KUIR - KFUF / KSIE - KSIR
Floor-Ceiling Unit Technical Specifications
Klimaire Indoor Unit Model Number
Klimaire Outdoor Unit Model Number
Power supply
Capacity
Cooling EER
V-ph-Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Btu/h
Btu/W
KUIR18-H2 KUIR24-H2 KFUF036-H2G1 KFUF048-H2G1
KSIE018-H220-O KSIE024-H220-O KSIR036-H218 KSIR048-H218
18000 24000 36000 48000
12,5 12,5 8,0 9,3
SEER 20 20 16 17,8
Capacity
Heating @ 47º F COP
Btu/h
W/W
18000 24000 38000 50000
3,2 3,8 2,8 3,2
HSPF 10,5 11 10,0 11,0
Heating @ 17º F Rated capacity
Minimum circuit ampacity
Max. fuse size
Indoor fan motor Input
RLA
Speed(Hi/Med/Lo)
SYSTEM
Indoor air flow (Hi/Med/Lo)
Indoor noise level (Hi/Med/Lo)
Indoor unit Dimension (WxDxH)
Packing (WxDxH)
Net/Gross weight
Design pressure
Drainage water pipe diameter
Refrigerant piping Liquid side/Gas side
Btu/h
A
A
W
A
rpm
cfm
dB(A)
in
in
lb
psig
in
in
12000 15000 25400 35000
15 18 30 35
20 25 50 50
100 100 130 96
1,5 2 1,5 1,8
950/850/750 1350/1260/1120 1300/1150/800 1320/1200/1120
578/521/465 759/708/598 1037/917/638 1350/1120/1000
47/44/39 53/48/42 54/49/43 57/54/52
42.05x26.57x9.25 42.05x26.57x9.25 50.59x26.57x9.25 64.96x26.57x9.25
45.08x29.72x12.32 45.08x29.72x12.32 53.54x29.72x12.32 67.91x29.72x12.32
55.12/65.48 58.42/69.23 69/81.57 83.78/97
550/340 550/340 550/340 550/340
1 1 1 1
1/4"/1/2" 3/8"/5/8" 3/8"/5/8" 3/8"/5/8"
Controller Remote control Remote control Remote control Remote control
Room temperature
Cooling
Heating
Operation temperature 62~86 62~86 62~86 62~86
ºF
ºF
ºF
62~90
32~86
62~90
32~86
62~90
32~86
62~90
32~86
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
OUTDOOR UNIT PRODUCT CODE
W
–
O
Efficiency
SEER
Power Supply
1 : 115 / 1 / 60
2 : 208-230 / 1 / 60
XX
Unit Type
O: Outdoor
D
Production
H
Brand
K: Klimaire
Unit Type
I : Inverter
K
Model
S: Universal Wall Mout
T: Ceiling Cassette
D: Slim Duct
U: Floor-ceiling
Product Series
Series
F
Brand
K: Klimaire
Model
S: System
K
Unit Type
I : Inverter
Product Series
E: Series
R: Series
S
R
I
W
036–H
Nominal Capacity
18: 18,000 Btu/h
24: 24,000 Btu/h
36: 36,000 Btu/h
48: 48,000 Btu/h
H
D
2 18
Operational Information
H: Heat Pump
C: Cooling Only
INDOOR UNIT PRODUCT CODE
U
F
W
Nominal Caoacity
036: 36,000 Btu/h
048: 48,000 Btu/h
060: 60,000 Btu/h
036
–
D
H
H
2
XX
Power Supply
2 : 208-230 / 1 / 60
Operational Information
H: Heat Pump
C: Cooling Only
Production