
expandable using the easyNet network up to
3
3
320 I/O points. Connectable to Ethernet and bus systems.
3
3
The easyNet integrated network provides easy and
3
3
inexpensive linking of up to eight easy800 devices
3
3
over a distance of up to 1000 meters. Each easy800 device can run its own
3
3
program, or be used as a distributed input/output
3
3
3
3
3
3
3
3
module. Connect up to eight controllers with up to 40 I/O to obtain 320 I/O.
V7-T3-20 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
V7-T3-20 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
Standards
CSA C22.2 No. 142-M1987
CSA C22.2 No. 213-M1987
EN 55011
EN 50178
EN 61131-2
IEC EN 61000-4
IEC 60068-2-6
IEC 60068-2-27
UL 508
Certifications
UL
CSA
CE
CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
C-Tick
GOST-R
Ukrain-GOST
Shipping Approvals
Bureau Veritas
Det Norske Veritas
Germanischer Lloyd
Lloyd’s Register of Shipping
Contents
easy500/700/800 Programmable Relays
System Overview . . . . . . . . . . . . . . . . . . . . . . . V7-T3-21
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T3-23
Technical Data and Specifications. . . . . . . . . . . V7-T3-24
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-25
easy802/806 Programmable Relays
with SmartWire-DT . . . . . . . . . . . . . . . . . . . . . . . V7-T3-26
easyRelay and MFD Expansion Modules . . . . . . . V7-T3-30
MFD-Titan Multi-Function Displays . . . . . . . . . . . . V7-T3-33
easyRelay Communication Modules . . . . . . . . . . . V7-T3-40
easyRelay Power Supplies, Accessories
and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-43
Catalog Number Selection
easy500/700/800
Note: Not all combinations are possible. See selection tables.
Page 3
Control Relays and Timers
Item Description
1 easy500 basic devices, standalone
2 easy700 basic devices, expandable:
digital inputs/outputs, bus systems
3 MFD-Titan remote text display
4 Ethernet gateway
5 PROFIBUS-DP bus module
6 AS-Interface bus module
7 CANopen bus module
8 DeviceNet bus module
9 Output expansion
10, 11 I/O expansions
12 Coupling module for the remote connection
of a digital input/output expansion
Programmable Relays
3.3
System Overview
easy500/700 Programmable Relays
1
2
3
3
3
3
3
3
4
5
6
7
8
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-21
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-21
3
3
3
3
3
3
3
3
3
3
11
12
10
9
11
10
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Page 4
3.3
4
5
7
6
3
2
8
9, 12
10
12
10
11
13
1
Item Description
1 easy800 basic devices, expandable:
digital inputs/outputs and bus systems, easyNet onboard
2 MFD-Titan remote text display
3 Ethernet gateway
4 PROFIBUS-DP bus module
5 AS-Interface bus module
6 CANopen bus module
7 DeviceNet bus module
8 Output expansion
9, 10 I/O expansions
11 Coupling module for the remote connection of
a digital input/output expansion
12 I/O expansion
13 MFD-Titan multi-function display
easy800 Programmable Relay
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Control Relays and Timers
Programmable Relays
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V7-T3-22 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
V7-T3-22 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
Page 5
Control Relays and Timers
easy500—Display
easy500—No Display
easy700—Display
easy700—No Display
easy800—Display
easy800—No Display
Programmable Relays
3.3
Product Selection
easy500 Programmable Relays (Standalone)
Inputs Outputs
Display
12 I/O, no clock 8 4 EASY512-AC-R
———8 2 4 — EASY512-DC-R
12 I/O, clock8 ———2 4 — EASY512-AB-RC
—8 ——— 4 — EASY512-AC-RC
——8 —2 4 — EASY512-DA-RC
———8 2 4 — EASY512-DC-RC
———8 2 —4 EASY512-DC-TC
No Display
12 I/O, clock8 ———2 4 — EASY512-AB-RCX
—8 ——— 4 — EASY512-AC-RCX
——8 —2 4 — EASY512-DA-RCX
———8 2 4 — EASY512-DC-RCX
———8 2 —4 EASY512-DC-TCX
easy700 Programmable Relays (Expandable and Networkable)
Inputs Outputs
Display
18 I/O, clock12 ———4 6 — EASY719-AB-RC
—12——— 6 — EASY719-AC-RC
——12—4 6 — EASY719-DA-RC
———124 6 — EASY719-DC-RC
20 I/O, clock———12 4 —8 EASY721-DC-TC
No Display
18 I/O, clock12 ———4 6 — EASY719-AB-RCX
—12——— 6 — EASY719-AC-RCX
——12—4 6 — EASY719-DA-RCX
———124 6 — EASY719-DC-RCX
20 I/O, clock———12 4 —8 EASY721-DC-TCX
easy800 Programmable Relays (Expandable and Networkable)
Inputs Outputs
Display
18 I/O, clock 12 6 EASY819-AC-RC
—124 6 —— EASY819-DC-RC
19 I/O, clock 12 4 6 1 EASY820-DC-RC
20 I/O, clock 12 4 8 EASY821-DC-TC
21 I/O, clock 12 4 8 1 EASY822-DC-TC
No Display
18 I/O, clock 12 6 EASY819-AC-RCX
—124 6 —— EASY819-DC-RCX
19 I/O, clock 12 4 6 1 EASY820-DC-RCX
20 I/O, clock 12 4 8 EASY821-DC-TCX
21 I/O, clock 12 4 8 1 EASY822-DC-TCX
Note
1
Analog inputs optional. Use of analog inputs will result in a decrease in the same number of available digital inputs.
1
1
1
Relay Transistor Analog
Relay Transistor
Relay Transistor
Catalog NumberDescription 24 Vac 110–240 Vac 12 Vdc 24 Vdc Analog
Catalog NumberDescription 24 Vac 110–240 Vac 12 Vdc 24 Vdc Analog
Catalog NumberDescription 110–240 Vac 24 Vdc Analog
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-23
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-23
Page 6
Control Relays and Timers
3.3
Technical Data and Specifications
3
3
easy500 Series
Type EASY512-AB… EASY512-AC… EASY512-DA… EASY512-DC-R… EASY512-DC-TC.
3
3
Supply voltage 24 Vac 100–240 Vac 12 Vdc 24 Vdc 24 Vdc
3
3
Heat dissipation 5 VA 5 VA 2 W 2 W 2 W
Continuous current outputs
3
3
Short-circuit proof with power factor 1 Line protection B16, 600 A
Short-circuit proof with power factor 0.7…0.7 Line protection B16, 900 A
3
3
Mounting On 35 mm DIN rail or screw mounting with ZB4-101-GF1 mounting feet
Connection cables
3
3
Solid 0.2–4.0 mm
3
3
Flexible 0.2–2.5 mm
Degree of protection IP20 IP20 IP20 IP20 IP20
3
3
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
Ambient operating temperature –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C
3
3
Transport and storage temperature –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C
Hazardous location CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
3
3
easy700 Series
3
3
Type EASY719-AB… EASY719-AC… EASY719-DA… EASY719-DC-RC… EASY721-DC-TC.
3
3
Supply voltage 24 Vac 100–240 Vac 12 Vdc 24 Vdc 24 Vdc
Heat dissipation 7 VA 10 VA 3.5 W 3.5 W 3.5 W
3
3
Continuous current outputs
Short-circuit proof with power factor 1 Line protection B16, 600 A Line protection B16, 600 A Line protection B16, 600 A Line protection B16, 600 A —
3
3
Short-circuit proof with power factor 0.7…0.7 Line protection B16, 900 A Line protection B16, 900 A Line protection B16, 900 A Line protection B16, 900 A —
Mounting On 35 mm DIN rail or screw mounting with ZB4-101-GF1 mounting feet
3
3
Connection cables
Solid 0.2–4.0 mm
3
3
Flexible 0.2–2.5 mm
3
3
Degree of protection IP20 IP20 IP20 IP20 IP20
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
3
3
Ambient operating temperature –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C
Transport and storage temperature –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C
3
3
Hazardous location CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
3
3
easy800 Series
Type EASY819-AC… EASY819-DC-RC… EASY820-DC-RC… EASY821-DC-TC… EASY822-DC-TC.
3
3
Supply voltage 100–240 Vac 24 Vdc 24 Vdc 24 Vdc 24 Vdc
3
3
Heat dissipation 10 VA 3.4 W 3.4 W 3.4 W 3.4 W
Continuous current outputs
3
3
Short-circuit proof with power factor 1 Line protection B16, 600 A Line protection B16, 600 A Line protection B16, 600 A Line protection B16, 600 A —
Short-circuit proof with power factor 0.7…0.7 Line protection B16, 900 A Line protection B16, 900 A Line protection B16, 900 A Line protection B16, 900 A —
3
3
Mounting On 35 mm DIN rail or screw mounting with ZB4-101-GF1 mounting feet
Connection cables
3
3
Solid 0.2–4.0 mm
3
3
Flexible 0.2–2.5 mm
Degree of protection IP20 IP20 IP20 IP20 IP20
3
3
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
Ambient operating temperature –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C
3
3
Transport and storage temperature –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C
Hazardous location CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
3
3
Note
1
3
3
Relay = 8 A (10 A to UL) with resistive load, 3 A with inductive load. Transistor outputs = 0.5 A/24 Vdc, maximum four outputs switchable in parallel.
Programmable Relays
1
1
1
8 A8 A8 A8 A0.5 A
8 A8 A8 A8 A0.5 A
8 A8 A8 A8 A0.5 A
2
(AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12) 0.2–4.0 mm2 (AWG 22–12)
2
(AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12) 0.2–2.5 mm2 (AWG 22–12)
V7-T3-24 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
V7-T3-24 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017
Page 7
Control Relays and Timers
2.81 (71.5)
1.41
(35.8)
3.54
(90.0)
4.02
(102.0)
4.33
(110.0)
1.97 (50.0)0.42 (10.8)
(M4)
0.157
(3.9)
Dia.
2.28 (58.0)
1.77
(45.0)
0.18 (4.5)
2.22 (56.5)
1.87 (47.5)
easy500
4.23 (107.5)
3.54
(90.0)
4.02
(102.0)
4.33
(110.0)
2.96 (75.0)0.64 (16.3) 0.64 (16.3)
(M4)
0.157
(3.9)
Dia.
easy700
2.28 (58.0)
2.22 (56.5)
1.87 (47.5)
1.77
(45.0)
0.18 (4.5)
4.23 (107.5)
3.54
(90.0)
4.02
(102.0)
4.33
(110.0)
2.96 (75.0)0.64 (16.3)
(M4)
0.157
(3.9)
Dia.
0.64 (16.3)
2.83 (72.0)
1.77
(45.0)
2.78 (70.5)
1.91 (48.5)
easy800
0.18 (4.5)
Programmable Relays
3.3
Dimensions
Approximate Dimensions in Inches (mm)
easy500 Series, Drawing Number MD05013001E
easy700 Series, Drawing Number MD05013002E
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
easy800 Series, Drawing Number MD05013003E
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-25
Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—May 2017 V7-T3-25
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Loading...