Klimaire KSIE012H120SW, KSIE024H220SW Instruction Manual

Page 1
SERIES
Ductless Split Comfort Systems
ADVANCED TECHNOLOGY
NEW RESIDENTIAL LINE
ENERGY SAVINGS ECO-FRIENDLY
Mark of Superior Quality
Page 2
What
brings
you …
SERIES
We have been in the Ductless Mini-Split business for over 25 years, Klimaire manufacturing maintains the highest standards of quality and reliability with ISO 9001 and ISO 14001a. Our products have proven their endurance and resiliency over time, operating in 70 different countries. All products are ETL certified and AHRI registered. Klimaire products exceed industry standards for energy efficiency and employ innovative technology to achieve the highest customer satisfaction. Since our goal is to achieve maximum customer satisfaction, we continuously seek to achieve higher performance levels in the design phase for all future units.
Ductless Mini-Split systems are one of the fastest growing products in the US and popularity is rapidly increasing. They allow air conditioning and heating systems to be added quickly, economically and conveniently, often for some applications where installing comfort systems didn't seem possible or practical.
Flexibility is the main driver of their popularity. Klimaire ductless systems are simple, reliable, easy to install, and extremely affordable. Klimaire slim single zone and multi zone ductless systems offer built-in solutions with duct free technology benefits. These systems are integrated with innovative inverter technology providing individual comfort and control. With our KSIE series we are committed to bring our valued customers additional savings with a unit almost ready to install, easily and quickly, with minimum HVAC technician assistance.
How much
do you spend
heating
for
& cooling
your home?
The US Department of Energy (DOE) says that as much as half of the energy used in your home goes to heating and cooling. So making smart decisions about your home's heating, ventilating, and air conditioning (HVAC) system can have a big effect on your utility bills and your comfort.
8% Other* 2% Dishwasher
49%
Heating & Cooling
Klimaire Invertech DC Inverter - driven ductless air conditioners and heat pumps can save you up
to 33% on your power utility bill when compared with room air conditioners or standard efficiency
ductless systems. Ductless Invertech units are practical to install and preferred over traditional
ducted central units.
Total savings can reach up to 49% when heat pump technology is combined with an inverter
system.
5% Refrigerator
Clothes Washer
& Dryer
6%
7% Electronics
10% Lighting
13% Water Heating
Mark of Superior Quality
2
Page 3
What is
Klimaire
DC Inverter?
SERIES
Klimaire DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called “DC inverter” because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. As known, the current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result different running speeds of the compressor. Klimaire Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter air conditioners bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Contioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically. Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. By this way it will maintain a constant temperature.
Room Temp.
Fixed Speed AC
DC Inverter AC
Too Hot
Set
Temp.
T2
T1
Comfortable
Too Cold
Time
The higher the efficiency, the higher your savings
You´ll save energy everytime you use a Klimaire Ductless System. Air ducts from a central forced air system can lose energy, with air leakage specially if the ducts run through unconditioned areas like attics or basements. Since Klimair Ductless Systems have no ducts, they avoid that energy loss completely, reducing your impact on the environment and lowering your energy costs. System efficiency is measured in SEER, with stands for Seasonal Energy Efficiency Ratio. Similar to miles per gallon in a car, SEER measures te overall efficiency of a heating and cooling system on a seasonal basis. The higher the SEER, the greater the system´s energy efficiency. With SEER ratings for Klimaire Ductless Indoor Units ranging from 14 to 24.4, our ductless systems are remarkably efficient and environmentally friendly.
Annual savings for cooling your home based on the efficiency of a matched system
Minimum efficiency established by the Department of Energy, Potenial energy savings may vary depending on your personal lifestyle, system settings and usage, equipment maintenance, local climate, actual construction and installation of equipment and duct system.
7 %
0 %
13 SEER 14 SEER 15 SEER 16 SEER 18SEER 20 SEER 22 SEER
13 %
19 %
35 %
28 %
41 %
47 %
24.4 SEER
Mark of Superior Quality
3
Page 4
Experience true individual comfort. Ductless Mini-Split systems are the perfect solution to a variety of installation challenges. Ductless Mini-Split units eliminate the use of ductwork, allowing installers the ability to place these units in locations that were previously considered impractical or impossible due to additional ducting and cost associated with installing a regular unit. Ductless Mini-Splits consist of two parts, an outdoor unit and an indoor unit, similar to regular split units, but much smaller in size. The outdoor and indoor units are connected to each other by refrigerant and electrical lines. They run together with a condensate drain line through a small hole in an exterior wall, generally 3 inch in diameter or less. In addition to eliminating the need for ducting, another great advantage of Ductless Mini-Split systems is true zone control. The indoor fan coil unit is dedicated to the room being conditioned, allowing a temperature and humidity level to be kept in a specific room, separate from the rest of the house or building.
SERIES
Ductless Mini-split
Personalized Comfort Solution
Accessories
115 - 230 V
Condensate Drain
Mini-Pumps
Interactive
When I show these codes on the display, that means ...
DF
CL
ü I’m defrosting.
ü I’m dirty, please clean my filters up.
display
WAFB21
Outdoor unit wall brackets
WAFP21
EZ - Quick installation kits
16, 25, 35, 50 ft.
When you press any function button
Turbo
ü That means you switch “Turbo
ON
Mode” on
AQS-0066-11
Aqua Over-Flow Switch
NF
Mark of Superior Quality
ü My filters are too old, please change new
ones for me.
OF
ü That means you switch “Turbo
Mode” off
4
Page 5
Easy Maintenance
Easy Maintenance
SERIES
Self-Diagnosis & auto Protection
Universal PCB design
For 115v one after-service PCB For 230v one after-service PCB
Easy Access
• Louvers structure special design, easy to disassemble
•P ush the button slightly, easy to clean.
Leakage Detection
* Refrigerant Leakage Detection
* You will be alerted when refrigerant is low.
* Preventes damage to the compressor
* Automatically turns off the unit
Service Friendly
* Emergency Function Using
Manual Switch Button
Easy to turn on/off without a tool.
ü
Emergency Using Function
Smartly detecting errors, your unit
ü
keep running when in urgent need
Old Design
.
New Design
Easy Installation
Thicker and wider plate makes the installation solid and safe.
Easy to mount & connect
Installation gap for
4 INCH
pipe connection > 4 in. It is easier to connect the pipes.
LEFT
REAR
RIGHT
Multi-refrigerant outlet pipe method: left/right/rear, more flexible for installation.
Mark of Superior Quality
5
Page 6
SERIES
Super
Quiet
Low Noise Design Optimize air discharge vane
Silent Mode
Every year you will save 26% money
Power Input
Example: Unit of 12000Btu/h (cooling capacity)
Fixed Speed Inverter
SEER
Cooling cost
Heating costs
Total
• According to AHRI , refer https:// www.ahridirectory.org for detail
M ax
Decrease
3.5dB(A )
Indoor fan run at an extra breeze
Fixed Speed AC
DC Inverter AC
13 21
$114 $73
$258 $202
$372 $275
Save
26%
Time
Self
Cleaning
Your Klimaire KSIE series equiped with Auto Clean Function cleans. and dry the evaporator to prevent mist dew grove and keep it fresh for next operation
Mark of Superior Quality
Indoor Air Quality
Your Klimaire KSIE series equiped with Auto Clean Function. It cleans and dries the evaporator to prevent mildew grow and keep it fresh for next operation.
Operation
Time
(minute)
Low Fan
Only
1-13
Heating
& Low Fan
14
Low Fan
Only
15-16
6
Page 7
SERIES
Wi-Fi Capability (Optional)
Control Your Klimaire Mini-Split From Anywhere
How does it work?
®
iOS or Android APP
The mini-splits are controlled from a webpage or using an iOS or Android APP in a very intuive way.
Wi Fi Control Features
Optional Smart Kit
To have remote access to control your Klimaire unit, oponal smart kit should be installed.
Temperature Home
Monitor current room temperature, set mer on/off acvate frost protecon and sleep mer.
Save Money
Save money without losing comfort.
Smart Kit (Wi-Fi)
An oponal Smart Kit (Wi-Fi) device installed in each unit controls the operaon.
Turn on/off mini-split
Turn your A/C on/off as you wish
Check AC
Check AC running status and display detailed informaon
Cloud Managed
A Server in the cloud manages the whole process.
Change Program Settings
Change the program sengs, such fan speed, temperature, and operaon mode
Program Calendar
Program the mini-split with a calendar scheduler in an easy, intuive way.
Remotely managed
Remotely manage your mini-split system using a simple smartphone, tablet or PC via the Internet.
Your Klimaire Wi-Fi enabled air condioner lets you control your ductless mini split air condioner using your smartphone or tablet from anywhere internet connecon is available. Our free IOS and Android smartphone app gives you the freedom to instantly adjust your sengs saving you me and money on energy consumpon and cost.
iOS and
Android APPS
From Everywhere
Using any
Web Browser
Optional Smart Kit
Cloud System
Local Control
Standard Wi-Fi
b/g/n router
75°
COOL
78 %18:30
F
7
Page 8
SERIES
Service
Friendly
Remote
Control
* Emergency Function Using
Manual Switch Button
Easy to turn on/off without a tool.
ü
Emergency Using Function
Smartly detecting errors, your unit
ü
keep running when in urgent need
I - Remote Control Parameter change
.
ü Set your preferred settings
Function Adjustment
1 Auto Restart Function Active / Shut off
2 Temp. Compensation Set value from 0? to 6?
3 Lock Function Lock / Unlock
4 Anti- cold Air Function
Indoor Fan Speed When Set
5
Temp. is Achieved
Intelligent mode/ Common mode
Indoor fan stop / Indoor fan speed down / Indoor fan speed remain
Old Design
Ordinary
.
New Design
KSIE SERIES
Multiple
Control
Options
2 control ways are optional.
Leakage
Detection
Easy
Installation
11 Lowest set point From 62F to 76 F
12 Highest set point From 78F to 88F
* Refrigerant Leakage Detection
* You will be alerted when refrigerant es low.
* Preventes damage to the compressor
* Automatically turns off the unit
Installation gap for
4 INCH
pipe connection > 4 in. Normally about 3 in. It is more easy to connect the pipe.
2 INCH
Remote Control
Wired Control (optional)
ü Avoid mislaying
Installation position from right to left, more than 2 in. Installer do not need to finding the mounted plate.
Mark of Superior Quality
Multi-refrigerant outlet pipe method: left/right/rear, more flexible for installation.
LEFT
REAR
RIGHT
8
Page 9
1
ON/OFF Button
This button turns the air conditioner ON and OFF.
2
MODE Button Press this button to modify the air conditioner mode in a sequence of following:
AUTO
NOTE: Please do not select HEAT mode if the machine you purchased is cooling only type. Heat mode is not supported by the cooling only appliance.
3
FAN Button Used to select the fan speed in four steps:
AUTO LOW MED HIGH
NOTE: You can not switch the fan speed in AUTO or DRY mode.
COOL
DRY
HEAT
FAN
SERIES
Remote
Control
8
SILENCE/FP Button
Active/Disable SILENCE function. If pushing more than 2 seconds, the “FP” function will be activated, pushing more than 2 seconds again to disable.
When the Silence function is activated, the compressor will operate at low frequency
AUTO
FAN
AUTO
7
1
ON/OFF
SILENCE
FP
8
and the indoor unit will bring faint breeze, which will reduce the noise to the lowest level and creat a quiet and comfortable room for you. Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity.
Activates/Disables freeze protection”FP” or HOME-AWAY function. It can only be activated during the heating operation. (only when the setting mode is HEAT). The unit will operate at high fan speed with the temperature automatically set to 46 F. The display window of indoor unit will display FP. For the unit without display area, the Defrost indicator light will be keeping on for 2 seconds Keeps the room over freezing temperature.
4
SLEEP Button
Active/Disable sleep function. It can maintain the most comfortable temperature and save energy. This function is available on COOL, HEAT or AUTO mode only .
For the detail, see “sleep operation” in “USER´S MANUAL”.
NOTE: While the unit is running under SLEEP mode, it would be cancelled if MODE, F SPEED or ON/OFF button is pressed.
5
TURBO Button Active/Disable Turbo function. Turbo function enables the unit to reach the preset temper­ature at cooling or heating operation in the shortest time (if the indoor unit does not support this function, there is no corresponding operation happened when pressing this button.)
6
SELF CLEAN Button Active/Disable Self Clean function. Under SELF CLEAN mode, the air conditioner will automatically clean and dry the Evaporator and keep it as fresh for the next operation.
7
UP Button ( ) Push this button to increase the indoor temperature setting in 1F increments to 86ºF.
DOWN Button ( ) Push this button to decrease the indoor temperature setting in 1F increments to 62ºF.
NOTE: Temperature contol is not available in Fan mode.
NOTE: Press and hold UP and DOWN buttons together for 3 seconds will alternate the temper­ature display between the ºC & ºF scale.
o
o
AN
2
3
4
MODE
TEMP
FAN
SLEEP
TIMER
ON
TIMER
OFF
SWING DIRECT
9
10
11
9
TIMER ON Button Press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 30 minutes increments. When the setting time displays
10.0, each press will increase the auto­timed setting 60 minutes increments. To cancel the auto-timed program, simply adjust the auto-on time to 0.0.
12
SELF
TURBO
5
CLEAN
6
LED
FOLLOW
ME
13
14
10
TIMER OFF Button
Press this button to initiate the auto-off time sequence. Each press will increase the auto
-timed setting in 30 minutes increments. When the setting time displays 10.0, each press will increase the auto-timed setting 60 minutes increments. To cancel the auto­timed program, simply adjust the auto-off time to 0.0
11
SWING Button
Used to stop or start horizontal louver auto swing feature.
12
DIRECT Button
Used to change the louver movement and set the desired up/down air flow direction. The louver changes 6 in angle for each press.
13
FOLLOW ME Button
Push this button to initiate the Follow Me feature, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. The air conditioner will cancel the Follow Me feature automatically if it does not receive the signal during any 7 minutes interval.
14
LED Button
Disable/Active indoor screen Display. When pushing the button, the indoor screen display is cleared, press it again to light the display.
O
Mark of Superior Quality
9
Page 10
Standard
AUTO
AUTO
FAN
ON/OFF
SHORT CUT
TIME
ON
TIME OFF
MODE
TEMP
Features
SERIES
Auto Restart
Function
Self-diagnosis and
Auto-protection
Anti-cold Air Function Louver Position
Two-directional
Airflow
12 Grades Indoor
Fan Speeds
Auto Defrosting
Memory Function
Timer High Density Filter
Turbo Mode
Emergency Using
Function
Manual Switch Button Fire-proof
Sel Clean Operation
Refrigerant
Leakage Detect
Electric Box
Except for 9K
**
24k non-estar models.
Follow Me
Low Ambient Cooling
Auto Swing
-
Reliability
KSIE
Product
Code
Base Pan Heater
Prevents defrost condensation
from freazing ensuring proper defrost
drainage during heating season
S I EK 012 H 2 20 O
Brand K: Klimaire
Model S: System
Unit Type I : Inverter
Compressor Heater
Ensures Compressor
longevity and reliability
Nominal Capacity
09: 9,000 Btu/h 12: 12,000 Btu/h 18: 18,000 Btu/h 24: 24,000 Btu/h
Product Series
A high performance double cam twin rotary compressor increases the performance, reliability and durability
-
Power Supply 1 : 115/60 2 : 208-230/1/60
Operational Information H: Heat Pump
TwinCam
Efficiency
Unit Type O: Outdoor
I: Indoor
SEER
Mark of Superior Quality
10
Page 11
SERIES
20-23 SEER
Klimaire Model Number - Indoor KSIE009-H121-I KSIE012-H120-I KSIE009-H221-I KSIE012-H220-I KSIE018-H220-I
Klimaire Model Number - Outdoor KSIE009-H121-O KSIE012-H120-O KSIE009-H221-O KSIE012-H220-O KSIE018-H220-O
Power supply
Cooling
Heating
Minimum Circuit ampacity A 15 15 15 15 15
Maximum Fuse Size
Compressor Capacity Btu/h 10014 11157 10014 11157 13836
Indoo fan motor Power Input W 20(Output) 20(Output) 20(Output) 20(Output) 58(Output)
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Indoor unit Packing (W*D*H) in 34.45x11.22x14.76 34.45x11.22x14.76 34.45x11.22x14.76 34.45x11.22x14.76 45.47x16.34x12.40
Outdoor fan motor Power Input W 40(Output) 40(Output) 40(Output) 40(Output) 50(Output)
Outdoor air flow
Outdoor noise level
Outdoor unit Packing (W*D*H) in 35.43x13.58x23.03 36.22x15.35x24.21 35.43x13.58x23.03 36.22x15.35x24.21 38.00x15.55x29.72
Refrigerant type
Refrigerant type / charge
Refrigerant precharge for up to
Additional charge per each ft
Design pressure
Refrigerant piping Max. refrigerant pipe length ft 82 82 82 82 98
Connection wiring
Thermostat type
Operation Indoor(cooling/ heating) 62~90/32~86
Temperature Outdoor(cooling/heating)-optional 5~122/5~86
Application area (cooling standard)
Capacity Btu/h 9000 12000 9000 12000 18000
Power Input W 665 960 640 923 1384
Rated current A 5,80 8,40 2,9 4,1 6,1
EER Btu/w 13,5 12,5 14 13 13
SEER Btu/w 22,5 21,5 22,8 21,5 20,8
Capacity Btu/h 9800 11800 9800 12000 18000
Power Input W 790 1120 930 1085 1570
Rated current A 6,90 9,80 4,20 4,72 6,82
COP W/W 3,6 3,1 3,1 3,2 3,4
HSPF Btu/w 10,5 11,2 10,5 9,8 10
Type ROTARY ROTARY ROTARY ROTARY ROTARY
Power Input W 748 800 748 800 1035
Dimension(W*D*H) in 31.57x7.44x11.69 31.57x7.44x11.69 31.57x7.44x11.69 31.57x7.44x11.69 42.52x8.90x13.19
Net/Gross weight lb 18.1/22.0 18.1/22.0 18.1/22.0 18.1/22.0 29.1/37.0
Dimension(W*D*H) in 30.31x11.81x21.85 31.50x13.11x21.81 30.31x11.81x21.85 31.50x13.11x21.81 33.27x14.29x27.64
Net/Gross weight lb 63.9/69.4 81.6/88.2 63.9/69.4 81.6/88.2 101.0/108.2
Liquid side/ Gas side in 1/4" / 3/8" 1/4" / 1/2" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2"
Max. difference in level ft 33 33 33 33 66
V-ph-Hz 115 / 1 / 60 115 / 1 / 60 208-230 / 1 / 60 208-230 / 1 / 60 208-230 / 1 / 60
A 15 20 15 15 20
cfm 294/212/147 306/212/147 265/205/141 306/212/147 559/365/306
dB(A) 37.5/-/23 36/32/23 39/-/24.5 39/-/25 45.5/-/34.5
cfm 1060 1120 1060 1120 1470
dB(A) 52,5 52,5 55,5 57,5 61
g R410A/1000g R410A1151g R410A/1000g R410A1151g R410A/1950g
oz R410A/38.8 R410A/40.6 R410A/38.8 R410A/40.6 R410A/68.8
ft 25 25 25 25 25
oz 0,161 0,161 0,161 0,161 0,161
psig 550/340 PSIG 550/340 PSIG 550/340 PSIG 550/340 PSIG 550/340 PSIG
AWG 16*4 Stranded, unshielded 16*4 Stranded, unshielded 16*4 Stranded, unshielded 16*4 Stranded, unshielded 16*4 Stranded, unshielded
ºF ºF
sq.ft 350-400 450-550 350-400 450-550 700-1000
Remote Control Remote Control Remote Control Remote Control Remote Control
62~90/32~86
5~122/5~86
62~90/32~86
5~122/5~86
62~90/32~86
5~122/5~86
62~90/32~86
5~122/5~86
KSIE024-H220-I
KSIE024-H220-O
208-230 / 1 / 60
24000
1920
8,4
12,5
20,5
25000
2315
10,1
3,2
10
15
25
ROTARY
24344
1970
120(Output)
618/471/324
50/-/35.5
42.52x8.90x13.19
45.47x16.34x12.40
29.1/37.0
120(Output)
2355
61
40.55x16.54x31.89
42.91x19.69x34.06
136.69/147.27
R410A/2350g
R410A/82.9
25
0,322
550/340 PSIG
3/8" / 5/8"
164
82
16*4 Stranded, unshielded
Remote Control
62~90/32~86
5~122/5~86
900-1500
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without notice and without obligation on our part. Allways comply with local, state, and national electrical codes. 1 - Minimum 10 ft line set recommended. 2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
6 in
Mark of Superior Quality
D
H
W
H
W
D
11
Page 12
Eco Friendly
SERIES
Note: The data in this brochure may be changed without notice for further improvement on quality and performance
2190 NW 89th Place Doral, FL 33172 - USA e-mail: sales @klimaire.com www.klimaire.com
Mark of Superior Quality
Loading...