Klimaire KSIL036H215 User Manual

CONTENTS
1. Precaution .................................................................................................................................................... 1
1.1 Safety Precaution .......................................................................................................................... 1
1.2 Warning ......................................................................................................................................... 1
2. Function ........................................................................................................................................................ 6
3.1 Indoor Units ................................................................................................................................... 9
3.2 Outdoor Units ............................................................................................................................... 11
4. Refrigerant Cycle Diagram ....................................................................................................................... 12
5. Wiring Diagram .......................................................................................................................................... 14
5.1 Indoor Units ................................................................................................................................. 14
5.2 Outdoor Units .............................................................................................................................. 17
6. Installation details ...................................................................................................................................... 21
6.1 Wrench torque sheet for installation ........................................................................................... 21
6.2 Connecting the cables ................................................................................................................ 22
6.3 Pipe length and the elevation ..................................................................................................... 23
6.4 Installation for the first time ......................................................................................................... 24
6.5 Adding the refrigerant after running the system for many years ................................................ 27
6.6 Re-installation while the indoor unit need to be repaired ........................................................... 28
6.7 Re-installation while the outdoor unit need to be repaired ......................................................... 30
7. Operation characteristics ......................................................................................................................... 33
8. Electronic function .................................................................................................................................... 34
8.1 Abbreviation ................................................................................................................................ 34
8.2 Display function ........................................................................................................................... 34
8.3 Main Protection ........................................................................................................................... 35
8.4 Operation Modes and Functions ................................................................................................. 36
9. Troubleshooting ......................................................................................................................................... 50
9.1 Indoor Unit Error Display ............................................................................................................. 50
9.2 Diagnosis and Solution ............................................................................................................... 51
1. Precaution
1.1 Safety Precaution
To prevent injury to the user or other people and property damage, the following
instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. Before service unit, be sure to read this service manual at first.
1.2 Warning
Installation
Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated
circuit.
There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized
service center.
Do not disassemble or repair the product, there is risk of fire or electric shock.
Always ground the product.
There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
There is risk of fire of electric shock.
Always install a dedicated circuit and breaker.
Improper wiring or installation may cause fore or electric shock.
Use the correctly rated breaker of fuse.
There is risk of fire or electric shock.
Do not modify or extend the power cable.
There is risk of fire or electric shock.
Do not install, remove, or reinstall the unit by yourself(customer).
There is risk of fire, electric shock, explosion, or injury.
Be caution when unpacking and installing the product.
Sharp edges could cause injury, be especially careful of the case edges and the fins on the
1
2
condenser and evaporator.
For installation, always contact the dealer or an Authorized service center.
There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Do not let the air conditioner run for a long time when the humidity is very high and a
door or a window is left open.
Moisture may condense and wet or damage furniture.
Take care to ensure that power cable could not be pulled out or damaged during
operation.
There is risk of fire or electric shock.
Do not place anything on the power cable.
There is risk of fire or electric shock.
Do not plug or unplug the power supply plug during operation.
There is risk of fire or electric shock.
Do not touch (operation) the product with wet hands.
There is risk of fire or electric shock.
Do not place a heater or other appliance near the power cable.
There is risk of fire and electric shock.
Do not allow water to run into electric parts.
It may cause fire, failure of the product, or electric shock.
Do not store or use flammable gas or combustible near the product.
There is risk of fire or failure of product.
Do not use the product in a tightly closed space for a long time.
Oxygen deficiency could occur.
When flammable gas leaks, turn off the gas and open a window for ventilation before
turn the product on.
Do not use the telephone or turn switches on or off.
3
There is risk of explosion or fire.
If strange sounds, or small or smoke comes from product. Turn the breaker off or
disconnect the power supply cable.
There is risk of electric shock or fire.
Stop operation and close the window in storm or hurricane. If possible, remove the
product from the window before the hurricane arrives.
There is risk of property damage, failure of product, or electric shock.
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic
filter, if the unit is so equipped.)
There is risk of physical injury, electric shock, or product failure.
When the product is soaked (flooded or submerged), contact an Authorized service
center.
There is risk of fire or electric shock.
Be caution that water could not enter the product.
There is risk of fire, electric shock, or product damage.
Ventilate the product from time to time when operating it together with a stove, etc.
There is risk of fire or electric shock.
Turn the main power off when cleaning or maintaining the product.
There is risk of electric shock.
When the product is not be used for a long time, disconnect the power supply plug or
turn off the breaker.
There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
This could result in personal injury and product damage.
CAUTION
Always check for gas (refrigerant) leakage after installation or repair of product.
Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that water is drained away properly.
A bad connection may cause water leakage.
4
Keep level even when installing the product.
It can avoid vibration of water leakage.
Do not install the product where the noise or hot air from the outdoor unit could damage
the neighborhoods.
It may cause a problem for your neighbors.
Use two or more people to lift and transport the product.
Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
Operational
Do not expose the skin directly to cool air for long periods of time. (Do not sit in the
draft).
This could harm to your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc.
It is a consumer air conditioner, not a precision refrigerant system.
There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very
sharp.
There is risk of personal injury.
Do not step on or put anything on the product. (outdoor units)
There is risk of personal injury and failure of product.
Always insert the filter securely. Clean the filter every two weeks or more often if
necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or
5
damage.
Do not insert hands or other object through air inlet or outlet while the product is
operated.
There are sharp and moving parts that could cause personal injury.
Do not drink the water drained from the product.
It is not sanitary could cause serious health issues.
Use a firm stool or ladder when cleaning or maintaining the product.
Be careful and avoid personal injury.
Replace the all batteries in the remote control with new ones of the same type. Do not
mix old and mew batteries or different types of batteries.
There is risk of fire or explosion.
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
They may burn of explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean
water. Do not use the remote of the batteries have leaked.
The chemical in batteries could cause burns or other health hazards
6
2. Function
Model Names of Indoor/Outdoor Units
DC Inverter
Capacity
9K
12K
18K
24K KSIL024-H216 KSIL024-H216 KSIL024-H216
Model Indoor units Outdoor units
KSIL009-H216 KSIL009-H216 KSIL009-H216 KSIL009-H119 KSIL009-H119 KSIL009-H119 KSIL012-H216 KSIL012-H216 KSIL012-H216 KSIL012-H219 KSIL012-H219 KSIL012-H219 KSIL018-H216 KSIL018-H216 KSIL018-H216 KSIL018-H219 KSIL018-H219 KSIL018-H219
7
The louver can be set at the desired position
The function is usually used in ra
iny
The unit will decide the louver direction according
Turbo, high, med, low, breeze.
Prevent the water being fr
ozen
on evaporator by
Prevent the cold wind at the
Indoor unit
Operation by remote controller
Anti-freezing control in cooling
checking the evaporator pipe temperature
Time Delay Safety control
Indoor fan speed control
Two-direction air vane
to operation mode.
Sleep mode auto control
Independent dehumidification
days in springtime or damp areas.
Golden fin (Optional)
Ionizer + (Optional)
Current protection
Low ambient cooling (Optional)
Self-diag. function
Anti-cold function
beginning of unit start.
Air flow Direction
or swing up and down automatically
Auto mode
Temp. Compensation
Auto defrost
Auto-restart
Flexible wiring connection
8
It protects the valves and prevents water from dripping.
The unit has 3 mins delay between continuously ON/OFF operations.
The hydrophilic fin can improve the heating efficienc
y at operation mode.
It is only operated in the heating operation mode except defrosting operation.
Made from electrolytic zinc steel sheet and anti
-
rust coated components.
Bird tail propeller fan makes the outdoor unit run more quietly.
Outdoor unit
Power relay control
Low noise air flow system
Hydrophilic aluminum fin
4 way valve control
Anti-rust cabinet
Valve protection
PTC heater (Optional)
9
3. Dimension
3.1 Indoor Units
Model W H D KSIL009-H116 790 (31.1 in) 265 (10.4 in) 198 (7.8 in) KSIL009-H119
KSIL012-H216 KSIL012-H219 KSIL018-H216 KSIL018-H129 KSIL024-H216
920 (36.2 in) 292 (11.5 in) 223 (8.8 in)
998 (39.3 in) 322 (12.7 in) 240 (9.4 in)
10
For the other models
11
3.2 Outdoor Units
More than 30cm
F
e
n
c
e
o
b
o
s
r
t
a
c
l
e
s
More than 60cm
More than 30cm
More than 60cm
More than 70cm
(Service space)
Model W D H W1 A B
9K/12K 760 285 590 823 530 290
18K
845 320 700 908 560 335
24K 900 315 860 980 590 333
12
INDOOR
OUTDOOR
4. Refrigerant Cycle Diagram
For cooling only models:
LIQUID SIDE
CAPILIARY TUBE
HEAT EXCHANGE (EVAPORATOR)
GAS SIDE
HEAT EXCHANGE (CONDENSER)
COMPRESSOR
13
INDOOR
OUTDOOR
For heat pump models:
HEAT EXCHANGE (EVAPORATOR)
LIQUID SIDE
2-WAY VALVE
GAS SIDE
3-WAY VALVE
CHECK VALVE (Heating Model only)
CAPILIARY TUBE
ACCUMULATOR
HEAT EXCHANGE (CONDENSER)
REVERSING VALVE (Heating Model only)
COOLING
COMPRESSOR
HEATING
14
5. Wiring Diagram
5.1 Indoor Units
KSIL009-H116, KSIL012-H216, KSIL012-H219
KSIL009-H119
15
KSIL018-H216, KSIL018-H219, KSIL024-H216
16
KSIL009-H119
KSIL012-H119
Loading...