Klimawent WPA-3-P-1-N, WPA-5-P-1-N, WPA-5-P-3-N, WPA-6-P-3-N, WPA-6-P-1-N Use And Maintenance Manual

...
1
27.09.2016 Portable radial fans WPA-P-N
Portable radial fans
WPA-P-N
2
Portable radial fans WPA-P-N 27.09.2016
Contents:
1. Introductory Remarks ......................................................................... 3
2. Application ......................................................................................... 4
3. Reservations of Producer .................................................................... 4
4. Technical Data .................................................................................... 5
5. Structure and Function....................................................................... 8
6. Assembly and Start-up ........................................................................ 8
7. Operational Use .................................................................................. 10
8. Trouble Shooting Guide ...................................................................... 11
9. Maintenance ....................................................................................... 11
10. Occupational Health and Safety .......................................................... 12
11. Transport and Storage ........................................................................ 12
12. Terms of warranty .............................................................................. 12
3
27.09.2016 Portable radial fans WPA-P-N
1. Introductory Remarks
The purpose of the present User’s Manual is to supply the Purchaser and the future User with directions within the range of application, installation, start-up and the operational use of the WPA-P-N portable radial fans.
Therefore, installing, start up and operational use are exclusively admissible after
getting acquainted with the contents of the User’s Manual. With regard to continuity of work carried on improvement of our products, we reserve for ourselves the revision possibility of the draft and technological changes improving their functional features and safety. In case when improper function and faults are by noise or
visually spotted, and they cannot be fixed on one’s own, contact the manufacturer or
representative. The construction of the WPA-P-N portable radial fans meets the requirements of the current
state of technology as well as the safety and health assurances included in:
2006/42/EC Machinery Directive of the European Parliament and of the Council of 17 May,
2006 on machinery – amending the 95/16/EC (recast) /Journal of Laws EC L157 of 09.06.2006, page 24/
2014/35/EC Directive of the European Parliament and of the Council of 26 February, 2014
on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits.
/Journal of Laws EC L96 of 29.03.2014/
The appliance meets the requirements included in:
2009/125/EC (ErP) Directive of the European Parliament and of the Council
of October 21th, 2009 establishing a framework for the setting of ecodesign requirements for energy-related products / Journal of Laws L 285 of 31.10.2009 /
327/2011 (EU) Guideline of March 30th, 2011 on implementing the 2009/125/EC Directive
of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW
/Journal of Laws L No. 90 of 06.04.2011/
The device has been constructed and produced on the basis of following harmonized standards:
PN-EN ISO 12100:2012
“Safety of machinery. Basic concepts, general principles for
design. Risk assessment and risk reduction”.
PN-EN 60204-1:2010
“Safety of machinery. – Electrical equipment of machines.
Part 1: General requirements”.
PN-EN 60034-1:2011
“Rotating electrical machines Part 1: Rating data
and parameters”.
PN-EN ISO 5802:2008
“Industrial Fans – Performance testing in situ of installing”.
PN-EN ISO 13857:2010
“Safety of machinery. Safe distances to prevent hazard
zones being reached by upper and lower limbs”.
4
Portable radial fans WPA-P-N 27.09.2016
2. Application
WPA-P-N portable radial fans have been designed for air-supply ventilation or extraction
ventilation of rooms and workplaces. They can be applied for general ventilation and for local exhausts. Additionally, WPA-P-N fans can be used or drying the humid rooms by forcing the multiple air exchanges. Do not use the fan for conveying the aggressive gases or substances creating explosive atmospheres with the air. In general, the fan is designed for transporting the air, of dustiness not exceeding 0,3 g/m³, without viscous impurities, aggressive contamination or compounds creating hazard of explosion.
3. Reservations of Producer
A.
Manufacturer is not liable for any consequences following from the operational use that is in contradiction to the purpose of application.
B.
Do not install any additional elements not belonging to the normal device structure or accessory set.
C.
Any structural changes or device modifications on one’s own are not permitted.
D.
Protect the appliance’s housing from mechanical damage.
E.
The fan cannot be used for conveying the air contaminated with a mixture of flammable substances in form of gas, vapour, mist and dust that in connection with the air create explosive atmosphere.
F.
Do not use the fan for conveying the air containing viscous impurities that could accumulate (build up) on the device surface, especially on the impeller.
G.
Neither use the fan for forwarding the air with aggressive pollutants which will destructively effect the device structure.
H.
During the use, the maximum impeller rotations should not exceed nominal rotations.
I.
Producer is not responsible for wounds, injuries, body laceration experienced by User or personnel during the improper operational use.
5
27.09.2016 Portable radial fans WPA-P-N
4. Technical Data
Table No.1 – Technical data for the subsequent types of fans
Type of the fan
Synchronous
rotations
Supply
voltage
Motor
rate
Ingress
pro-
tection
Acoustic
pressure level
[dB(A)]
from distance
Maximum
volume
flow
Maximum
vacuum
Weight
[r.p.m.]
[V]
[kW]
IP
1m
5m
[m3/h]
[Pa]
[kg]
WPA-3-P-1-N
3000
230
0,37
54
69
55
1160
940
16
WPA-5-P-1-N
3000
230
0,55
WPA-5-P-3-N
3x400
WPA-6-P-1-N
3000
230
0,75
54
83
69
2500
1700
24
WPA-6-P-3-N
3x400
WPA-7-P-1-N
3000
230
1,1
54
86
72
3100
1800
26
WPA-7-P-3-N
3x400
WPA-8-P-3-N
3000
3x400
1,5
54
88
74
3900
2050
35
WPA-9-P-3-N
3000
3x400
2,2
54
91
77
4500
2400
44
WPA-10-P-3-N
3000
3x400
3,0
54
91
77
6200
2450
55
1.
Maximum temperature of the conveyed air is +60ºC, whereas maximum temperature within the work zone +40ºC.
2.
Maximum dustiness of the conveyed air should not exceed 0,3 g/m3.
Fig. No.1 – Fan of the WPA-P-N series – Structure, dimensions