1. Introductory Remarks ........................................................................ 3
2. Application ......................................................................................... 3
3. Reservations of Producer .................................................................... 3
4. Technical Data ................................................................................... 4
5. Structure and Function ...................................................................... 9
6. Assembly and Start-up ........................................................................ 9
7. Operational Use .................................................................................. 10
8. Troubleshooting Guide........................................................................ 11
9. Maintenance ....................................................................................... 11
10. Occupational Health and Safety .......................................................... 11
11. Transport and Storage ........................................................................ 12
12. Terms of warranty .............................................................................. 12
13. Sample of the Declaration of Conformity ............................................ 16
![](/html/64/6479/6479121835ab13481e43ff578a62746106d5b70bc5063dd6b3ba5fa34fc6e6c4/bg3.png)
3
10.01.2019 Standing Extraction Arm ERGO LUX-{M; K; L; D}-R
1. Introductory Remarks
The purpose of the present Use and Maintenance Manual is to supply the Purchaser and the
future User with directions within the range of application, installation, start-up and the operational use of the ERGO LUX-R Extraction Arm.
Therefore, installing, start up and operational use are exclusively admissible after getting acquainted with the contents of the Use and Maintenance Manual.
With regard to continuity of work carried on improvement of our products, we reserve for ourselves the revision possibility of the draft and technological changes improving their functional
features and safety.
The construction of the ERGO LUX-R Extraction Arm meets the requirements of the current
state of technology as well as the safety and health assurances included in:
2006/42/EC Machinery Directive of the European Parliament and of the Council of 17 May,
2006 on machinery – amending the 95/16/EC (recast) /Journal of Laws EC L157 of 09.06.2006, page 24/
The device has been constructed and produced on the basis of following harmonized
standards:
“Safety of machinery – Basic concepts, general principles
for design. Risk assessment and risk reduction”.
2. Application
ERGO LUX-R Extraction Arm has been developed for capturing the welding dust particles
and welding gas and also other fine dust particles, directly at the emission source, in order
to avoid the contamination expanding within the process room / hall and to protect the people
in the vicinity from inhaling the contamination.
The extraction arms are manufactured in hanging and standing version. They can work independently, in a single configuration with one extraction fan, or in a group of extraction arms,
connected to the main collecting ductwork (with a central fan).
3. Reservations of Producer
Producer is not responsible for failures arising during the use that is inconsistent to the
purpose of application.
Installing any additional elements not belonging to the normal device structure (or accessory set) is not acceptable.
Any structural changes or modification of the unit carried out by User on one’s own are
not permitted.
Protect the flexible elements and the suction duct segment (pipe) from mechanical dama-
ge.
Prior to installing examine the load capacity of the of the wall or other building structure
in points where the device shall be mounted.
Unsure mounting could cause hazard to personnel / people in the vicinity, as well as damage of the device itself.
Do not use the device for conveying the air mixture with combustible substances,
in form of gas, vapour, mist or dust – that might create explosive atmosphere.
![](/html/64/6479/6479121835ab13481e43ff578a62746106d5b70bc5063dd6b3ba5fa34fc6e6c4/bg4.png)
4
Standing Extraction Arm ERGO LUX-{M; K; L; D}-R 10.01.2019
Do not apply the device for conveying the air containing viscous compounds that would deposit on the surface of the device elements.
Do not apply the device for conveying the air containing aggressive compounds that would
have destructive effect on the device elements.
Maximum admissible vacuum in the system cannot exceed 800 Pa.
In case of higher vacuum of the system, (where the ERGO LUX-R extraction arm is installed),
damage of the hoses would occur.
4. Technical Data
Fig. No.1 – Extraction Arms type ERGO LUX-R – Dimensions and Structure
Table No.1 – Extraction Arms type ERGO LUX-R – Dimension, weight
![](/html/64/6479/6479121835ab13481e43ff578a62746106d5b70bc5063dd6b3ba5fa34fc6e6c4/bg5.png)
5
10.01.2019 Standing Extraction Arm ERGO LUX-{M; K; L; D}-R
Extraction arms type ERGO LUX-LL-R and ERGO LUX-DL-R are equipped with hoods with
halogen spotlights. For information about the connection of the lighting see the Connection
Diagram enclosed to the present Use and Maintenance Manual (see Fig. No.4).
Table No.2 – Hoods for the ERGO LUX-R extraction arms
ERGO LUX-M/1,5-R
ERGO LUX-M/2-R
– replace able
inlet wire-
mesh
ERGO LUX-K/2-R
ERGO LUX-K/3-R
ERGO LUX-L/2-R
ERGO LUX-L/3-R
ERGO LUX-L/4-R
ERGO LUX-D/2-R
ERGO LUX-D/3-R
ERGO LUX-D/4-R
ERGO LUX-LL/2-R
ERGO LUX-LL/3-R
ERGO LUX-LL/4-R
– replace able
inlet wire mesh
– halogen
spotlight
12V
– switch
ERGO LUX-DL/2-R
ERGO LUX-DL/3-R
ERGO LUX-DL/4-R
Table No.3 – Inlet wire-mesh for the hoods
![](/html/64/6479/6479121835ab13481e43ff578a62746106d5b70bc5063dd6b3ba5fa34fc6e6c4/bg6.png)
6
Standing Extraction Arm ERGO LUX-{M; K; L; D}-R 10.01.2019
Table No.4 – Wall bracket – additional element of the device
Cooperating
extraction arms
ERGO LUX-M-R
ERGO LUX-K-R
Fig. No.2 – Work ranges of the extraction arms
Table No.5 – Dimensions of the work ranges of the extraction arms
ERGO LUX-L(L)/2-R
ERGO LUX-D(L)/2-R