Klimaire KSIA024H216S Specifications

16 SEER
Klimaire Model Number KSIA009-H216 KSIA012-H216 KSIA018-H216 KSIA024-H216
Cooling Rated Current A 3,68 5,94 8,96 10,76
Heang Power Input kW 0,941 1,16 1,715 2,207
Minimum Circuit Ampacity A 7,2 7,9 6,5 11 Max Overload Protecon Breaker A 15 15 15 15 Dehumidificaon pint/h 1,69 2,5 3,17 4,64
Compressor Power Input W 735 825 1255(4000 rpm) 1141
Outdoor Fan Motor RLA A 0,31 0,31 0,51 0,7
Outdoor Air Flow cfm 1089 1089 1400 1530 Outdoor Noise Level dB(A) 50 50 53 54
Indoor Fan Motor RLA A 0,21 0,21 0,425 0,44
Indoor Air Flow cfm 540 560 840 1150 Indoor Noise Level (L-M-H) dB(A) 30 - 32 - 37 35 - 39 - 43 37 - 41 - 45 40 - 42 - 47
Max Refrigeraon Pipe Length 49,2 49,2 98,4 98,4
Max Elevaon Difference Refrigerant Type R-410A R-410A R-410A R-410A Refrigerant Charge (up to 25 line set) oz 27,51 34,22 56,44 65,26
Refrigerant Pipe Size
Drain Hose Connecon OD in 1/2 1/2 1/2 1/2 Design Pressure psig 550 / 340 550 / 340 550 / 340 550 / 340 Connecon Method Type Flare Flare Flare Flare
Connecng Wiring AWG
Operaon temperature
Indoor Unit
Outdoor Unit
Cerficaons ETL/cETL/ AHRI Performance Cerfied 210/240 Applicaon Area sq. . 350-400 450-550 700-1000 900-1500
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without notice and without obligation on our part.
Allways comply with local, state, and national electrical codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m)
Capacity Btu/h 9000 12000 18000 23200 Inverter Capacity Range Btu/h 3753~10918 4094~13306 5118~19107 6142~23884 Power Input kW 0,84 1,36 2,05 2,465
Indoor Air Flow Volume cfm 540 560 840 1150 SEER 16,3 16 16,4 16 EER 9.6 9.9 9.4 8.6 Capacity Btu/h 10000 12000 18000 23200 Inverter Capacity Range Btu/h 4435~11942 4094~13648 5118~19107 6142~23884
Rated Current A 5,34 6,54 7,49 9,63 HSPF 8,4 8,2 8,4 8,2 COP 11,26 10,58 10,75 10,58
Type Rotary Rotary Twin-rotary Twin-rotary
Rated current (RLA) A 5,25 5,8 4,2 7,95 Locked Rotor Amp (LRA) A 20 20 20 20 Power Input W 36 36 60 78
Speed (Hi/Mi/Lo) rpm 770/550/500 850/550/450 900/700/600 800/600/500
Power Input W 41 41 80 88
Speed (Hi/Mi/Lo) rpm 1130/1000/850 1130/100/850 1080/970/850 1080/970/850
2
Liquid in 1/4 1/4 1/4 1/4 Gas in 3/8 1/2 1/2 5/8
Indoor (Cooling/Heang) ºF 60.8 – 89.6/ 60.8 – 89.6 60.8 – 89.6/ 60.8 – 89.6 60.8 – 89.6/ 60.8 – 89.6 60.8 – 89.6/ 60.8 – 89.6 Outdoor (Cooling / Heang) ºF 50– 125.6/5-104 50– 125.6/5-104 50– 125.6/5-104 50– 125.6/5-104 Unit Dimensions (W x H x D) in 29.5 x 11.2 x7.9 29.5 x 11.2 x7.9 35.4 x 12.2 x 8.9 42.6 x 13 x 9.2
Packing Dimensions (W x H x D) in 32.3 x 13.6 x 11 32.3 x 13.6 x 11 38.2 x 15 x 12 45.5 x 15.6 x 12.4
Net / Gross Weight lb 17.6 / 22 18.7 / 23.1 26.5 / 32 35.3 / 41.9
Unit Dimensions (W x H x D) in 28.3 x 21.3 x10.2 28.3 x 21.3 x10.2 31.6 x 21.1 x 11.7 31.5 x 27.2 x11.8
Packing Dimensions (W x H x D) in 33.5 x 24.4 x 14.6 33.5 x 24.4 x 14.6 36.2 x 24.4 x 15.8 37x 29.5 x 16.5
Net/Gross Weight lb 59.5 / 68.3 60.6 / 69.4 88.2 / 97 110.3 / 121.3
16,4 16,4 23 33
4*18 AWG 4*18 AWG 4*18 AWG 4*18 AWG
SERIES
6 in
D
W
11
H
H
W
D