Klimaire KMIR545H219 Specifications

C US
KMIR - Technical Specifications
KMIR Series Outdoor Units
Klimaire Multi Zone Outdoor Unit Model Number KMIR218-H221 KMIR327-H217 KMIR436-H222 KMIR545-H219
Power supply V-ph-Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Capacity Btu/h 17000 27000 36000 48000
Cooling EER Btu 12,5 12,0 10,9 11,6
SEER
Capacity Btu/h 18000 28000 36000 48000
Heating @ 47ºF
Heating @ 17ºF Btu/h 11800 16800 25400 30800
Heating @ 5ºF Btu/h 14200 20900 28800 35800
Minimum Circuit Ampacity
Max. Fuse Size
Compressor Power Input W 1170 1970 2600 3040
Outdoor RLA A 0,74 0,9 1,3 0,39
Fan motor
Outdoor air flow cfm 1390 2130 2130 4500
Outdoor noise level dB(A) 62,4 63,4 62,3 64
Outdoor unit Packing (W*D*H) in 37.99x15.55x29.72 42.91x19.69x34.45 42.91x19.69x34.45 43.11x19.49x58.27
Refrigerant type oz R410A / 70.5 R410A / 98.8 R410A / 105.8 R410A / 162.3
Refrigerant precharge (Total pipe length) ft 25 25 25 25
Additional charge for each ft oz 0,161 0,161 0,161 0,32
Design pressure psig 550/340 550/340 550/340 550/340
Refrigerant piping Max. length for one indoor unit ft 66 82 98 98
Connection wiring No No No No
Ambient temperature Cooling -13~122 -13~122 -13~122 -13~122
Rated capacity
Maximum capactiy
A 18 25 30 35
A 25 35 45 50
Type Rotary Rotary Rotary Twin-Rotary
Capacity Btu/h 15388 24345 32380 38214
Rated current (RLA) A 10 20,00 22,00 21,00
Refrigerant oil / Oil charge pint VG74 / 1.06 POE(VG74) / 1.42 PQE(VG74) / 2.1 Ester Oil VG74 / 2.96
Power Input W 115 150 150 126
Speed rpm
Dimension(W*D*H) in 33.27x14.29x27.64 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48
Net/Gross weight lb 105.82/114.64 149.91/160.94 156.53/167.55 223.77/255.07
Liquid side / Gas side in 2 x (1/4"/3/8") 3 x (1/4"/3/8") 4x1/4" / (3x3/8"+1x1/2") 5x1/4" / 3x3/8" + 2x1/2"
Max. length for all rooms ft 98 148 197 246
Max. height difference OU lower than IU ft 49 49 49 49
Max. height difference between I.U.s ft 33 33 33 33
Heating -13~86 -13~86 -13~86 -13~86
OU higher than IU ft 49 49 49 49
150/200/250/300/350/450/
21.3
3,7 3,7 3,1 3,4
150/200/250/300/400/500/
550/650/800/850
22,0 22,5 21,5
600/750/900/1000
150/200/250/300/400/500/
600/750/900/1000
150/200/250/300/400/500/
600/700/800/870
5 Zones
H
2 - 3 - 4 Zones
H
W
Connued product improvement is our goal at Klimaire Products, Inc. Hence, specificaons and data listed herein are subject to change without noce and without obligaon on our part. Allways comply with local, state, and naonal electrical codes. 1 - Minimum 10  line set recommended. 2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17  to 23  ( 5 to 7 m) 3 - Factory installed only, not field opon. Units may operate in heang and cooling mode unl the ambient condions reach 5º F