KLING & FREITAG ACCESS T5, ACCESS T9, ACCESS B5, ACCESS B10 Operating Instructions Manual

Operating Instructions
T r a n s l a t io n of t he or i g i n a l i ns tr uc ti on
Important Information, Please Read Before Use!
KLING & FREITAG GmbH Junkersstrasse 14 D-30179 Hannover TEL +49 (0) 511- 969 97-0 FAX +49 (0) 511- 67 37 94 www.kling-freitag.de
Version 6.3
Released: 6.12.2016
K&F ACCESS Controller P.A. im ‚True Array Design‘
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 2 of 2
ACCESS SYSTEM
Thank you for your decision to buy a KLING & FREITAG product. To guarantee a trouble-free operating of the equipment and to enable the KLING & FREITAG ACCESS System to achieve its full potential, please read the operating instruc­tions carefully before use.
With the purchase of an ACCESS System, you have acquired a speaker system with the highest possible quality and performance capabilities.
As the owner of this system, you now have a versatile and highly professional tool which, when operated properly, is a true pleasure to use.
Symbols in User's Manual
Warning
This symbol indicates the possibility of life-threatening danger and a health risk for persons. Not following these instructions may result in serious health problems including potentially fatal injuries.
Caution
This symbol indicates a possibly dangerous situation. Not following these instructions may cause minor injuries or property damage.
Important
This symbol gives instructions for the proper use of the described prod­ucts. Not following these instructions may cause malfunctions or proper­ty damage.
Information about this User's Manual
User's Manual ACCESS System Version 6.0, 06.12.2016 © by André Figula, Kling & Freitag GmbH, 1995 - 2016; all rights reserved. All specifications in this manual are based on information available at the time of pub-
lishing for the features and safety guidelines of the described products. Technical specifications, dimensions, weights and properties are not guaranteed. The manufacturer reserves the right to make product alterations within legal provisions
as well as changes to improve product quality.
All persons who use the speaker system must have this guide and all further information for safe operations available to them during assembly, disassem­bly, and use.
We appreciate any input with suggestions and improvements for this manual. Please send this to us at the following address:
info@kling-freitag.de or to: KLING & FREITAG GMBH Junkersstr.14 D-30179 Hannover Phone +49 (0) 511 - 96 99 70 Fax +49 (0) 511 - 67 37 94
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 3 of 3
Contents
Chapter Page
1. General Safety Instructions for Using Speakers
General Safety Instructions for Using SpeakersGeneral Safety Instructions for Using Speakers
General Safety Instructions for Using Speakers 5
2. The ACCESS System Components
The ACCESS System ComponentsThe ACCESS System Components
The ACCESS System Components 7
3. The Top Speakers
The Top SpeakersThe Top Speakers
The Top Speakers 9
3.1
3.13.1
3.1 T5 Mid/High System
T5 Mid/High SystemT5 Mid/High System
T5 Mid/High System 9
3.1.1 T5 Applications
T5 ApplicationsT5 Applications
T5 Applications 9999
3.1.2 T5 Technical Specifications
T5 Technical SpecificationsT5 Technical Specifications
T5 Technical Specifications 9999
3.1.3 T5 Measuring Charts
T5 Measuring ChartsT5 Measuring Charts
T5 Measuring Charts 10
1010
10
3.1.4 T5 Dimensions
T5 DimensionsT5 Dimensions
T5 Dimensions 10
1010
10
3.2
3.23.2
3.2 T9 Mid/High System
T9 Mid/High SystemT9 Mid/High System
T9 Mid/High System 11
3.2.1 T9 Applications
T9 ApplicationsT9 Applications
T9 Applications 11
1111
11
3.2.2 T9 Technical Specifications
T9 Technical SpecificationsT9 Technical Specifications
T9 Technical Specifications 11
1111
11
3.2.3 T9 Measuring Charts
T9 Measuring ChartsT9 Measuring Charts
T9 Measuring Charts 12
1212
12
3.2.4 T9 Dimensions
T9 DimensionsT9 Dimensions
T9 Dimensions 12
1212
12
4. The Subwoofers
The SubwoofersThe Subwoofers
The Subwoofers 13
4.1
4.14.1
4.1 Short
ShortShort
Short----Circuit Fuses in the K&F Subwoofer Sys
Circuit Fuses in the K&F Subwoofer SysCircuit Fuses in the K&F Subwoofer Sys
Circuit Fuses in the K&F Subwoofer Sys tems
temstems
tems 13
4.1.1 Risks of using High Performance Power Amplifiers
Risks of using High Performance Power AmplifiersRisks of using High Performance Power Amplifiers
Risks of using High Performance Power Amplifiers 13
1313
13
4.1.2 Identifying the Models with Short
Identifying the Models with ShortIdentifying the Models with Short
Identifying the Models with Short----Circuit Fuses
Circuit FusesCircuit Fuses
Circuit Fuses 13
1313
13
4.1.3 Add
AddAdd
Add----On Kits for Subwoofers without Short
On Kits for Subwoofers without ShortOn Kits for Subwoofers without Short
On Kits for Subwoofers without Short----Circuit
Circuit Circuit
Circuit Fuses
FusesFuses
Fuses 13
1313
13
4.1.4 Specification of the Fuses
Specification of the FusesSpecification of the Fuses
Specification of the Fuses 14
1414
14
4.1.5 Replacement and Positions of the Short
Replacement and Positions of the ShortReplacement and Positions of the Short
Replacement and Positions of the Short----Circuit Fuses
Circuit FusesCircuit Fuses
Circuit Fuses 14
1414
14
4.2
4.24.2
4.2 B5 Subwoofer System, Specifications
B5 Subwoofer System, SpecificationsB5 Subwoofer System, Specifications
B5 Subwoofer System, Specifications 15
4.2.1 B5 Applications
B5 ApplicationsB5 Applications
B5 Applications 15
1515
15
4.2.2 B5 Technical Specifications
B5 Technical SpecificationsB5 Technical Specifications
B5 Technical Specifications 15
1515
15
4.2.3 B5 Measuring Charts
B5 Measuring ChartsB5 Measuring Charts
B5 Measuring Charts 16
1616
16
4.2.4 B5 Dimensions
B5 DimensionsB5 Dimensions
B5 Dimensions 16
1616
16
4.3
4.34.3
4.3 B10 Subwoofer System
B10 Subwoofer SystemB10 Subwoofer System
B10 Subwoofer System 17
4.3.1 B10 Applications
B10 ApplicationsB10 Applications
B10 Applications 17
1717
17
4.3.2 B10 Technical Specifications
B10 Technical SpecificationsB10 Technical Specifications
B10 Technical Specifications 17
1717
17
4.3.3 B10 Measuring Charts
B10 Measuring ChartsB10 Measuring Charts
B10 Measuring Charts 18
1818
18
4.3.4 B10 Dimensions
B10 DimensionsB10 Dimensions
B10 Dimensions 18
1818
18
4.4
4.44.4
4.4 Using the ACCES
Using the ACCESUsing the ACCES
Using the ACCESS B5 / B10 with other K&F Systems
S B5 / B10 with other K&F SystemsS B5 / B10 with other K&F Systems
S B5 / B10 with other K&F Systems 19
5. Pin Diagrams of Connectors and internal Wiring
Pin Diagrams of Connectors and internal WiringPin Diagrams of Connectors and internal Wiring
Pin Diagrams of Connectors and internal Wiring 19
5.1
5.15.1
5.1 ACCESS T5 Pin Diagrams of Connectors and Wiring
ACCESS T5 Pin Diagrams of Connectors and WiringACCESS T5 Pin Diagrams of Connectors and Wiring
ACCESS T5 Pin Diagrams of Connectors and Wiring 19
5.2
5.25.2
5.2 ACCESS T9 Pin Diagrams of Con
ACCESS T9 Pin Diagrams of ConACCESS T9 Pin Diagrams of Con
ACCESS T9 Pin Diagrams of Connectors and Wiring
nectors and Wiringnectors and Wiring
nectors and Wiring 19
5.3
5.35.3
5.3 ACCESS B5 Pin Diagrams of Connectors
ACCESS B5 Pin Diagrams of ConnectorsACCESS B5 Pin Diagrams of Connectors
ACCESS B5 Pin Diagrams of Connectors 20
5.4
5.45.4
5.4 ACCESS B10 Pin Diagrams of Connectors
ACCESS B10 Pin Diagrams of ConnectorsACCESS B10 Pin Diagrams of Connectors
ACCESS B10 Pin Diagrams of Connectors 20
6. Safety Instructions for Controller and Connector Panel
Safety Instructions for Controller and Connector PanelSafety Instructions for Controller and Connector Panel
Safety Instructions for Controller and Connector Panel 21
7. K&F CD 44 Digital System Controller
K&F CD 44 Digital System ControllerK&F CD 44 Digital System Controller
K&F CD 44 Digital System Controller 22
8. The ACCESS Controllers
The ACCESS ControllersThe ACCESS Controllers
The ACCESS Controllers 22
8.1
8.18.1
8.1 The ACCESS C5/9 Controller
The ACCESS C5/9 ControllerThe ACCESS C5/9 Controller
The ACCESS C5/9 Controller 23
8.1.1 Connectors, Controls and Displays and of the C5/9
Connectors, Controls and Displays and of the C5/9Connectors, Controls and Displays and of the C5/9
Connectors, Controls and Displays and of the C5/9 23
2323
23
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 4 of 4
8.1.2 C5/9 Controller Technical Specifications
C5/9 Controller Technical SpecificationsC5/9 Controller Technical Specifications
C5/9 Controller Technical Specifications 25
2525
25
8.1.3 Pin Diagrams of the C5/9 Controller's In
Pin Diagrams of the C5/9 Controller's InPin Diagrams of the C5/9 Controller's In
Pin Diagrams of the C5/9 Controller's In---- and Outputs
and Outputsand Outputs
and Outputs 25
2525
25
8.2
8.28.2
8.2 The ACCE
The ACCEThe ACCE
The ACCESS C10 Controller
SS C10 ControllerSS C10 Controller
SS C10 Controller 26
8.2.1 Connectors, Controls and Displays and of the C10
Connectors, Controls and Displays and of the C10Connectors, Controls and Displays and of the C10
Connectors, Controls and Displays and of the C10 26
2626
26
8.2.2 C10 Controller Technical Specifications
C10 Controller Technical SpecificationsC10 Controller Technical Specifications
C10 Controller Technical Specifications 29
2929
29
8.2.3 Pin Diagrams C10 Controller In
Pin Diagrams C10 Controller InPin Diagrams C10 Controller In
Pin Diagrams C10 Controller In---- and Outputs
and Outputsand Outputs
and Outputs 29
2929
29
9. The ACCESS Connector Panels
The ACCESS Connector PanelsThe ACCESS Connector Panels
The ACCESS Connector Panels 30
9.1
9.19.1
9.1 Connectors of the Connector Panels CP1 and CP3
Connectors of the Connector Panels CP1 and CP3Connectors of the Connector Panels CP1 and CP3
Connectors of the Connector Panels CP1 and CP3 30
9.1.1 Connector Panel CP1 und CP3 Technical Specifications
Connector Panel CP1 und CP3 Technical SpecificationsConnector Panel CP1 und CP3 Technical Specifications
Connector Panel CP1 und CP3 Technical Specifications 31
3131
31
9.1.2 CP1 and CP3 Pin Diagrams of In
CP1 and CP3 Pin Diagrams of InCP1 and CP3 Pin Diagrams of In
CP1 and CP3 Pin Diagrams of In---- and Outputs
and Outputsand Outputs
and Outputs 32
3232
32
9.2
9.29.2
9.2 Connectors of the Bass Connector Panels CP1
Connectors of the Bass Connector Panels CP1Connectors of the Bass Connector Panels CP1
Connectors of the Bass Connector Panels CP1----B und CP3
B und CP3B und CP3
B und CP3----BBBB 33
9.2.1 Connector Panel CP1
Connector Panel CP1Connector Panel CP1
Connector Panel CP1----B und CP3
B und CP3B und CP3
B und CP3----B Technical Specifications
B Technical SpecificationsB Technical Specifications
B Technical Specifications 34
3434
34
9.2.2 CP1
CP1CP1
CP1----B and CP3
B and CP3B and CP3
B and CP3----B Pin Diagrams of In
B Pin Diagrams of InB Pin Diagrams of In
B Pin Diagrams of In---- and Outputs
and Outputsand Outputs
and Outputs 35
3535
35
10. Connecting Instructions for the ACCESS System
Connecting Instructions for the ACCESS SystemConnecting Instructions for the ACCESS System
Connecting Instructions for the ACCESS System 36
10.1
10.110.1
10.1 Wiring
WiringWiring
Wiring 36
10.2
10.210.2
10.2 Avoiding Ground Loops
Avoiding Ground LoopsAvoiding Ground Loops
Avoiding Ground Loops 37
10.2.1 What is a Ground Loop?
What is a Ground Loop?What is a Ground Loop?
What is a Ground Loop? 37
3737
37
10.2.2 Avoiding Ground Loops
Avoiding Ground LoopsAvoiding Ground Loops
Avoiding Ground Loops 37
3737
37
11. Recommended Amplifier Performance for the ACCESS System
Recommended Amplifier Performance for the ACCESS SystemRecommended Amplifier Performance for the ACCESS System
Recommended Amplifier Performance for the ACCESS System 38
11.1
11.111.1
11.1 Correct Bass and Top Speaker Ratio
Correct Bass and Top Speaker RatioCorrect Bass and Top Speaker Ratio
Correct Bass and Top Speaker Ratio 39
12. Mounting Instructions for Loudspeakers
Mounting Instructions for LoudspeakersMounting Instructions for Loudspeakers
Mounting Instructions for Loudspeakers 40
12.1
12.112.1
12.1 Mounting and Stacking the ACCESS Systems
Mounting and Stacking the ACCESS SystemsMounting and Stacking the ACCESS Systems
Mounting and Stacking the ACCESS Systems 41
12.2
12.212.2
12.2 Using the MAN Rigging Points
Using the MAN Rigging PointsUsing the MAN Rigging Points
Using the MAN Rigging Points 42
13. Operating the
Operating the Operating the
Operating the ACCESS SYSTEM
ACCESS SYSTEMACCESS SYSTEM
ACCESS SYSTEM 43
14. Connection Diagrams
Connection DiagramsConnection Diagrams
Connection Diagrams 44
14.1
14.114.1
14.1 ACCESS System with Controller C5/9 and CP1/3
ACCESS System with Controller C5/9 and CP1/3ACCESS System with Controller C5/9 and CP1/3
ACCESS System with Controller C5/9 and CP1/3 44
14.2
14.214.2
14.2 ACCESS System with Controller C5/9, no Connector Panel
ACCESS System with Controller C5/9, no Connector PanelACCESS System with Controller C5/9, no Connector Panel
ACCESS System with Controller C5/9, no Connector Panel 45
14.3
14.314.3
14.3 Optimised Operations with B10, C10 and CP1/3
Optimised Operations with B10, C10 and CP1/3Optimised Operations with B10, C10 and CP1/3
Optimised Operations with B10, C10 and CP1/3----BBBB 46
14.4
14.414.4
14.4 Optimised Operations with B10, C10 without CP1/3
Optimised Operations with B10, C10 without CP1/3Optimised Operations with B10, C10 without CP1/3
Optimised Operations with B10, C10 without CP1/3----BBBB 47
15. Sound Pressure Dispersion of Mid
Sound Pressure Dispersion of MidSound Pressure Dispersion of Mid
Sound Pressure Dispersion of Mid----High Systems T5 & T9
High Systems T5 & T9High Systems T5 & T9
High Systems T5 & T9 48
15.1
15.115.1
15.1 Sound Pressure Dispersion of combined Mid
Sound Pressure Dispersion of combined MidSound Pressure Dispersion of combined Mid
Sound Pressure Dispersion of combined Mid----High Systems
High SystemsHigh Systems
High Systems 49
15.2
15.215.2
15.2 Sound Pressure Dispersion in Relation to the Position
Sound Pressure Dispersion in Relation to the PositionSound Pressure Dispersion in Relation to the Position
Sound Pressure Dispersion in Relation to the Position 50
16. Basic Rules for the Alignment of the ACCESS Systems
Basic Rules for the Alignment of the ACCESS SystemsBasic Rules for the Alignment of the ACCESS Systems
Basic Rules for the Alignment of the ACCESS Systems 51
17. Examples of Configurations and Applications
Examples of Configurations and ApplicationsExamples of Configurations and Applications
Examples of Configurations and Applications 53
18. Accessories for the ACCESS System
Accessories for the ACCESS SystemAccessories for the ACCESS System
Accessories for the ACCESS System 58
19. Regulations for Disposal
Regulations for DisposalRegulations for Disposal
Regulations for Disposal 60
19.1
19.119.1
19.1 Germany:
Germany:Germany:
Germany: 60
19.2
19.219.2
19.2 EU, Norway, Island, and Liechtenstein (not Germany):
EU, Norway, Island, and Liechtenstein (not Germany):EU, Norway, Island, and Liechtenstein (not Germany):
EU, Norway, Island, and Liechtenstein (not Germany): 60
19.3
19.319.3
19.3 Other countries
Other countriesOther countries
Other countries 60
20. Included Safety and Mounting Instructions for Loudspeakers and Accessories
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 5 of 5
1. General Safety Instructions for Using Speakers
Mounting the speakers
To prevent injury or property damage, this equipment must be securely placed on the floor or mounted in a different manner according to the mounting instructions on page 40 (Mounting Instructions for Loudspeakers). Speakers, which are stacked, must be secured
with safety straps. Please note that speakers can move as a result of vibrations. To pre­vent them from falling from their mounted position, they must be secured properly. If the weight of the speaker exceeds 20 kg then it is necessary for two people to carry it. Speakers may only be mounted to walls and ceilings by qualified personnel. The speak­ers must be hung by using the two designated MAN flying points on the sides of the speaker. The same applies when lifting and aligning the speakers. Only connections designed to fit the flying points should be used. If in doubt, please consult the manufac­turer.
The bass system ACCESS B10 is not designed for flown applications. Never use signal cables or power cords for suspending, aligning or securing the systems. When laying the connecting cables, make sure that nobody can trip. Never hang more than two speakers under one another without using the designated Kling & Freitag rigging equipment. Ensure that all installation connections comply with the applicable safety guidelines and that the size and strength are sufficient. Further instructions are in our user's manual for assembly equipment and in the general safety instructions for speakers and accessories. For mobile and fixed installations, use only mounting accessories from Kling & Freitag, if possible. Speakers and mounting accessories must be visually examined at regular intervals. If there are signs of wear, they must be replaced immediately. Furthermore, screwed con­nections of supporting parts must be checked routinely.
Protecting the speakers / avoiding fire hazard
In general, audio signals should not be overdriven. This may be caused by mixing consoles, equalizers, effect equipment, etc. and should be indicated on this equipment. When a power amplifier is overloaded at the output (clipping), then the amplifier should activate a clipping warning signal. Power amplifiers can also be overloaded at the input circuit without the amplifier signalling the clipping, i.e. when there is not sufficient headroom in the input cir­cuit. We, therefore, recommend turning up the power amplifiers all the way and adjusting the level before the power amplifier in order to avoid overloading the input circuit. In any case, the signal must be reduced as soon as it sounds unnaturally distorted.
To protect the speakers from being destroyed and to avoid fire hazard, they should
only be operated with professional power amplifiers with the following specifications:
Amplification according to the instructions in the chapter Recommended Amplifier
Performance for the ACCESS System from page 38 onwards.
Integrated clipping limiter
without using a Kling & Freitag controller (not recommended):
Integrated or preceding subsonic filter (approx. 20 Hz, min. 12 dB / octave) Power amplifiers with power specifications lower than those stated from page 39 onwards must be supplied with a clip limiter for speaker protection, even if they are operated with a Kling & Freitag system controller.
If you wish to use a speaker with a power amplifier that does not fulfil these specifications, then the speaker should be controlled using a Kling & Freitag system controller with limiter function. This is the only way overloading and the risk of fire can be avoided. The results of such a power amplifier defect cannot be avoided by the controller.
For damage caused by overloading or use with power amplifiers other than those rec­ommended above or with amplifiers with higher output power, Kling & Freitag GmbH does not assume warranty and excludes liability for possible consequential damage.
Warning
Warning
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 6 of 6
The following signals may damage the speakers
permanent high-pitched signals with high frequency and continuous noise from
feedback.
permanently distorted signals with high power.
noises, which occur when the amplifier is on while equipment is being connected,
disconnected or switched on.
Do not install speakers in any of the following places:
where the speakers are permanently exposed to direct sunlight
where the speakers are exposed to high moisture or rain
where the speakers are exposed to strong vibrations and dust.
Damage caused by the speakers' magnetic fields
Speakers are permanently surrounded by a magnetic field, even when they are not op­erating. Therefore, during transport and placement of the speakers, it is important to ensure that there is always approx. 1 m between the speakers and magnetic data media and computer/video monitors.
Preventing hearing damage
To prevent the risk of hearing damage, avoid being too close to operating speakers, even if the volume level seems to be low enough. In general, volume levels over 90 dB can cause hearing damage.
Important
Caution
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 7 of 7
2. The ACCESS System Components
The ACCESS SYSTEM consists of the perfectly tuned system components including speakers, system controllers and connector panels. This manual describes up through and including chapter 8 each individual component. Subsequently, connecting instruc­tions and system configurations are mentioned and explained based on example.
ACCESS Mid-High Systems:
ACCESS T5
Description as of page 9
ACCESS T9
Description as of page 11
ACCESS Bass Systems:
ACCESS B5
Description as of page 15
ACCESS B10
Description as of page 17
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 8 of 8
ACCESS System Controller:
System Controller ACCESS C5/9 Description as of page 23
CLUSTER
SINGLE
8
HIGH BOOST
NORMAL
ACCES
S
C5/9
0
+6
LEVEL
CLIP
dB
SENSE (GREEN) / LIMIT (RED)
H
I
G
H
+
10
d
B
INPUT SIGNAL
-40
dB
0
dB
MID
E
XCURS
I
O
N
B
A
SS
O
N
POWER
ACCESS
SYSTEMCONTROLLER
System Controller ACCESS C10 Description as of page 26
CLUSTER
SINGLE
8
HIGH BOOST
NORMAL
ACCES
S
C5/9
0
+6
LEVEL
CLIP
dB
SENSE (GREEN) / LIMIT (RED)
H
I
G
H
+
10 d
B
INPUT SIGNAL
-40
d
B
0 dB
MIDE
XC
U
R
S
I
O
N
BASS
O
N
POWER
ACCESS
SYSTEMCONTROLLER
Connector Panels:
Connector Panel CP1 / CP3 for operations with the ACCESS C5/9 Controller. Description as of page 30
3
BASS SPEAKER OUT
INPUT LINK BASS OUT
GROUND ON OFF
TOP SPEAKER OUT MAINS
ACCES S
L 1
N
L 2
L 3
Connector Panel CP1-B / CP3-B for operations with the ACCESS C10 Controller Description as of page 33
BASS SPEAKER OUT
231
NEUTRIK
PUSH
132
NEUTRIK
INPUT LINK BASS OUT
GROUND ON OFF
MAINS
ACCESS
L 1
N
L 2
L 3
1
234
5
231
NEUTRIK
PUSH
132
NEUTRIK
132
NEUTRIK
1
234
5
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 9 of 9
3. The Top Speakers
3.1 T5 Mid/High System
3.1.1 T5 Applications
The ACCESS T5 is a horn-loaded high-end sound system with a consistent and homo­geneous dispersion pattern of 50° x 40°, and is, therefore, predestined for use in clus­ters and arrays. The areas of use range from discotheques and live sound coverage to large events and mega open-airs. The T5 meets all demands at the highest level --- from techno to classic. With wide-band highest sound pressure levels exceeding 140 dB and an optimal audio quality, a minimum number of units is necessary. This allows for max­imum efficiency for set-up and dismantling.
3.1.2 T5 Technical Specifications
Design 2-way horn loaded Frequency response -10 dB 100 Hz - 20 kHz (with Controller C5/9) Frequency response ± 3 dB 130 Hz - 19 kHz (with Controller C5/9) Nominal coverage angle 50° x 40° (hor. x vert.) Directivity index (DI) 14 (+1.5/-2) 630 Hz - 16 kHz Nominal power handling 500 W low-mid, 120 watts mid-high Sensitivity 1 W/1 m 110 dB low-mid, 113 dB mid-high Max. SPL 143 dB (SPL peak/1 m) Components 12" chassis with conical horn 5" compression driver with CD horn / 12‘‘ diaphragm
1.5" compression driver with CD horn / 3“ diaphragm
Crossover All-pass filter optimises phase response and delay time between the 5’’ and 12’’ driver Impedance
5 low-mid, 10 mid-high
Connectors EP-5 male / female MID: 1+ / 2-, HIGH: 3- / 4+ Enclosure Trapezoid with 2 cluster angles 4°/15° 15 mm birch plywood with highly resistant black structured paint 4 ergonomic butterfly handles 4 100 mm transport castors mounted on the rear, ball proof front grille with exchangeable black acoustic foam Rigging 2 MAN CF4T rigging points, 2 MAN HWKB strap attachments for securing straps Dimensions 600 x 900 x 750 mm without castors (W x H x D) Weight incl. Castors 92 kg Options Transport cover with butterfly catches,
MAN/K&F flying hardware, ATM modular cradle system, special finish in RAL colours, All Weather / Outdoor version
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 10 of 10
3.1.3 T5 Measuring Charts
Frequency response
on axis
with Controller C5/9
Q-Index
Beamwidth
Vertical frequency response “ off axis down “
Vertical frequency response “off axis up “
Horizontal frequency response
off axis
All m easur ement s: Far field c onditio ns. Fr equen cy reso nse 1 /6 octa ve ave raged , pola r and d irectiv ity dat a 1/3 octav e aver aged. Kling & Fre itag res erves the r ight to chan ge all specif icatio ns with out no tice. W e are not lia ble fo r misp rints.
20 100 1000 10000 20000
-30
-20
-10
0
10
Attenuation (dB)
Frequency (Hz)
0° 10° 20° 30° 40°
100 1000 10000 20000
0° 10° 20° 30° 40°
Frequency (Hz)
20
-30
-20
-10
0
10
Attenuation (dB)
20
20 100 1000 10000 20000
1
10
100
Directivity Factor (Q)
Directivity Index (DI), dB
Frequency (Hz)
0
10
Frequency (Hz)
-10
0
10
Attenuation (dB)
100 1000 10000 20000
0° 10° 20° 30° 40°
20
-30
-20
20 100 1000 10000 20000
-30
0
Frequency(Hz)
dB
3,16
31,6
316
Impedance (Ohm)
100
-20
-10
10
10
Normal HighBoost
20
-6dB Beamwidth (degr
ees)
100 1000 10000 20000
Frequency (Hz)
0
60
120
180
240
300
360
Horizontal Vertical
3.1.4 T5 Dimensions
Front View
Top View
15°
4
600 mm
Bottom View
Sliders
Plastic
588 mm
MAN Flying Point CF4T
307 mm
Side View
900 mm
421 mm
750 mm
639 mm
Rear View
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 11 of 11
3.2 T9 Mid/High System
3.2.1 T9 Applications
The ACCESS T5 is a horn-loaded high-end sound system with a consistent and homo­geneous dispersion pattern of 90° x 40°. It is, therefore, extremely well suited for small to medium coverage requirements with just one system per side such as live concerts in clubs and sound coverage in discotheques. By using pair clusters with another T9 or large arrays with the fully compatible T5, it is possible to use the equipment at large events and mega open-air concerts. The T9 meets all demands at the highest level --­from techno to classic. With wideband highest sound pressure up to 139 dB and an optimal audio quality, a minimum number of units is necessary. This allows for maxi­mum efficiency for set-up and dismantling.
3.2.2 T9 Technical Specifications
Design 2-way horn loaded Frequency response -10 dB 100 Hz - 19 kHz (with Controller C5/9) Frequency response ± 3 dB 130 Hz - 17 kHz (with Controller C5/9) Nominal coverage angle 90° x 40° (hor. x vert.) Directivity index (DI) 12 (+1.5/-1.5) 500 Hz - 20 kHz Nominal power handling 500 watts low-mid, 120 watts mid-high Sensitivity 1 W/1 m 108 dB low-mid, 110 dB mid-high Max. SPL 139 dB (SPL peak/1 m) Components 12" chassis with conical horn 5" compression driver with CD horn / 12‘‘ diaphragm
1.5" compression driver with CD horn / 3“ diaphragm
Crossover All-pass filter optimises phase response and delay time between the 5’’ and 12’’ driver Impedance
5 low-mid, 10 mid-high
Connectors EP-5 male / female MID: 1+ / 2-, HIGH: 3- / 4+ Enclosure Trapezoid with 2 cluster angles 4°/15° 15 mm birch plywood with highly resistant black structured paint 4 ergonomic butterfly handles 4 100 mm transport castors mounted on the rear,
ball proof front grille with exchangeable black acoustic foam
Rigging 2 MAN CF4T flying points, 2 MAN HWKB strap attachments for securing straps Dimensions 600 x 900 x 750 mm without castors (W x H x D) Weight incl. Castors 92 kg Options Transport cover with butterfly catches,
MAN/K&F flying hardware, ATM modular cradle system, special finish in RAL colours, All Weather / Outdoor version
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 12 of 12
3.2.3 T9 Measuring Charts
Frequency response
on axis
with Controller C5/9
Q-Index
Beamwidth
Vertical frequency response “ off axis down “
Vertical frequency response “off axis up “
Horizontal frequency response
off axis
All m easur ement s: Far field c onditio ns. Fr equen cy reso nse 1/ 6 octa ve ave raged , pola r and d irectiv ity dat a 1/3 octav e aver aged. Kling & Fre itag res erves the ri ght to chan ge all specif ication s with out no tice. W e are not lia ble fo r misp rints.
20 100 1000 10000 20000
-30
0
Frequency(Hz)
dB
3,16
31,6
316
Impedance (Ohm)
100
-20
-10
10
10
Normal HiBoost
20 100 1000 10000 20000
-30
-20
-10
0
10
Attenuation (dB)
Frequency (Hz)
0° 10° 20° 30° 40°
-10
0
10
Attenuation (dB)
100 1000 10000 20000
0° 10° 20° 30° 40°
Frequency (Hz)
20
-30
-20
100 1000 10000 20000
0° 10° 20° 30° 40°
Frequency (Hz)
20
-30
-20
-10
0
10
Attenuation (dB)
20
20 100 1000 10000 20000
1
10
100
Directivity Factor (Q)
Directivity Index (DI), dB
Frequency (Hz)
0
10
20
-6dB Beamwidth (degr
ees)
100 1000 10000 20000
Frequency (Hz)
0
60
120
180
240
300
360
Horizontal Vertical
3.2.4 T9 Dimensions
15°
600 mm
588 mm
307 mm
900 mm
421 mm
750 mm
639 mm
Front View
Top View Bottom View
Sliders
Plastic
MAN Flying Point CF4T
Side View
Rear View
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 13 of 13
4. The Subwoofers
4.1 Short-Circuit Fuses in the K&F Subwoofer Systems
4.1.1 Risks of using High Performance Power Amplifiers
In recent years, power amplifiers have achieved increasingly higher levels of perfor­mance. Some of them can be operated with low-impedance loads. There are, therefore, strong power amplifiers that can reliably work with impedances below 1 . This devel­opment has led to an increased safety risk during defective operations.
When there is a defect, such as a short circuit in the speaker chassis or on the crossover, it is possible that the power amplifier --- despite existing protective switches --- will not shut off. Long cable lengths and contact resistance on the plug connections may already have an electrical resistance of 1 . As a result, the power amplifier cannot ‘‘recognise’’ the operations as being defective and, therefore, delivers unacceptable high currents. In the worst-case scenario, this may lead to fire damage (hot and charred wiring / con­nectors as a result of overloaded wires and connectors, etc.).
The current safety regula­tions are lagging behind this development and are thus not up-to-date with this modern technology.
Normally, the K&F System Controller prevents the speaker from being overloaded. The re­sults of such a defect cannot be avoided by the controller.
In order to give consideration to this development, Kling & Freitag now equips its sub­woofer systems with short circuit fuses at the signal input. These fuses do not offer protection for the speaker, but do reduce the risk of consequential damage in the case of a short circuit.
For systems, which are not serially equipped with a short circuit fuse, Kling & Freitag offers simple add-on kits so that you can adapt your existing subwoofer systems to the current power amplifier development.
4.1.2 Identifying the Models with Short-Circuit Fuses
The subwoofer systems, which are serially equipped with short-circuit fuses can be iden­tified as follows; both mentioned stipulations must be fulfilled:
4.1.3 Add-On Kits for Subwoofers without Short-Circuit Fuses
All subwoofer systems, which are not serially equipped with short circuit fuses, can be, if required, easily and inexpensively upgraded even by yourself.
An instruction manual for this upgrade is delivered with the add-on kit.
POWER: 700W
WT:
51,5kg
XO-ONOFF
SER.-NO.:
25080000070
IMP: 6
Ω8Ω
Zmin:
4
6
-
1
-
2
-
1+
2+
+
IN
all pins parallel to out
The first two
digits must be at
least 25.
The next two digits must be at least 08.
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 14 of 14
4.1.4 Specification of the Fuses
The fuses in all models have the following identical specifications:
Bussmann S 506
Bussmann S 506Bussmann S 506
Bussmann S 506----8A slow
8A slow8A slow
8A slow
When necessary, these fuses may only be replaced with the aforementioned original fuse.
4.1.5 Replacement and Positions of the Short-Circuit Fuses
When the fuse is blown, then the chassis is most likely already ruined, as the fuse just prevents consequential damage resulting from a short circuit of the chassis. A disassembly of the chassis is, therefore, unavoidable.
The fuse holder of the subwoofers is mounted on the signal wiring behind the input connector. The ACCESS subwoofers have 2 fuses; one for each of the parallel operating chassis.
When replacing the fuse, the lid of the terminal with the signal connectors must be screwed off to reach the fuse holder.
Warning
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 15 of 15
4.2 B5 Subwoofer System, Specifications
4.2.1 B5 Applications
The ACCESS B5 is a high-performance subwoofer system of the ACCESS Series. It is fully compatible with all existing Kling & Freitag speaker products and shows off all its qualities here too. Because of its high efficiency and technical perfection, the B5 is used in the high quality service segment, at discotheques and live sound coverage as well as venues with fixed installations such as theatres and multimedia facilities. When used in arrays with the optimally matched top speakers T5 and T9, the possibilities of use ex­pand to include large events and mega open airs. The T9 meets all demands at the highest level --- from hard rock to classic.
4.2.2 B5 Technical Specifications
Design 3 chamber band pass, 6th order Frequency response -10 dB 34 Hz - 400 Hz Frequency response ± 3 dB 45 Hz - 190 Hz Crossover frequencies max. 180 Hz, 130 Hz with controller C5/9 Nominal power handling 1200 W Sensitivity 1 W/1 m 101 dB (45 Hz - 200 Hz) Max SPL 136 dB (SPL peak/1 m) Components 18" long excursion transducers (2) Impedance
1 x 4 With option 'EP-5 instead of Speakon': 2 x 8
Connectors Sp.1: 2- / 3+-, Sp.2: 1- / 4+ Enclosure Trapezoid with 2 cluster angles 4°/15° 15 mm birch plywood with highly resistant black structured paint 4 ergonomic butterfly handles
4 100 mm transport castors mounted on the rear,
ball proof front grille with exchangeable black acoustic foam
Rigging 2 MAN CF4T flying points, 2 MAN HWKB strap attachments for securing straps Dimensions 600 x 900 x 750 mm without castors (W x H x D) Weight incl. castors 82 kg Options Transport cover with butterfly catches,
special finish in RAL colours, All Weather / Outdoor version
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 16 of 16
4.2.3 B5 Measuring Charts
Fr
equenzgang
on axis
Fr
equenzgang
on axis
mit Contr
oller
Alle Messungen unter Freifeldbedingungen. Frequenzgangdiagramme 1/6 Okt. geglättet. Technische Änderungen, dieder Verbesserungder Produkte dienen, behalten wir uns vor. Irrtümer vorbehalten.Subject to changewithout notice.
20
Frequency (Hz)
SPL (dB)
3,16
31,6
316
Impedance (Ohm)
100
10
70
80
90
100
110
100 1000
20
Frequency (Hz)
dB
100 1000
-30
-20
-10
0
10
4.2.4 B5 Dimensions
Front View
Top View
15 °
600 mm
Bottom View
Plastic Sliders
588 mm
MAN Rigging Point CF4T
307 mm
Side View
900 mm
421 mm
750 mm
639 mm
Rear View
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 17 of 17
4.3 B10 Subwoofer System
4.3.1 B10 Applications
The B10 is a universally usable high-performance subwoofer system for the reproduc­tion of low to very low frequencies. The B10 has been created to be used as the optimal addition to the ACCESS Series. It is fully compatible with all existing Kling & Freitag speaker products and shows off all its qualities here too. Because of its high efficiency and technical perfection, the B10 is used in the high quality service segment, at disco­theques and live sound coverage as well as venues with fixed installations such as thea­tres and multimedia facilities. The B10 allows for direct operation with ACCESS top speakers T5 and T9 as well as a phase-correct parallel operation with the bass system ACCESS B5. The B10 meets all demands at the highest level --- from techno to classic. The B10 can be operated with the K&F controllers C5/9, C10 and C2.
4.3.2 B10 Technical Specifications
Design 3 chamber band-pass horn enclosure Frequency response -10 dB 31 Hz - 320 Hz (without controller) Frequency response ± 3 dB 38 Hz - 260 Hz (without controller) Crossover frequencies max. 180 Hz, 130 Hz with controller C5/9 Nominal power handling 1) 1400 W Programme power handling 2) 2800 W Recommended amplification
2 - 3 kW @ 4
SPL 1 W/1 m 103 dB (40 Hz - 180 Hz) Max. SPL 140 dB (SPL peak/1 m) Components 18" long excursion transducers (2) Impedance
2 x 8 With option 'EP-5 instead of Speakon': 1 x 4
Connectors EP-5 male / female, Sp.1: 2- / 3 +, Sp.2: 1- / 4 + Enclosure 15 mm birch plywood with highly resistant black structured paint
8 ergonomic butterfly handles
4 100 mm transport castors mounted on the rear,
ball proof front grille with exchangeable black acoustic foam Dimensions 600 x 1350 x 880 mm w/o castors (W x H x D) Weight incl. castors 120 kg Options Transport cover with butterfly catches, special finish in RAL colours
1) Long term RMS power capability measured with pink noise signal, reduced bandwidth
40 Hz - 400 Hz, Testing period: 2 hours
2) Long term RMS power capability measured with 50% duty cycle,
reduced bandwidth 40 Hz - 400 Hz, Testing period: 2 hours
Operating Instructions ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2016 Version 6.2, 06.12.2016 Page 18 of 18
4.3.3 B10 Measuring Charts
Fr
equenzgang
on axis
Alle Messungen unter Freifeldbedingungen. Frequenzgangdiagramme 1/6 Okt. geglättet. Technische Änderungen, die der Verbesserung d er Produkte dienen, behalten wir uns vor. Irrtümervorbehalten. Subject to change without notice.
20
Frequency(Hz)
SPL(dB)
3,16
31,6
316
Impedance (Ohm)
100
10
70
80
90
100
110
100 1000
4.3.4 B10 Dimensions
600mm
Draufsicht Unter
sicht
Plastic Sliders
Rear View
880mm
1350mm
600mm
Front View
Side View
Stacking Moulds