Overview
Standard Features
KSIH Series
20-25 SEER
Klimaire KSIH Heat Pump
for extreme winter - Up to 100% heating
capacity at 5º F (-15º C) and operates
efficiently as low as -13º F ambient
temperature.
Low Ambient Cooling
Operates in cooling mode in the low winter
ambient conditions down to 5° F when
cooling is necessary in spaces like server
rooms, sun rooms & hydroponic labs.
Energy efficiency
Up to 25 SEER
Auto Restart Auto Defrosting
Timer
46ºF Heating
Turbo Mode
Golden Fin - Anticorrosion coating
to protect the outdoor coil from
corrosive elements to maintain higher
heat transfer for a longer time span.
Refrigerant Leakage Detection
You will be alerted when refrigerant
is low. Prevents damage to the
compressor by automatically turning
off the unit
Temperature
Compensation
Up to 100%
Cooling capacity
Anti-Cold-Air
(Heat Pump Only)
Outdoor
Metal Grill
Cold Catalyst
Filter
Follow me
Self-Cleaning - Your Klimaire KSIH series
equipped with Auto Clean Function.
It cleans and dries the evaporator to prevent
mildew grow and odor to keep it fresh
for next operation
Enhance base plate design
For optimal condensate drainage to reduce
ice build-up and keep efficiency high at low
ambient temperature.
Self-Cleaning
Self Diagnostic
Service
Sleep Mode
Crankcase
Heater
Silent Mode
Low Noise Airflow
5 Grades OD
Fan Speed
Memory
2 ways drainingLouver Position
12 Grades
ID Fan Speed
Outdoor Unit
Pan Heater
High Density
Washable Air Filter
KSIH ductless mini split systems can be an energy-saving,
cost-effective solution for a variety of applications:
· New construction and renovations
· Homes and businesses
· Single or multi family
2
· Primary living areas
· Rooms that are always too hot or too cold
· Basements, attics, garages, additions
Mark of Superior Quality

Remotely managed
iOS or Android APP
Room by Room
Optional Smart Kit
iOS and
Android APPS
KSIH Series
20-25 SEER
78 %18:30
F
75°
COOL
Individual Comfort and
Temperature Control
Create your own true zone cooling
& heating to achieve more precise
individual comfort day and night in
your home or business. Klimaire
units zoning capability allows you
to set each zone with different
temperature settings as desired.
You can even turn off the units in
non-occupied rooms for additional
energy savings, while keeping
them at a higher temperature
setting in cooling to control
humidity levels – increasing
personal comfort.
Accessories
76
69
70
70
73
1
2
115 - 230 V
Condensate Drain
Outdoor unit wall brackets
Mini-Pumps
3
Mark of Superior Quality

Turbo Mode 12 Grades Fan Speed Follow-me
8
7
6
5
4
3
2
1
9
10
11
STANDARD SENSOR LOCATION BUILD-IN SENSOR
28º
12
KSIH Series
20-25 SEER
23º
23º
23º
23º
Sleep Mode
Low Noise Design
Optimize air discharge vane
Silent Mode
Self Cleaning
ON / OFF 24 hr. Programmable Timer
OFF
3 hr.
M ax
Decrease
3.5dB(A )
Indoor fan run at an
extra breeze
Operation
Time
(minute)
Low Fan
Only
1-13
Heating
& Low Fan
14
Low Fan
Only
15-16
During DayDuring Night
12
12
AUTO
9 PM
Set
7
ON
10 hr.
Set your confort
preferences
4
39
6
ON/OFF
MODE
SILENCE
FP
TEMP
TIMER
ON
SLEEP
TIMER
OFF
TURBO
SWING
SELF
CLEAN
DIRECT
LED
FOLLOW
ME
TIMER
ON
TIMER
OFF
OFF
11 hr.
7
6
ON
Set your confort
preferences
Mark of Superior Quality
39

Ductless Mini-split
Auto Re-start
UNIT
RUNNING
KSIH Series
20-25 SEER
POWER
OUTAGE
Personalized Comfort Solution
Experience true individual comfort. Ductless Mini-Split systems are
the perfect solution to a variety of installation challenges. Ductless
Mini-Split units eliminate the use of ductwork, allowing installers the
ability to place these units in locations that were previously
considered impractical or impossible due to additional ducting and
cost associated with installing a regular unit. Ductless Mini-Splits
consist of two parts, an outdoor unit and an indoor unit, similar to
regular split units, but much smaller in size. The outdoor and indoor
units are connected to each other by refrigerant and electrical lines.
They run together with a condensate drain line through a small hole in
an exterior wall, generally 3 inch in diameter or less. In addition to
eliminating the need for ducting, another great advantage of Ductless
Mini-Split systems is true zone control. The indoor fan coil unit is
dedicated to the room being conditioned, allowing a temperature and
humidity level to be kept in a specific room, separate from the rest of
the house or building.
Reliability
Base Pan
Heater
Indoor Unit / Evaporator
Conduit for
Refrigerant
Lines
& Wiring
Outdoor Unit
/ Condenser
Compressor
TwinCam
Heater
Prevents defrost condensation
from freazing ensuring proper defrost
drainage during heating season
5
Ensures Compressor
longevity and reliability
A high performance double cam
twin rotary compressor increases the
performance, reliability and durability
Mark of Superior Quality

Remote Control
1
ON/OFF Button
This button turns the air conditioner ON
and OFF.
2
MODE Button
Press this button to modify the air conditioner
mode in a sequence of following:
NOTE: Please do not select HEAT mode if the
machine you purchased is cooling only type.
Heat mode is not supported by the cooling
only appliance.
3
COOL
DRY
AUTO
KSIH Series
20-25 SEER
8
SILENCE/FP Button
Active/Disable SILENCE function. If pushing
more than 2 seconds, the “FP” function will
be activated, pushing more than 2 seconds
again to disable.
4
For the detail, see “sleep operation” in
“USER´S MANUAL”.
NOTE: While the unit is running under SLEEP
mode, it would be cancelled if MODE, F
SPEED or ON/OFF button is pressed.
5
6
SELF CLEAN Button
Active/Disable Self Clean function.
Under SELF CLEAN mode, the air
conditioner will automatically clean and dry
the Evaporator and keep it as fresh for the
next operation.
7
o
DOWN Button ( )
Push this button to decrease the indoor
temperature setting in 1F increments to 62ºF.
NOTE: Temperature contol is not available
in Fan mode.
NOTE: Press and hold UP and DOWN buttons
together for 3 seconds will alternate the temperature display between the ºC & ºF scale.
o
AN
FAN
AUTO
7
9
TIMER ON Button
Press this button to initiate the auto-on
1
2
ON/OFF
MODE
TEMP
3
4
SLEEP
SILENCE
FP
TIMER
ON
TIMER
OFF
SWING DIRECT
8
9
10
11
time sequence. Each press will increase
the auto-timed setting in 30 minutes
increments. When the setting time displays
10.0, each press will increase the autotimed setting 60 minutes increments.
To cancel the auto-timed program, simply
adjust the auto-on time to 0.0.
10
12
SELF
TURBO
5
CLEAN
6
LED
FOLLOW
ME
13
14
11
SWING Button
Used to stop or start horizontal louver auto
swing feature.
12
O
13
FOLLOW ME Button
Push this button to initiate the Follow Me
feature, the remote display is actual
temperature at its location. The remote
control will send this signal to the air
conditioner every 3 minutes interval until
press the Follow Me button again. The air
conditioner will cancel the Follow Me feature
automatically if it does not receive the signal
during any 7 minutes interval.
14
KSIH Product Code
K S I
K: Klimaire
6
Product Series
H
Nominal Capacity
009: 9,000 Btu/h
012: 12,000 Btu/h
018: 18,000 Btu/h
024: 24,000 Btu/h
H 2 20–018 I W
SEER
1 : 115 / 60
H: Heat Pump
C: Cooling Only
2 : 208-230 / 1 / 60
–
I: Indoor Unit
A1
(If any)
Wi Fi
Mark of Superior Quality

KSIH Series
20-25 SEER
Indoor KSIH009-H225-IW KSIH012-H222-IW KSIH018-H220-IW KSIH024-H220-IW
Power supply
Cooling
Heating Input W 835 975 1685 2500
Minimum Circuit Ampacity - MCA A 9 9 18 20
Maximum Fuse Size - MOCP A 15 15 25 30
Compressor Input W 858 870 1970 1970
Indoor fan motor RLA A 0,06 0,06 0,13 0,3
Indoor noise level (Hi/Mi/Lo)
Indoor unit Packing (W*D*H) in 35.83x10.63x13.98 35.83x10.63x13.98 41.93x11.81x15.75 49.80x13.39x16.53
Outdoor fan motor
Outdoor noise level
Outdoor unit Packing (W*D*H) in 36.2x15.4x24.2 36.2x15.4x24.2 38x15.6x29.7 42.9x19.7x34.5
Refrigerant type
Refrigerant precharge
Additional charge for each ft
Design pressure
Refrigerant piping Max. refrigerant pipe length ft 82 82 98 164
Connection wiring / Stranded, unshielded
Thermostat type
Operation temperature
Application area (cooling standard)
Outdoor KSIH009-H225-O KSIH012-H222-O KSIH018-H220-O KSIH024-H220-O
V/ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Capacity rated
Min. - Max. rated
Input
Rated current
EER
SEER Btu/w 25 22,5 20 20,5
Capacity rated Btu/h 10900 11800 18000 24000
Min. - Max. rated Btu/h 4500-14500 5000-15500 5500-24000 6000-32000
Max. heating capacity @ 5/-5/-13 ºF
Rated current A 3,6 4,2 7,4 10,9
COP W/W 3,83 3,55 3,13 2,81
HSPF Btu/w 11,2 12 10,3 11,5
Type Rotary Rotary Rotary Rotary
Capacity Btu/h 11594 11430 24345 24345
Rated current (RLA) A 5,25 5,65 12,3 14
Refrigerant oil/oil charge ml Ester Oil VG74 / 500 Ester Oil VG74 / 500 POE (VG74) / 670 POE (VG74) / 670
Input W 50 50 58 (Output) 72
Speed(Hi/Mi/Lo) rpm 1170/900/700 1170/900/700 1100 / 900 / 700 1200/1100/900
Dimension(W*D*H) in 32.87x7.80x11.02 32.87x7.80x11.02 38.98x8.58x12.40 46.69x10.16x13.39
Net/Gross weight lb 19.84/25.35 19.84/26.68 26.89/34.83 40.12/50.26
RLA A 0,38 0,38 0,42 0,5
Dimension(W*D*H) in 31.5x13.1x21.8 31.5x13.1x21.8 33.3x14.3x27.6 37.2/16.1/31.9
Net/Gross weight lb 88.2/93.7 88.2/93.7 107.4/115.1 135.6/148.8
Liquid side/ Gas side in 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 3/8" / 5/8"
Outdoor (cooling/heating)-optional º F
Btu/h 9000 12000 17000 24000
Btu/h 3500-13000 4000-13800 4500-18800 5500-24500
W 620 960 1360 1920
A 2,7 4,2 5,95 8,4
Btu/w 14,5 13 12,5 13
Btu/h 12010/9650/9002 12000/9820/9010 18520/17010/16520 24030/21020/16520
cfm 418/324/247 418/324/247 599/411/353 794/647/500
dB(A) 42/33/24.5 43/36/24 45.5/36/26.5 47.5 /44/36.5
W
cfm 1120 1180 1355 2355
dB(A) 55,5 56 57,5 60
oz R410A / 52.9 R410A / 52.9 R410A / 68.8 R410A / 91.7
ft 25 25 25 25
oz 0,161 0,161 0,161 0,322
psig 550/340 550/340 550/340 550/340
ft 33 33 66 82
AWG x No. 16 x 4 16 x 4 16 x 4 16 x 4
º FIndoor (cooling/ heating)
sq. ft 129-189 172-252 258-376 344-505
63 63
Remote Control Remote Control Remote Control Remote Control
62~90/32~86
-22~122/-22~86
62~90/32~86
-22~122/-22~86
115/81/44 150Input
62~90/32~86
-22~122/-22~86
62~90/32~86
-22~122/-22~86
Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
6 in
H
7
W
D
H
W
Mark of Superior Quality
D