Klimaire KSIE024H220IW, KSIE024H220SW, KSIE012H120SW Specifications

SERIES
20-23 SEER
Klimaire Model Number - Indoor KSIE009-H121-I KSIE012-H120-I KSIE009-H221-I KSIE012-H220-I KSIE018-H220-I
Klimaire Model Number - Outdoor KSIE009-H121-O KSIE012-H120-O KSIE009-H221-O KSIE012-H220-O KSIE018-H220-O
Power supply
Cooling
Heating
Minimum Circuit ampacity A 15 15 15 15 15
Maximum Fuse Size
Compressor Capacity Btu/h 10014 11157 10014 11157 13836
Indoo fan motor Power Input W 20(Output) 20(Output) 20(Output) 20(Output) 58(Output)
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Indoor unit Packing (W*D*H) in 34.45x11.22x14.76 34.45x11.22x14.76 34.45x11.22x14.76 34.45x11.22x14.76 45.47x16.34x12.40
Outdoor fan motor Power Input W 40(Output) 40(Output) 40(Output) 40(Output) 50(Output)
Outdoor air flow
Outdoor noise level
Outdoor unit Packing (W*D*H) in 35.43x13.58x23.03 36.22x15.35x24.21 35.43x13.58x23.03 36.22x15.35x24.21 38.00x15.55x29.72
Refrigerant type
Refrigerant type / charge
Refrigerant precharge for up to
Additional charge per each ft
Design pressure
Refrigerant piping Max. refrigerant pipe length ft 82 82 82 82 98
Connection wiring
Thermostat type
Operation Indoor(cooling/ heating) 62~90/32~86
Temperature Outdoor(cooling/heating)-optional 5~122/5~86
Application area (cooling standard)
Capacity Btu/h 9000 12000 9000 12000 18000
Power Input W 665 960 640 923 1384
Rated current A 5,80 8,40 2,9 4,1 6,1
EER Btu/w 13,5 12,5 14 13 13
SEER Btu/w 22,5 21,5 22,8 21,5 20,8
Capacity Btu/h 9800 11800 9800 12000 18000
Power Input W 790 1120 930 1085 1570
Rated current A 6,90 9,80 4,20 4,72 6,82
COP W/W 3,6 3,1 3,1 3,2 3,4
HSPF Btu/w 10,5 11,2 10,5 9,8 10
Type ROTARY ROTARY ROTARY ROTARY ROTARY
Power Input W 748 800 748 800 1035
Dimension(W*D*H) in 31.57x7.44x11.69 31.57x7.44x11.69 31.57x7.44x11.69 31.57x7.44x11.69 42.52x8.90x13.19
Net/Gross weight lb 18.1/22.0 18.1/22.0 18.1/22.0 18.1/22.0 29.1/37.0
Dimension(W*D*H) in 30.31x11.81x21.85 31.50x13.11x21.81 30.31x11.81x21.85 31.50x13.11x21.81 33.27x14.29x27.64
Net/Gross weight lb 63.9/69.4 81.6/88.2 63.9/69.4 81.6/88.2 101.0/108.2
Liquid side/ Gas side in 1/4" / 3/8" 1/4" / 1/2" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2"
Max. difference in level ft 33 33 33 33 66
V-ph-Hz 115 / 1 / 60 115 / 1 / 60 208-230 / 1 / 60 208-230 / 1 / 60 208-230 / 1 / 60
A 15 20 15 15 20
cfm 294/212/147 306/212/147 265/205/141 306/212/147 559/365/306
dB(A) 37.5/-/23 36/32/23 39/-/24.5 39/-/25 45.5/-/34.5
cfm 1060 1120 1060 1120 1470
dB(A) 52,5 52,5 55,5 57,5 61
g R410A/1000g R410A1151g R410A/1000g R410A1151g R410A/1950g
oz R410A/38.8 R410A/40.6 R410A/38.8 R410A/40.6 R410A/68.8
ft 25 25 25 25 25
oz 0,161 0,161 0,161 0,161 0,161
psig 550/340 PSIG 550/340 PSIG 550/340 PSIG 550/340 PSIG 550/340 PSIG
AWG 16*4 Stranded, unshielded 16*4 Stranded, unshielded 16*4 Stranded, unshielded 16*4 Stranded, unshielded 16*4 Stranded, unshielded
ºF
ºF
sq.ft 350-400 450-550 350-400 450-550 700-1000
Remote Control Remote Control Remote Control Remote Control Remote Control
62~90/32~86
5~122/5~86
62~90/32~86
5~122/5~86
62~90/32~86
5~122/5~86
62~90/32~86
5~122/5~86
KSIE024-H220-I
KSIE024-H220-O
208-230 / 1 / 60
24000
1920
8,4
12,5
20,5
25000
2315
10,1
3,2
10
15
25
ROTARY
24344
1970
120(Output)
618/471/324
50/-/35.5
42.52x8.90x13.19
45.47x16.34x12.40
29.1/37.0
120(Output)
2355
61
40.55x16.54x31.89
42.91x19.69x34.06
136.69/147.27
R410A/2350g
R410A/82.9
25
0,322
550/340 PSIG
3/8" / 5/8"
164
82
16*4 Stranded, unshielded
Remote Control
62~90/32~86
5~122/5~86
900-1500
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without notice and without obligation on our part. Allways comply with local, state, and national electrical codes. 1 - Minimum 10 ft line set recommended. 2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
6 in
Mark of Superior Quality
D
H
W
H
W
D
Loading...