Safety instructions for speakers and assembly equipment found in safety
manual supplied with equipment!
Page
Symbols in user’s manual
Information about this user’s manual 2
1. Scope of delivery and definition of the various threads and drill holes 3
2. Additional mounting devices 3
3. Assembly 4
4. Operation 5-6
4.1 Mounting with various tilt angles 5
4.2 Use of mounting devices 6
5. Examples of use 6
6. Basic measurements, weight and admissible load capacity 7
Symbols in user’s manual
The following symbols in this manual are used to assist the user with the installation and assembly instructions.
They are also used to draw attention to the various safety warnings
:
This warning symbol indicates possible dangerous
situations resulting from improper assembly or
use.
Information about the application, assembly and
operation of the described products and features.
This symbol indicates important technical specifications and safety instructions as well as handling
and safety regulations.
1. Scope of delivery and definition of the various threads and drill holes
The CA 106 ClusterPlate is not assembled upon delivery. The following individual parts are included in the
scope of delivery.
Tooth lock screws M8 x 20
CA 106 ClusterPlateSpecial eye bolts M8 x 20
washers and
spring washers
for mounting speakers
Drill holes for
mounting
safety cable
Permissible mounting
points for eye bolts
Mounting points for
additional mounting devices
such as stand and
pole mout adapters
Mounting
points for
speakers
2. Additional mounting devices for the CA 106 ClusterPlate
Compatible stand and pole mount adapters are available for the CA 106 Cluster
Plate.
Furthermore, the K&F hand wheel M8 x 20 may also be used for mobile use. These
hand wheels can, however, only be used in conjunction with the supplied Ø 8,4mm
washer with large outer diameter and an M8 spring washer!
Hand wheel M8 x 20
#
KLING & FREITAG GmbH
K&F stand adapterK&F pole mountadapter
3
Page 4
User’s Manual
3. Assembly
CA 106 Cluster Plate
The CA 106 ClusterPlate enables the user to mount the CA 106 next to each other
in an optimally determined angle based on measurements and acoustics.
Because the CA 106 is equipped with a rotating horn
coverage to be adjusted as necessary, the ClusterPlate offers two different horizontal array possibilities. The positions of the appropriate mounting drill holes are illustrated below.
The supplied self-locking screws should be screwed through the appropriate
mounting drill holes on the ClusterPlate into both threads on the top or bottom of
the CA 106. The bolts should be screwed in tightly. If the mounted speaker is to
have a tilt angle of 15°, then the supplied special eye bolts M8 x 20 should be
screwed into the back thread of the plate (see also following page).
Only use the supplied special eye bolts M8 x 20. When used in conjunction
with the safety equipment (spring washers and washers), the thread on
other commercial eye bolts is too short to ensure safe assembly!
The CA 106 ClusterPlate should always be flown by using at least two eye
bolts. When securing the eye bolts, always use additional washers and
spring washers to prevent the bolts from loosening.
which enables the speakers’
Mounting drill holes for horn position
with coverage: hor. 90° / vert.60°
Hor. total coverage: 150°
Mounting drill holes for horn position
with coverage: hor. 60° / vert.90°
KLING & FREITAG GmbH
Hor. total coverage: 100°
4
Page 5
User’s Manual
4. Operation
4. 1 Mounting with various tilt angles
Hanging the assembled speakers without vertical tilt:
Hanging the assembled speakers with vertical tilt of 15°:
Always use additional washers and spring washers when securing eye bolts.
CA 106 Cluster Plate
Hanging the assembled speakers with vertical tilt of 30°:
Hanging the assembled speakers with vertical tilt of >30°:
KLING & FREITAG GmbH
5
Page 6
User’s Manual
4.2 Use of mounting devices
The CA 106 ClusterPlate can be equipped with mounting devices such as a pole
mount adapters to hang speakers from a pole mount or with a stand adapter for
mounting on a stand. Pole mount adapter and stand adapter should be screwed
onto the threads on the axis using self-locking screws or a hand wheel M8 x 20,
respectively, with spring washer and washer.
When using a pole mount, place the threaded bolt of the pole mount through the
drill hole in the middle of the pole mount adapter. Screw the pole mounttightly
using aself-locking screw nut M10.
Consult the safety instructions of the mounting equipment and material for indications for proper use and load capacity!
The structure must be additionally secured with a safety cable connected to an
external point to prevent falling down!
Secure all screwed connections on the tilt brackets and ring lugs to prevent
loosening by using, i.e., self-locking nuts, tooth lock washer, spring washer,
etc.
5. Examples of use
CA 106 Cluster Plate
Ca 106 ClusterPlate with pole
mount, pole mount adapter,
and pipe clamp on pipe
Ca 106 ClusterPlate on ring lug
“flown“ with 30° tilt
Ca 106 ClusterPlate on speaker
stand
KLING & FREITAG GmbH
6
Page 7
User’s Manual
6. Basic measurements, weight and working load limit
CA 106 ClusterPlate
52mm
200mm
CA 106 Cluster Plate
21mm
324mm
Weight: 1,7kg
Working load limit (WLL): 18kg
The CA 106 ClusterPlate is designed having sufficient size and strength to fulfill the
requirements of use in the described applications. The CA 106 ClusterPlate may only
be used for applications indicated and in the manner described in this manual. The
non-observance of these specifications may cause the mechanical load capacity of
the CA 106 ClusterPlate or of the speaker enclosure to be exceeded. Only the supplied equipment should be used for assembly. The use of other equipment – especially equipment from other manufacturers – is not authorized.
The CA 106 ClusterPlate is designed to mount two speakers! The admissible load
capacity of the mounting devices should never be exceeded.
Only use official equipment from Kling&Freitag.
The CA 106 ClusterPlate should not, under any circumstances, be used to hang up
any other objects or in conjunction with speaker systems other than those described
here!