DC Inverter is a type of power conversion circuit that electronically regulates the voltage, current and frequency of a compressor or a motor. DC INVERTER-drivenair conditioners and heat pumps bear special double cam, twin rotary variablespeedcompressor.Likeacruisecontrolofavehicle.Inverter technology varies the compressor speed based on cooling and heating needs in the space. Variable speed enables to precisely match system capacity to actual load. They can slow down or speed up based on demand load. By varying the speed of the compressor systems are able to better match load in heating and cooling. In multi zone inverter systems the indoor units constantly change capacity and electronically communicate with the Klimaireoutdoor unit to increase or decrease capacity for optimum comfort and save energy. Therefore systems operate more efficiently at light load, while still being capable of increasing the speed to deliver full capacity when needed.
We have been in Ductless mini-split business since 1989 and at Klimaire maintain the highest quality and reliability with ISO
9001 and ISO 14001 standards in our manufacturing facilities. Our products have proven their endurance and resiliency over
time operating in 70 different countries since then. All products are ETL certified and AHRI registered.
Klimaire products exceed industry standards for energy efficiency and employs innovative technology to achieve the highest
customer satisfaction. Since our goal is to achieve maximum customer satisfaction, we continuously seek to achieve in the
design phase of our future units higher performance levels.
Ductless mini-split systems are one of the fastest growing products in the US and popularity is rapidly increasing. They allow air
conditioning and heating systems to be added quickly, economically and conveniently, often for some applications where
installing comfort systems didn't seem possible or practical.
Flexibility is the main role of their popularity.
Klimaire ductless systems are simple, reliable, and easy to install as well as affordable. Klimaire slim single zone and multi zone
ductless systems offer built-in solution with duct free technology benefits. These systems are integrated with innovative inverter
technology providing individual comfort and control. We are committed to bring you real comfort with our series to our valuable
customers where you Like it, when you Like it and how you Like it.
Inverter Technology
DC Inverter is a type of power conversion circuit that electronically regulates the
voltage, current and frequency of a compressor or a motor. DC INVERTER-driven air conditioners and heat pumps bear special double cam, twin rotary
variable speed compressor. Like a cruise control of a vehicle. Inverter
technology varies the compressor speed based on cooling and heating needs in
the space. Variable speed enables to precisely match system capacity to actual
load. They can slow down or speed up based on demand load. By varying the
speed of the compressor systems are able to better match load in heating and
cooling. In multi zone inverter systems the indoor units constantly change
capacity and electronically communicate with the Klimaire outdoor unit to
increase or decrease capacity for optimum comfort and save energy. Therefore
systems operate more efficiently at light load, while still being capable of
increasing the speed to deliver full capacity when needed.
Room Temp.
Set
Temp.
Since humidity is a major factor for comfort,
in the summer, Klimaire DC INVERTER – dr i ven va r iabl e s pee d c o mpr e ssor s
reduces capacity to match lighter loads
increasing the run time to remove moisture
and reduce relative humidity resulting in
im p rov e d com f ort . I n the w i nte r, b y
increasing the speed of the compressor
Klimaire air conditioner and heat pump
systems are able to maintain capacity and
deliver hotter supply air even at low outdoor
ambient conditions.
Fixed Speed AC
DC Inverter AC
Too Hot
Comfortable
Too Cold
T2
T1
Time
2
Page 3
Flexible Match Systems
Commercial Applications
Light commercial units are the perfect solution for large
open spaces. These units are more than just an air
conditioner, but a decorative element featuring a design
suitable for office interior décor that complements the
living environment.
Experience the True Individual Comfort - The Smart Choice
Ductless air conditioning systems are
perfect solution to variety of installation
challenges, allowing installers the ability to
place ductless air conditioning units in
locations that were previously impractical
or impossible. They are ideal when
additional ductwork is necessary but not
cost effectively. Basically Ductless minisplit units eliminate the use of ductwork.
In addition to eliminating the need for
ducting, one of the other great advantages
of ductless multi-split systems is true zone
control. Each indoor fan coil unit is
dedicated to the room being conditioned
allowing a temperature and humidity level
to be kept different from the rest of the
house or the building. It has never been
easier or more cost effective to cool and
heat multiple rooms from a single outdoor
unit. The most advantage of the multi
zone system is once all indoor units in
operation, cooling or heating, at the same
time the system will limit the indoor unit
capacity so that they will match with the
outdoor unit capacity. When a zone meets
the desired set temperature it requires less
capacity. The unused capacity is then
distributed to the remaining indoor units
under operation, increasing their capacity.
By rotating the capacity multi zone
systems are preferred to increase diversity
in heating and cooling loads for day and
night operation.
Up to 21 SEER and 24,000 Btu
Up to 21 SEER and 24,000 Btu
Up to 21 SEER and 24,000 Btu
Up to 21 SEER and 24,000 Btu
OUTDOOR UNIT
KSIR036-H218
OUTDOOR UNIT
KSIR048-H218
OUTDOOR UNIT
CEILING CASSETTE
Up to 18 SEER and 36,000 Btu
CEILING CASSETTE
Up to 18 SEER and 48,000 Btu
CEILING CASSETTE
DUCTED RECESSED
DUCTED RECESSED
DUCTED RECESSED
FLOOR/CEILING
FLOOR/CEILING
FLOOR/CEILING
KSIR030-H215
KSIR036-H215
OUTDOOR UNIT
Up to 16 SEER and 30,000 Btu
Up to 16 SEER and 36,000 Btu
WALL MOUNT
4
Page 5
Noise Level
dB(A) Level
140
105
70
Jet Engine
at 100ʼ
Power
Tools
Normal
Conversation
from 3 - 5ʼ
Flexible and Quiet
Like regular split air conditioning or heat pump systems, the
condensing unit is installed outdoors allowing a peaceful and
more comfortable interior environment.
Zone Application
For maximum comfort throughout the entire house multi zone Invertech
models are ideal to best match your room requirements when it is needed
to condition more than one space. It is not necessary to use several
separate systems. Klimaire 2, 3 4 or 5 zone systems can easily respond to
your heating and cooling needs. Each indoor unit is independently
controlled to meet your specific comfort preferences, and there are several
models available in ductless and ducted type designed to be placed just
about anywhere for any application for your home or your business.
35
Whisper
Quiet
Library
Klimaire
Unit
Klimaire multi zone inverter models can provide the highest diversity
design flexibility in your home for day and night operation. Klimaire offers
three different multi zone systems – dual zone, tri zone, and quad zone –
0
Weakest
Sound
Heard
with different appearance to fit your own decor.
OUTDOOR
UNIT
5
48,000 Btu
Outdoor Unit
Page 6
Compact & Slim Cassette
6
Page 7
KTIR
Ceiling Casette
Compact Design
22.4
10.4
22.4
Compact Cassees 9, 12 & 18,000 Btu
Slim Cassee 24, 36 & 48,000 Btu
The recessed ceiling cassee unit is ideal for installaon in spaces where duct-work is impraccal or
impossible and can share its cooling and heang capacity with an adjacent room by means of a flex duct
connecon and provide comfort to every corner of a room.
The off-white color of the decorave ceiling panel blends with any ceiling configuraon.
Compact cassees fit into standard 2’ x 2’ ceiling grid
Powerful turbo fan operaon
Fresh air intake design 2.5" Φ
Flexible installaon with built-in drain pump
6” supply duct connecon to an adjacent room
Self diagnosis for easy maintenance
Easy Installaon
Temperature
An-Cold-Air
22.4”
22.4”
Auto restart
Follow me funcon
*Dimensions of outer grille are 22.5” x 22.5” and may overlap adjacent les.
compensaon
switch (KTIR)
Sleep mode
5° low ambient
5ºF
heang/cooling
Slim Design
33
Auto swing
360°
louver with 360º
air distribuon
46º F Home away
46°
winter vacaon
33
8
Electronic board with reserved ports to connect and control
field supplied inline fan to increase fresh air intake
Klimaire Model NumberKTIR09-H2
Power supply
Capacity
Indoor fan motor RLA
Indoor air flow (Hi/Mid/Lo)
Indoor noise level (Hi/Mid/Lo)
Indoor unitDimension (WxDxH) (panel)
Design pressure
Drainage water pipe diameter
Refrigerant piping Liquid side/Gas side (Flare)
Control typeRemote controlRemote controlRemote controlRemote control
Room temperature
Operaon temperature
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
Cooling
Heang @ 47ºF
Power input
Speed (Hi) rpm600/520/460680/580/500730/630/570
Dimension (WxDxH) (body)
Packing (WxDxH) (body)
Packing (WxDxH) (panel)
Net/Gross weight (body)
Net/Gross weight (panel)
CoolingºF
HeangºF
V-ph-Hz
Btu/h90001200018000
Btu/h100001200018000
W
A
cfm
dB(A)
in
in
in
in
lb
lb
psig
in
in
ºF
208-230~1-60
45 45 45
0,9 1,0 1,5
374/301/257379/309/261
41/37/3343/39/36
22.44x22.44x10.2422.44x22.44x10.24
25.79x25.79x11.4225.79x25.79x11.42
25.47x25.47x1.9725.47x25.47x1.97
28.15x28.15x4.8428.15x28.15x4.84
31.97/38.1435.27/41
5.51/9.925.51/9.925.51/9.9211.02/17.64
540/300 PSIG540/300 PSIG550/340 PSIG550/340 PSIG
OD Φ1"OD Φ1"OD Φ1"ODΦ 1" 1/4
1/4" / 3/8"1/4" / 1/2"1/4" / 1/2"3/8" / 5/8"
62~9062~9062~9062~90
32~8632~8632~8632~86
62~8662~8662~8662~86
KTIR12-H2
208-230~1-60208-230~1-60208-230~1-60
KTIR18-H2
560483/415700/636/573
44/39/3651/47/43
22.44x22.44x10.2433.07x33.07x8.07
25.79x25.79x11.4235.43x35.43x8.54
25.47x25.47x1.9737.4x37.4x2.17
28.15x28.15x4.8440.75x40.75x3.54
35.49/41.2346.3/54.23
KTIR24-H2
24000
24400
58
2
600/520/450
Condensate water can be
pumped up to 30" higher
elevaon for easy drainage
KTIR036-H2G1
208-230~1-60
36000
25200
141
1,5
720/630/560
1095/958/809
55/52/49
33.1x33.1x9.7
35.4x35.4x10.1
37.4x37.4x2.2
40.8x40.8x3.5
58.2/66.14
11.02/17.64
550/340 PSIG
'1 - 9/32
3/8" / 5/8"
Remote control
62~90
32~86
62~86
KTIR048-H2G1
208-230~1-60
950/900/800/700
1177/1030/853
33.1x33.1x11.3
35.4x35.4x11.5
37.4x37.4x2.2
40.8x40.8x3.5
63.27/72.53
11.02/17.64
550/340 PSIG
Remote control
48000
35000
232
1,6
55/52/49
'1 - 9/32
3/8" / 5/8"
62~90
32~86
62~86
7
Page 8
Ceiling & Floor
8
Page 9
KUIR - KFUF
Floor-Ceiling Mounted
Floor - Ceiling Mounted 18, 24, 36 & 48,000 Btu
Floor-ceiling mounted fan coils can
be mounted low on the wall, floor
or hanging on the ceiling without
any modificaon.
Extremely quiet and rugged
construcon makes it ideal for areas
of heavy traffic and public areas.
Ceiling applicaonFloor applicaon
Flexible and Easy Installation
Slim stylish profile, off white color to blend in any deco
Versale mounng floor or ceiling applicaon
Mulple operaon modes
Washable, re-usable air filter
LCD wireless remote control
Fresh air intake port
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
KSIR high wall mounted indoor unit sleek design matches any type of décor. They mount
high on a wall, out of sight and do not require ductwork, increasing energy efficiency. This
Klimaire newly designed, jam-packed with high-tech features, sleek and aracve indoor
unit is whisper quiet, and comes with fully-funcon remote control along with many
comfort indoor air quality features for individual comfort. You can choose from heang,
cooling, fan or dehumidificaon modes, built-in emergency MANUAL switch buon for
convenience and wall bracket for easy installaon.
Standard Features
* Louver posion memory
* Decorave and elegant design
* Super quiet
* Emergency use funcon
4.75in
or more
5.9in or more
An-Cold-Air
(Heat Pump Only)
Auto restart
4.75in
or more
90.55in or more
Klimaire Indoor Unit Model NumberKSIR030-H215-IKSIR036-H215-I
Klimaire Outdoor Unit Model NumberKSIR030-H215-OKSIR036-H215-O
Power supplyV-ph-Hz208-230/1/60208-230/1/60
Capacity Btu/h3000036000
CoolingEER Btu/w10,58,5
SEER1816
Capacity Btu/h3000036000
HeatingCOPW/WCOPCOP
HSPF9,610
Minimum circuit ampacity (MCA)A2025
Max. fuse sizeA3035
Power input W5858
Indoor fan motorRLAA0,50,5
SYSTEM
Indoor air flow (Hi/Med/Lo)cfm795/618/471853/647/471
Refrigerant pipingLiquid side/ Gas side in3/8"/5/8"3/8"/5/8"
ControllerRemote ControlRemote Control
Operation temperature Outdoor (cooling/heating) -w/o low ambient coolingºF32~122/5~86
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
MODE Button
Press this button to modify the air conditioner
mode in a sequence of following:
AUTO
NOTE: Please do not select HEAT mode if the
machine you purchased is cooling only type.
Heat mode is not supported by the cooling
only appliance.
3
FAN Button
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
NOTE: You can not switch the fan speed in
AUTO or DRY mode.
COOL
DRY
HEAT
FAN
Universal Control
KSIR / KTIR / KUIR / KDIR
AUTO
FAN
1
ON/OFF
AUTO
SILENCE
FP
8
SILENCE/FP Button
Active/Disable SILENCE function. If pushing
more than 2 seconds, the “FP” function will
be activated, pushing more than 2 seconds
again to disable.
When the Silence function is activated, the
compressor will operate at low frequency
and the indoor unit will bring faint breeze,
which will reduce the noise to the lowest
level and creat a quiet and comfortable room
for you. Due to low frequency operation of
compressor, it may result in insufficient
cooling and heating capacity.
Activates/Disables freeze protection”FP”
or HOME-AWAY function. It can only be
activated during the heating operation.
7
8
(only when the setting mode is HEAT).
The unit will operate at high fan speed with the
temperature automatically set to 46 F. The
display window of indoor unit will display FP.
For the unit without display area, the Defrost
indicator light will be keeping on for 2 seconds
Keeps the room over freezing temperature.
4
SLEEP Button
Active/Disable sleep function. It can
maintain the most comfortable temperature
and save energy. This function is available
on COOL, HEAT or AUTO mode only .
For the detail, see “sleep operation” in
“USER´S MANUAL”.
NOTE: While the unit is running under SLEEP
mode, it would be cancelled if MODE, F
SPEED or ON/OFF button is pressed.
5
TURBO Button
Active/Disable Turbo function. Turbo function
enables the unit to reach the preset temperature at cooling or heating operation in the
shortest time (if the indoor unit does not
support this function, there is no
corresponding operation happened when
pressing this button.)
6
SELF CLEAN Button
Active/Disable Self Clean function.
Under SELF CLEAN mode, the air
conditioner will automatically clean and dry
the Evaporator and keep it as fresh for the
next operation.
7
UP Button ( )
Push this button to increase the indoor
temperature setting in 1F increments to 86ºF.
DOWN Button ( )
Push this button to decrease the indoor
temperature setting in 1F increments to 62ºF.
NOTE: Temperature contol is not available
in Fan mode.
NOTE: Press and hold UP and DOWN buttons
together for 3 seconds will alternate the temperature display between the ºC & ºF scale.
o
o
AN
2
3
4
MODE
TEMP
FAN
SLEEP
TIMER
ON
TIMER
OFF
SWING DIRECT
9
10
11
9
TIMER ON Button
Press this button to initiate the auto-on
time sequence. Each press will increase
the auto-timed setting in 30 minutes
increments. When the setting time displays
10.0, each press will increase the autotimed setting 60 minutes increments.
To cancel the auto-timed program, simply
adjust the auto-on time to 0.0.
12
SELF
TURBO
5
CLEAN
6
LED
FOLLOW
ME
13
14
10
TIMER OFF Button
Press this button to initiate the auto-off time
sequence. Each press will increase the auto
-timed setting in 30 minutes increments.
When the setting time displays 10.0, each
press will increase the auto-timed setting
60 minutes increments. To cancel the autotimed program, simply adjust the auto-off
time to 0.0
11
SWING Button
Used to stop or start horizontal louver auto
swing feature.
12
DIRECT Button
Used to change the louver movement and set
the desired up/down air flow direction.
The louver changes 6 in angle for each press.
13
FOLLOW ME Button
Push this button to initiate the Follow Me
feature, the remote display is actual
temperature at its location. The remote
control will send this signal to the air
conditioner every 3 minutes interval until
press the Follow Me button again. The air
conditioner will cancel the Follow Me feature
automatically if it does not receive the signal
during any 7 minutes interval.
14
LED Button
Disable/Active indoor screen Display. When
pushing the button, the indoor screen display
is cleared, press it again to light the display.
The slim duct hide-away low profile fan coil unit ca be mounted above
a dropped ceiling or in an ac space, no floor space or cabinet enclosure
is required. They use minimal duct-work which makes it very
energy efficient, back air inlet is standard, and boom is oponal.
Concealed and out of sight
As efficient as a min-split with the appearance of central air
Shorter duct-work lower duct losses equal higher efficiency
Return air interchangeable back or boom flange plate
Fresh air intake duct connecon
Advanced high tech built-in control board
Standard Features
Insulated cabinet ,quite operaon with a touch of compact design
Stac pressure fan switch for various duct designs
Convenient standard dual remote control, wired and wireless.
Slim Duct
Suitable where ceiling cavity is small.
Exterior drain pump could be required where
there is not enough slope for drain.
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
13
Page 14
KDIR Wired Remote ControlKDIR Wired Remote ControlKDIR Wired Remote Control
1
Operation mode indication:
When press " MODE " button, the follow-
ing mode can be selected in circle. Auto
→Cool →Dry→Heat→Fan only→Auto.
For cooling only model,heat mode is
skipped.
2
Timer :
When adjust setting on time or only on
time is set, the "ON" is lighted.
When adjust setting off time or only off
time is set , the "OFF" is lighted. If on
and off timer are both set, the"ON" and
"OFF"are both lighted.
Operation mode indication
Timer ON/OFF
MODE BUTTON
TIMER ON BUTTON
TIMER OFF BUTTON
FOLLOW ME BUTTON
ELECTRICAL
HEATER BUTTON
3
Follow me function:
There is a temperature sensor inside the
wire controller, after setting temperature,
it will compare the two temperatures,
and the space of wire controller will be
the same as setting temperature. It is
available under cooling, heating, auto
mode.
4
: ON/OFF indication :
When it is on, the icon display,
otherwise it is extinguished.
5
; Fan speed indication :
There are four fan modes : low, middle,
high, auto. For some models, no middle
fan then the middle fan is seen as high
speed.
6
< Lock:
When the " LOCK " button is pressed,
the icon appear and other buttons is
unable, press again, the icon disappear.
7
= Temperature display zone:
Generally it displays setting tempera-
ture, it can be adjusted by press
temperature button ▲ and ▼. But in fan
mode, no display here.
ON / OFF BUTTON
7
1
3
Follow me function
4
2
1
2
1
2
3
4
5
ON/OFF indication
5
Fan speed indication
Lock
6
Temperature display zone
7
ADJUST BUTTON
8
9
ADJUST BUTTON
SWING BUTTON
10
ECONOMY BUTTON
11
RESET BUTTON
Mode botton:
1
When press this botton,the operation
mode change as the following
sequence:
:
→AUTO → COOL→DRY→HEAT→FAN
Remark: For the cooling only model, the
heating mode is skipped.
Timer on button :
2
Press this button, timer on function is
active. Then every press, the time
increase 0.5h, after 10h, 1h
increasement after each press. If cancel
this Function, just set it to "0.0" .
3
Timer off button:
Press this button, timer off function is
active.Then every press, the time
increase 0.5h, after 10h, 1 h
increasement after each press. If
6
All the pictures in this manual are for explanation purpose only. There may be
slightly different from the wire controller you purchased(depend on model). The
actual shape shall prevail.
cancel this function, just set it to "0.0" .
4
Follow me button :
When under cool, heat and auto mode,
press this button, follow me function is
active. Pressing the ON/OFF button or
MODE button will not cancel the Follow
me feature. This function is disable
when the unit is off or under DRY or FAN
mode. Pressing the FOLLOW ME button
again will cancel the follow me feature.
;Electrical heater button :
5
If press this button in heat mode, electri-
cal heater function become ineffective.
< Reset button(hidden):
6
Use a 1mm stick to press in the little hole,
then the current setting is canceled. The
wire controller enter into original state.
FAN SPEED BUTTON
12
13
= ON/OFF button:
7
When in off state, press this button, the
indicator is on, the wire controller enter
into on state, and send setting information
to in door Pcb. When in on state,press this
button, the indicator is off, and send
instruction. If timer on or timer off has
been set, it concel this setting then send
instruction to stop the machine.
Adjust button ▲:
>
8
Set indoor temperature up. If press and
hold on, it will increase at 1°C(1°F) per
0.5 second.
Adjust button ▼ :
9
Set indoor temperature down. if press and
hold on, it will decrease at 1°C(1°F) per
0.5 second.
LOCK BUTTON
14
Page 15
NOTE: Press and hold UP and DOWN
buttons together will alternate the
temperature display between the °C & °F
scale.
Swing button:
@
10
Used to set the airflow direction. Hold
down this button for 2 seconds to
activate auto swing feature.
Economy operation button :
11
11
press this button, the indoor unit
operates in economy mode, press again,
exit this mode (it may be ineffective for
some models)
Fan speed button:
12
12
press this button consecutively, the fan
speed will circle as follow:
13
Lock button(hidden):
When you push the LOCK button, all
current settings are locked in and the
wire controller does not accept any
operation except that of the LOCK
button. Use the lock mode when you
want to prevent setting from being
changed accidentally or play fully. Push
the LOCK button again when you want
to cancel the LOCK mode.
USING METHOD
AUTOMATIC OPERATION
Connect to power,indoor operation lamp
flash.
1. Press "MODE" button, select " AUTO "
;
temperature you want, generally it is
among 17°C(62°F)~30°C(86°F);
3. Press " ON/OFF" button, operation
lamp is on, the air-conditioner work in
auto mode, indoor fan is auto, and can
not be changed. Auto is displayed on
LCD. Press ON/OFF button again to stop.
4. Economy operation is valid in auto
mode.
5. In event of power interruption such as
a blackout, the air conditioner stops once.
But it restarts automatically and performs
previous operation when the power
supply is resumed.
COOL/HEAT/FAN MODE OPERATION
1. Press "MODE" button, select "COOL"
, "HEAT" or "FAN ONLY" mode.
2. Press temperature adjust button to
select setting temp.
3. Press "FAN SPEED" button to select
high/mid/low/auto.
4. Press "ON/OFF" button, indoor unit
operation lamp on, it works in selected
mode. Press "ON/OFF" button again, it
stops to work.
Remark: When in fan mode, no
temperature can be set.
DRY OPERATION
1. Press " MODE " button, select " DRY "
mode.
2. Press temperature adjust button to
select setting temp.
3. Press " ON/OFF " button, indoor unit
operation lamp on, it works in dry mode.
Press ON/OFF button again, it stops to
work.
4. In dry mode, economy operation and
fan speed are ineffective.
8
TIMER SETTING
Timer on only:
1. Press " TIME ON " button, it display
"SET" on LCD, and display " H " and "ON"
, it is waiting for timer on setting.
2. Press " timer " on button repeatedly to
adjust time setting.
3. If press this button and hold on, the
time will increase at 0.5h, after 10h, it
increase at 1h.
4. After setting 0.5 second, the wire
controller send timer on information, it is
finished.
Timer off only:
1. Press "TIME OFF " button, it display
"SET" on LCD, and display " H " and ON,
it is waiting for timer on setting.
2. Press "TIME OFF" button repeatedly to
adjust time setting.
3. If press this button and hold on , the
time will increase at 0.5h, after 10h, it
increase at 1h.
4. After setting 0.5 second, the wire
controller send timer off information, it is
finished.
TIMER ON AND TIMER OFF BOTH
1. Set timer on time as the
corresponding step1 and 2.
2. Set timer off time as the
corresponding step1 and 2.
3. Timer off time must be longer than
timer on time.
4. 0.5 second after setting, the wire
controller send information.the setting is
finished.
CHANGE TIMER
If there is a need of changing timer
time, press corresponding button to
revise it. If concel timer, change timer
time to 0.0.
TIMER
FOLLOW
ME
ON
TIMER
AUXIL
HEATER
MODE
LOCK
RESET
OFF
FANSPEED
SWING
ECO
TEMP
15
Page 16
KDIR / KDIM Remote Control
6
1
7
7
2
3
4
5
6
1
2
3
4
5
ON/OFF Button
Operation starts when this button is pressed and stops
when this button is pressed again.
MODE Button
Each time the button is pressed, the operation mode is
selected in a sequence of following:
AUTO COOL DRY HEAT FAN
NOTE: Please do not select HEAT mode if the machine you
purchased is cooling only type. Heat mode is not supported
by 0 the cooling only appliance.
FAN Button
Used to select the fan speed in four steps: r
AUTO LOW MED HIGH
SLEEP Button
Active/Disable sleep function. It can maintain the most
comfortable temperature and save energy. This function is
available on COOL, HEAT or AUTO mode only.
NOTE: While the unit is running under SLEEP mode, it
would be cancelled if MODE, FAN SPEED or ON/OFF
button is pressed.
TURBO Button
Active/Disable Turbo function. Turbo function enables the
unit to reach the preset temperature at cooling or heating
operation in the shortest time(if the indoor unit does not
support this function, there is no corresponding operation
happened when pressing this button.)
14
8
9
10
11
12
13
8
9
10
11
12
13
14
SELF CLEAN Button
Active/Disable Self Clean function. Under self clean
mode, the air conditioner will automatically clean and
dry the evaporator and keep it as fresh for the next
operation.
UP Button ( )
Push this button to increase the indoor temperature
setting in 1°F increments to 86°F.
DOWN Button ( )
Push this button to decrease the indoor temperature
setting in 1°F increments to 62°F.
NOTE: Press and hold and buttons together for 3
seconds will alternate the temperature display between
the °C & °F scale.
SHORTCUT Button
Used to restore the current settings or resume
previous settings. On the first time connecting to the
power, if push the SHORTCUT button, the unit will
operate on AUTO mode, 80°F, and fan, speed is Auto.
• Push this button when remote controller is on, the
system will automatically revert back to the previous
settings including operating mode, setting temperature,
fan speed level and sleep feature (if activated). And
transmit the signals .to the unit.
• If push this button when remote controller is off, the
system will only resume the previous settings and will
not transmit the signals to the unit. And the sleep
feature is disable.
• If pushing more than 2 seconds, the system will
automatically restore the current operation settings
including operating mode, setting temperature, fan
speed level and sleep feature(if activated ).
TIMER ON
Button Press this button to initiate the auto-on time
sequence. Each press will increase the auto-timed
setting in 30 minutes increments. When the setting
time displays 10, each press will increase the autotimed setting 60 minutes increments. To cancel the
auto-timed program, simply adjust the auto-on time to
0.0.
TIMER OFF Button
Press this button to initiate the auto-off time sequence.
Each press will increase the auto-timed setting in 30
minutes increments. When the setting time displays
10, each press will increase the auto-timed setting 60
minutes increments. To cancel the auto-timed program,
simply adjust the auto-off time to 0.0
DIRECT Button
Used to change the louver movement and set 0 the
desired up/down air flow direction. The louver changes
6° in angle for each press.
SWING Button
Used to stop or start horizontal louver auto swing
feature.
FOLLOW ME Button
Push this button to initiate the Follow Me feature, the
remote display is actual temperature at its location.
The remote control will send this signal to the air
conditioner every 3 minutes interval until press the
Follow Me button again. The air conditioner will cancel
the Follow Me feature automatically if it does not
receive the signal during any 7 minutes interval.
LED Button
Disable/Active indoor screen Display. When pushing
ON
the button, the indoor screen display is cleared, press
it again to light the display.
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
ControllerRemote controlRemote controlRemote controlRemote control
Room temperature
Cooling
Heating
Operation temperature62~8662~8662~8662~86
ºF
ºF
ºF
62~90
32~86
62~90
32~86
62~90
32~86
62~90
32~86
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
Refrigerant pipingLiquid side/ Gas side in3/8"/5/8"3/8"/5/8"
ControllerRemote ControlRemote Control
Room temperature
CoolingºF62~9062~90
HeatingºF32~8632~86
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without
notice and without obligation on our part. Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F