KLING & FREITAG CLUSTERPLATE CA 106 User Manual

Page 1
KLING & FREITAG CLUSTERPLATE CA 106
User’s Manual
Important Information, Please Read before Use!
KLING & FREITAG GmbH
Junkersstrasse 14 D-30179 Hannover TEL 0 (049) 511- 969 97-0 FAX 0 (049) 511- 67 37 94 www.kling-freitag.de
Page 2
User’s Manual
CA 106 Cluster Plate
Contents
Chapter
Safety instructions for speakers and assembly equipment found in safety manual supplied with equipment!
Page
Symbols in user’s manual Information about this user’s manual 2
1. Scope of delivery and definition of the various threads and drill holes 3
2. Additional mounting devices 3
3. Assembly 4
4. Operation 5-6
4.1 Mounting with various tilt angles 5
4.2 Use of mounting devices 6
5. Examples of use 6
6. Basic measurements, weight and admissible load capacity 7
Symbols in user’s manual
The following symbols in this manual are used to assist the user with the installation and assembly instructions. They are also used to draw attention to the various safety warnings
:
This warning symbol indicates possible dangerous situations resulting from improper assembly or use.
Information about the application, assembly and operation of the described products and features.
This symbol indicates important technical specifica­tions and safety instructions as well as handling and safety regulations.
Information about this user’s manual
User’s Manual CA 106 Cluster Plate, Version 1.0 06/2001 © by André Schweimler, Kling & Freitag GmbH, April 2000; all rights reserved. All specifications in this manual are based on information available at the time of publishing for the features and safety guidelines of the described products. Technical specifications, measurements, weights and properties are not guaranteed. The manufacturer reserves the right to make product alterations within legal provisions as well as changes to improve product quality.
KLING & FREITAG GMBH Junkersstr.14 D-30179 Hannover Tel: ++49 (0)511-96 99 70 Fax: ++49 (0)511-67 37 94
KLING & FREITAG GmbH
2
Page 3
User’s Manual
CA 106 Cluster Plate
1. Scope of delivery and definition of the various threads and drill holes
The CA 106 Cluster Plate is not assembled upon delivery. The following individual parts are included in the scope of delivery.
Tooth lock screws M8 x 20
CA 106 Cluster Plate Special eye bolts M8 x 20
washers and spring washers
for mounting speakers
Drill holes for mounting safety cable
Permissible mounting points for eye bolts
Mounting points for additional mounting devices such as stand and pole mout adapters
Mounting points for speakers
2. Additional mounting devices for the CA 106 Cluster Plate
Compatible stand and pole mount adapters are available for the CA 106 Cluster Plate.
Furthermore, the K&F hand wheel M8 x 20 may also be used for mobile use. These hand wheels can, however, only be used in conjunction with the supplied Ø 8,4mm washer with large outer diameter and an M8 spring washer!
Hand wheel M8 x 20
#
KLING & FREITAG GmbH
K&F stand adapter K&F pole mount adapter
3
Page 4
User’s Manual
3. Assembly
CA 106 Cluster Plate
The CA 106 Cluster Plate enables the user to mount the CA 106 next to each other in an optimally determined angle based on measurements and acoustics. Because the CA 106 is equipped with a rotating horn coverage to be adjusted as necessary, the Cluster Plate offers two different horizon­tal array possibilities. The positions of the appropriate mounting drill holes are illus­trated below.
The supplied self-locking screws should be screwed through the appropriate mounting drill holes on the Cluster Plate into both threads on the top or bottom of the CA 106. The bolts should be screwed in tightly. If the mounted speaker is to have a tilt angle of 15°, then the supplied special eye bolts M8 x 20 should be screwed into the back thread of the plate (see also following page).
Only use the supplied special eye bolts M8 x 20. When used in conjunction with the safety equipment (spring washers and washers), the thread on other commercial eye bolts is too short to ensure safe assembly!
The CA 106 Cluster Plate should always be flown by using at least two eye bolts. When securing the eye bolts, always use additional washers and spring washers to prevent the bolts from loosening.
which enables the speakers’
Mounting drill holes for horn position with coverage: hor. 90° / vert.60°
Hor. total coverage: 150°
Mounting drill holes for horn position with coverage: hor. 60° / vert.90°
KLING & FREITAG GmbH
Hor. total coverage: 100°
4
Page 5
User’s Manual
4. Operation
4. 1 Mounting with various tilt angles
Hanging the assembled speakers without vertical tilt:
Hanging the assembled speakers with vertical tilt of 15°:
Always use additional washers and spring washers when securing eye bolts.
CA 106 Cluster Plate
Hanging the assembled speakers with vertical tilt of 30°:
Hanging the assembled speakers with vertical tilt of >30°:
KLING & FREITAG GmbH
5
Page 6
User’s Manual
4.2 Use of mounting devices
The CA 106 Cluster Plate can be equipped with mounting devices such as a pole mount adapters to hang speakers from a pole mount or with a stand adapter for mounting on a stand. Pole mount adapter and stand adapter should be screwed onto the threads on the axis using self-locking screws or a hand wheel M8 x 20, respectively, with spring washer and washer.
When using a pole mount, place the threaded bolt of the pole mount through the drill hole in the middle of the pole mount adapter. Screw the pole mount tightly using a self-locking screw nut M10.
Consult the safety instructions of the mounting equipment and material for indica­tions for proper use and load capacity!
The structure must be additionally secured with a safety cable connected to an
external point to prevent falling down!
Secure all screwed connections on the tilt brackets and ring lugs to prevent loosening by using, i.e., self-locking nuts, tooth lock washer, spring washer, etc.
5. Examples of use
CA 106 Cluster Plate
Ca 106 Cluster Plate with pole mount, pole mount adapter, and pipe clamp on pipe
Ca 106 Cluster Plate on ring lug “flown“ with 30° tilt
Ca 106 Cluster Plate on speaker stand
KLING & FREITAG GmbH
6
Page 7
User’s Manual
6. Basic measurements, weight and working load limit
CA 106 Cluster Plate
52mm
200mm
CA 106 Cluster Plate
21mm
324mm
Weight: 1,7kg
Working load limit (WLL): 18kg
The CA 106 Cluster Plate is designed having sufficient size and strength to fulfill the requirements of use in the described applications. The CA 106 Cluster Plate may only be used for applications indicated and in the manner described in this manual. The non-observance of these specifications may cause the mechanical load capacity of the CA 106 Cluster Plate or of the speaker enclosure to be exceeded. Only the sup­plied equipment should be used for assembly. The use of other equipment – espe­cially equipment from other manufacturers – is not authorized.
The CA 106 Cluster Plate is designed to mount two speakers! The admissible load capacity of the mounting devices should never be exceeded.
Only use official equipment from Kling&Freitag.
The CA 106 Cluster Plate should not, under any circumstances, be used to hang up any other objects or in conjunction with speaker systems other than those described here!
KLING & FREITAG GmbH
7
Loading...