Before using your air conditioner, please read this manual carefully and keep it for future reference.
INVERTER SPLIT TYPE­ROOM AIR CONDITIONER
Read This Manual
Keep this manual where the operator can easily
find them.Inside you will find many helpful hints on how to use and maintain your air conditioner
properly. Just a little preventative care on your
part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review the chart of Troubleshooting Tips first, you may not need to call for service.
Page 2
CONTENTS
SAFETY PRECAUTIONS
Warning .................. .... ................. ................................................. .............. ........................... ....3
Caution ...... ........................... ............... ............. .... ...... ................................ ........................... ....4
.
NAMES OF PARTS
Indoor unit . .......... .. .............. ............................ .... ................. ..................... ........................... ....5
outdoor unit ............. ................ ...... ................................. ........................... .... ................. ...........5
Indication la mp......... ......................................... .............. ...........................................................5
OPERATING INSTRUCTIONS
Special functions .............................................. ................ ............ ..... ........................................6
Operating temperature........... ............................ .......................................... .................... ....... ....7
Manual oper ation ... .............. ............................ ..................... ...... ............................ .............. ....7
Airflow direction control ..................... ............................ .............. ............. ......... ...... .................8
How the air conditioner works ......................... .... ................. ................................................ ....9
CARE AND MAINTENANCE
Before maint enance...... ........ ........... ................. ............................ .............. ..... ...................... ..10
Cleaning the unit...... ............................ ............... ............ ............................ ............... ...............10
Cleaning the air filter and ai r f reshening filter ............................... .............. ............. .... ............10
Replacement of the a ir filter and air fre shening filter ........ ...... ...... ........................... ................11
Preparation for extended non-operation.................. ....................... ........................... .............. ..11
Pre-season inspection.......................... ........................... ..................... .....................................11
TROUBLESHOOTING TIPS
Normal function of the air conditioner................. ............. .... ...... ................. ............... ...............12
Troubleshoot ing guide .......... ....................... ..... ............................ .............. ............. .... ...... ......14
Page 3
When using thi s air conditioner in the European countries, please read the following information:
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least
free of charge.
C) The manufacturer will take back the old appliance for disposal at least free of
charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal
dealers. Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
Page 4
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
WARNING
CAUTION
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Strictly prohibited.
Be sure to follow the instructions.
WARNING
Do not extend the cable and never use multiple plugs. A poor electrical connection, poor insulation or voltage which is higher than permitted can cause fire. Do not expose your body directly to the cool air for prolonged period. Never poke fingers, sticks or other objects in the air inlet and outlet vents. Never attempt to repair, relocate, modify the air conditioner yourself. Always contact your service partner if it requires. Never pull the plug out by pulling on the cable. Hold the plug firmly and pull it out of the plug socket, otherwise there is a risk of damaging the cable.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
Remove all dirt from the power plug and plug it firmly. Soiled plugs can cause fire or an electric shock. In the event of any abnormalities such as smell of burning, immediately switch off the device and pull the plug. Contact your service partner. Always switch off the device and pull the plug before you start to clean it.
Use specified power cord.
Contact the authorized installer for installation of this unit. Contact an authorized service technician for repair or maintenance of this unit. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the air conditioner.
Page 5
CAUTION
SAFETY PRECAUTIONS
Never actuate any switches with a wet hand. It may cause an electric shock. Never use the device for any other purpose than the intended use. Never place food, precision instruments, plants, animals, paint, etc. on the unit. Do not expose plants or animals directly to the air flow. Never clean the air conditioner with water. Never use combustible cleaning agents as these could cause a fire or deformation. Never place any burning objects close to the device if they could be directly affected by the emitted air. Never step onto the outdoor device and never place anything on it. Never use an unsteady or rusty base. Never install the air conditioner in places where combustible gas can be emitted. Emmitted gas may collect and cause an explosion. Never allow the air conditioner to run for too long with the doors or windows open, or if the humidity is very high.
If the air conditioner is to be used in conjunction with other heaters, the air should be refreshed periodically, o therwise there is a risk of lack of oxygen. Always pull out the power plug if the unit is not going to be used for any lengthy period of time. Collections of dust can cause fire. Always switch off the air conditioner and pull out the power plug during a storm. Electrical parts may get damaged. Check that the drainage line is correctly connected. If not, water will escape. Check that the condensation water can run off unhindered. It may cause water damage if the condensation water cannot run off properly. The air conditoner must be earthed in accordance with the local codes. For electrical safety purposes we recommend that you install an earth­leakage circuit-breaker.
If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similary qualified persons in order to avoid a hazard.
Page 6
NAMES OF PARTS
Indoor u nit
Outdoor unit
Indication lamp
Signal receiver
Names of parts
Indoor u nit
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5.
Horizontal air flow grille
6.
8
9
10
Vertical air flow louver(inside)
7. Display panel
Outdoor unit
8. Connecting
9. Connecting
10. Stop valve
NOTE:
All the pictures in this manual are for explanation purposes only. of the indoor unit you purchased may be slight different on front panel and display window. actual shape shall prevail.
pipe cable
The actual shape
The
Indication lamp
ION i n dicati on lamp(o ptional f unction )
This lamp illum inates when Clean Air feature is activated.
DEFROST indication lamp
(Enabled on coo ling & heating models only):
Lights up
defrosting automatically or when the warm air control feature is activated in he ating operation.
OPER ATION indica tion lam p
when the air conditioner starts
This lamp illum inates when the air conditioner is in operation.
TIMER indic ation la mp
Lights up during Timer operation.
Temperature indicator
Displays the temperature settings when the air conditioner is operational. Displays the malfunction code.
Page 7
Special functions
OPERATING IN STRUCTIO NS
Refrig era nt Lea kage De tec ti on
With t his new technology, the dipsplay area will appe ar EC and the indicatio n lamps
,
,
contin ue fl ashing when the outdoor unit detects refrig erant leakage.
Louver Ang le M emor y Function( op ti on a l) :
Within t he sco pe of s af e ty angle, it will m em ori ze th e op en ang le o f ho riz on tal louve r. If i t exceeds, it will m em ori ze the boundry o f saf et y angle. In t he fo llowing circ umst an ces , it will retur n to sta nd ard angle: 1) pre ssing t he ma nu al swi tch , 2) un plug and th en plu g in the m ac hi ne. So we s trongly s ugg est th at the open a ng l e of the horizon tal louve r sh ould
not be s et t oo smal l, i n cas e th e conde nsed water fo rms and d ro ps from t he horizon tal louve r.
SELF CL EAN fu nction Op tio nal
F un cti on u sed after the Shut Do wn o f coo ling op er a tio n to c lea n the Evapo ra tor a nd ke ep it as fre s h for t he next op era tion. T he unit wi ll oper at e as fo llowi ng s eq uenc e : FAN ONLY mo de at Lo w f an sp eed--H e ating o pe ration w ith LO W fa n sp eed(appl i cab le t o coolin g & heati ng mod l es only) --- FAN O NLY o pe ration --St op Op erat io n --- Turn o ff .
Not e:
T his func tio n is only av ai labl e under COOL ( AUTO COOL, F OR CE D C OOL) a nd DRY mode. Bef ore se lect the function , it i s recom men d ed to ru n t he air c on dition e r unde r Cooling o pe ration for ab o ut hal f an h our. Once the Sel f Clea n f unct ion i s acti v ated, all T IMER set ting w ill be cancelle d. During Se l f Cle an operat i on, whe n pr ess th e SELF CLEAN button on the r e m ote contr olle r agai n w ill stop t he opera tion and t ur n off the un it automa tically.
CLEAN AIR fun c tion(on so me m od el s )
This air conditioner is equ ipp ed with ionizer or Plasma D ust Collector(Depending o n specific configuration of the mode l). With the anions gen erat ed by Io nize r, the air ci rcula tion of the air conditioner fill s the room with refreshing, nat ural and healthy air. The Plasm a Dust C ollector generates a high volta ge ioni zation zone, through which t he air is converted to plas ma. Ins ide
the ai r most of the du st, s moke, and poll en particles are capture d by th e electro static filter.
An t i- milde w f unct i on Opti ona l
When t urns off the unit on COOL, DRY, AUTO (Cool) mode, the air condit ioner will continue opera ting for abo ut 7-10 min utes (depending on models) at LOW f an speed. If turns off on HEAT mode, the uni t will continue opera ting for abo ut 30 secon ds at LOW fan speed. This wil l help to dry up the co nde nsed water insi de the e vap orat or, and prev ent the breedin g of mildew. Unde r Anti-mildew operation, do no t restart the air cond itioner unti l the unit is compl etely off.
Vert ica l s wi ng func tion O ptional
After the AC starts up, users can control the vertical louver swing by the remote controller.
Page 8
OPERATING INSTRUCTIONS
NO TE: This man ua l does no t include Re mo t e C ont ro ller O per ati on s, se e the << R emote Cont rol le r In struc t io n> > pa cke d w ith the uni t f o r d eta il s .
Operating temperature
Temperature
Mode
Room temperature
Out door te mperature
Cooling operat i on Heat ing opera tio n Drying operation
O O
17 C~32 C
O O
(62 F~9 0 F)
O O
0 C~30 C
O O
(32 F~8 6 F)
10 C~3 2 C (50 F~90 F)
0 50
32 122
-15 50 5 122
For the models with low
temperat ure cooli ng syste m
-15 30 5 86
0 50
32 122
O O
O O
NOTE:
1. Optimum performance will b e achiev ed within these operating tempera tures.If air co nditione r is used outside of the ab ove conditions, ce rtain saf ety prote c tion features might come into op eration and cause the unit to funct ion abno rmally.
2. If the air co nditione r runs for a long time in co oling mo de and th e humid ity is high(over 80 %) , con densed w ater ma y drip out of the unit . Please sets the vertical air flow louver t o its ma ximu m angle (vertical ly to the f loor), an d set HIGH fan mode.
Sug gestion : For the uni t ado pts an E lectric He ater, whe n the ou tsi de am bient temperature
is below 0 C(32 F), we strong ly recom mend yo u to keep the machine plu gg ed in order to
O O
guarantee it running s moothly.
Manual operation
Units are equipped with a swi tch to r un emergency operatio n mode. It can be accessed by opening the front panel. This s witch is used for manua l operat ion in case the rem ote cont roller fails to wo rk or ma intenance necessary.
NOT E: T h e unit m u st be tu rned off b ef ore o pe ra ting the man ual co nt rol butto n. If the u ni t is op e rat ion al , co ntinu e pr essi n g the m anual control b u tton unt i l the un it is off.
Open and lift the fron t panel up to an ang le
1
until it rem ain s fix ed with a c lick ing sound. For some mo dels , please use sus pension bars t o prop up the panel .
2
One press of the man ual control swi tch w ill lead to the forced AUTO ope ratio n. If press the switch t wice within fiv e seconds, the unit will operate under forced COOL operation . Close the panel f irmly to its or iginal
3
position.
CAUTION:
This swi tch is used for t estin g purposes
only. You ha d better not cho ose it.
To restore the remote controller ope ration, use t he remote cont rolle r di rect ly.
Manual control button
Manual switch
( )1
Manual control button
Manual switch
( )2
AU TO/CO OL
Suspension bars
AU TO/C OOL
Page 9
Airflow direction control
Range
Defle ctor ro d
R ange
OPERATING IN STRUCTIO NS
Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures. Adjust the horizontal/vertical louver using the remote controller. For some models, the vertical louver can only be adjusted manually.
To set the horizontal/vertical air flow directio n
Perform this function while th e unit is in operation. Use the remote controller to adjust the air flow direction. The vertical/horizontal louver changes 6 degree in angle
for each press, or swing up and down automatically. Please refer to the REMOTE CONTROLLER OPERATION
,,
MANUAL for details. For some models, the vertical louver can only be adjusted manually. Move the deflector rod man ually to adjust the air flow in the direction you prefer.
IMPORTANT
blower and suction side.
cause danger.
,,
:Do not put your fingers into the panel of
The high-speed fan inside may
CAUTION
Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode. Otherwise, condensation may occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings. When the air conditioner is started immed iately after it was stopped, the horizontal louver might not move for approximately 10 seconds. Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area. Do not move the horizontal louver manually, otherwise
the horizontal louver will be out of sync. Please cease operating, unplug power for a few seconds,then restart the air conditioner. Do not operate unit with horizontal louver in closed position.
Page 10
OPERATING INSTRUCTIONS
How the air conditioner works
SLEEP operation
Set Temper ature
1 hour
Cooli ng
SLEEP operation
Set Tempe ra t ure
1 ho ur
Hea t i ng
7 hour s timer off
1 ho ur
7 hou rs timer o ff
1 hour
AUTO operation
When you set th e air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on set temperature and the room temperature. The air conditioner will control room temperature automatically to the temperature point you se t. If you feel uncomfortable in the AUTO mode, you can set your desired temperature.
SLEEP operation
When you push SLEEP button on remote controller during cooling, heating(cooling & heating models only), or AUTO operation , the air conditioner will automatically increase (cooling) or decrease (heating)
per hour for the first 2 hours, then hold steadily for the n ext 5 hours, after th at it will switch off. This mode saves you energy and b rings you comfort at night.
DRYING operation
The fan speed w ill be automatically controlled under dry operation. During the dry operation, if the room temperature is lower than 10 C(50 F), the compressor stops operation and restarts until the room temperature is above
O O
12 C(54 F).
O O
Optimal operation
To achieve optimal performance, please note the following: Adjust the air flow direction correctly so that it is not forwards people. Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. Close doors and windows on COOL or HEAT modes, or performance may be reduced. Use TIMER ON button on the remote controller to select a time you want to start your air conditioner. Do not put any object near air inlet or air outl et, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running. Clean the air filter periodically, otherwise cooling or heating performance may be reduced. Do not operate unit with horizontal louvre in closed position.
Page 11
Care and Maintenance
Filter Handle
CARE A ND MAINTENANCE
Before mainatenance
Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
NOTE: Power supply must be disconnectd before cleaning the indoor unit.
CAUTIONS
A cloth dampened with cold water may be used on the ind oor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit. Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause
the plastic surface to crack or deform. Never use water hotter than 40 C/104 F to clean the front panel, it c ould cause deformation of discoloration.
Cleaning the unit
wipe the unit with a soft dry cloth only. If the unit is very dirty, wipe it with a cloth soaked in wa rm water.
Cleaning the air filter a nd air freshening filter
A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it
stops with a clicking sound.For some models, please use suspension bars to prop up the panel.
2. Take hold of the handle of the air filter and lift it
up slightly to take it o ut from the filter holder, then pull it d ownwards.
3. Remove the AIR FILTER from the indoor unit.
Clean the AIR FILTER once two weeks. Clean the AIR FILTER with a vacuum cleaner or water, then dry it up in cool place.
Page 12
CARE AND MAINTENANCE
1
Plas ma
Hol d the tw op arts of P lasma w here ar e ma rke d with sig nal a nd li ft it. Th en you ca n ope n the cov er of th e th e plas ma and rem ove th e f ilter.
Air fi lter
2
4. Remove the Air Freshening Filters from its supporting frame (The solution to disassemble may differ from
1
each other for different filters. Refer to and ).
2
Clean the air freshening filter at least once a month, and replace it every 4-5 months . Clean it with vacuum cleaner, th en dry it in cool place. For the models with plasma, do not touch the plasma within 10 minutes after you open the panel.
5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the unit, taking care that the left and right edges line up correctly and place filter into position.
Replacement of air filter and air freshening filter
1. Remove the air filter.
2. Remove the air freshening filter.
3. Install a new air freshening filter.
4. Reinstall the air filter and securely close the front panel.
Preparation for extended non-operation
If you plan to idle the unit for a long time, perform the following:
(1) Clean the indoor unit and filters.
Operate the fan for about half a day to dry the
(2)
inside of the unit.
Stop the air conditioner and disconnect power.
(3)
Remove the batteries from the remote controller.
(4)
The outdoor unit requires periodic maintenance and cleaning. Do not attempt to do this yourself. Contact your dealer or service provider.
Pre-season inspection
Check that the wiring is not broken off or disconnected. Clean the indoor unit a nd filters. Check that the air filter is installed. Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time.
Cauti on
Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. When cleaning the unit, first make sure that the power and circuit breaker are turned off. Do not wash air filter with hot water at more than 40 C . Shake off moisture completely and dry
O
/104 F
O
it in the shade. Do not expose it directly to the sun, it may shrink.
Page 13
TROUBLESHO OTING TIPS
Normal function of the air conditioner
The following events may occur during normal operation.
1.
Protection of the air conditioner.
Compressor protection
The compressor can't restart for 3-4 minutes after it stops.
Anti-cold air (Cooling and heating models only)
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
A) When heating has just started.
B) Defrosting. C) Low temperature heating. The indoor or outdoor fan stop running wh en defrosting (Cooling and heating m odels only).
Defrosting (Cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner. During this condition air conditioner will stop heating operation and start defrosting automatically. The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and
the amount of frost built up on the outdoor unit.
2.
A white mist coming out from the indoor unit
A white mist may generate due to a large temperature difference between air inlet and air outlet
on COOL mode in an indoor environment that has a high relative humidity.
A white mist may generate due to moisture generated from defrosting process when the air
conditioner restarts in HEAT mode operation after defrosting.
3.
Low noise of the air conditioner
You may hear a low hissing sound when the compressor is running or has just stopped running. It is the sound of the refrigerant flowing or coming to a stop. You can also hear a low "squeak" sound when the compress or is running or has just stopped running. This is caused by heat expansion and cold contraction of the plastic pa rts in the unit when the temperature is changing.
A noise may be heard due to louver restoring to its original p osition when power is turned on.
4.
Dust is blown out from the indoor unit.
This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit.
5.
A peculiar smell comes out from the indoor unit.
This is caused by the indoor unit giving off smells permeated from building material, from furniture, or smoke.
6.
The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and
heating models only) mode.
When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models only) to the set point.
Page 14
TROUBLESHOOTING TIPS
7. The air conditioner runs function after turning off the unit.
Anti-mildew
When turning off the unit under COOL(AUTO COOL, FORCED COOL) and DRY mode, the air
conditioner will run function for 7-10 minutes,
Anti-mildew
continue operating for about 30 seconds at LOW fan speed,
if turns off on HEAT mode, the unit will
then stop the operation and turn
off the unit automatically.
8. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed.
9.
Heating mode (For cooling and heating models only)
The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature. If a comfortable temperature can't be achieved by the air conditioner, we suggest you use a supplementary heating device.
10.
Auto-restart function
Power failure during operation will stop the unit completely. For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the
remote controller. For the unit with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function.
Page 15
Troubleshooting guide
OPERATION(RUN) indicator o r other indicators continue flashing.
If one of the following code appears on the
Trouble
Unit does not
start
display area :
P3...., or F0,F1,F2,F3.......
Fuse blows frequently or circuit breaker trips frequently .
Other objects or water fall into the air conditioner.
Terrible odors are smelled or abnormal sounds are heard.
Malfunctions
E0,E1,E2,E3....., P0,P1,P2,
Power cut
Unit may have become
Fuse may have blown.
Battery in Remote controller may have been exhausted.
Cause
Unplugged.
TROUBLESHOOTING TIPS
The unit may stop operation or continue to run in a safety condition(depending on models). Waiting for about 10 minutes, the fault may be recovered automatically, if not, disconnect the power and then connect it in again. If the problem still exists, disconnect the power and contact the nearest customer service center.
Stop the air conditioner immediately, disconnect the power a nd contact the nearest customer servi ce center.
What should be d one?
Wait for power to be restored.
Check that plug is securely in wall
receptacle.
Replace the fuse.
Replace the battery.
The time you have set with timer
is incorrect.
Unit not cooling
or heating
(Cooling/ heating
models only)
room very well
while air flowing
out from the air
cond tioneri
If the trouble has not been corrected, please contact a local dealer or the nearest customer
service center. Be sure to inform them of the detailed malfunctions and unit model number.
Notes: Do not attempt to repair the unit yourself.
Always consult an authorized service provider.
Inappropriate temperature
setting.
Air filter is blocked.
Doors or Windows are open.
Air inlet or outlet of indoor or outdoor unit has been blocked.
Compressor 3 minutes
protection has been activated.
Wait or cancel timer setting.
Set temperature correctly. For
detailed method please refer to
" "Using remote control section.
Clean the air filter.
Close the doors or windows.
Clear obstructions away first, then
restart the unit.
Wait.
Page 16
The Klimaire logo is a registered Trademark of Klimaire Products inc.
Copyright 2014 Klimaire Products Inc.
2190 NW 89 Place, Doral, FL 33172 - USA
Tel: (305)593-8358 Fax (305) 675-2212
www.klimaire.com sales@klimaire.com
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.