Klimaire KM14B1041 Instruction Manual

Page 1
SERIES
Ductless Split Comfort Systems
NEW COMMERCIAL LINE
ADVANCED TECHNOLOGY ENERGY SAVINGS ECO-FRIENDLY QUICK & EASY INSTALLATION
Mark of Superior Quality
Page 2
SERIES
We have been in the Ductless Mini-Split business for over 25 years, Klimaire manufacturing maintains the
What Klimaire brings you …
Ductless Mini-Split systems are one of the fastest growing products in the US and popularity is rapidly increasing. They allow air conditioning and heating systems to be added quickly, economically and conveniently, often for some applications where installing comfort systems didn't seem possible or practical.
Flexibility is the main driver of their popularity. Klimaire ductless systems are simple, reliable, easy to install, and extremely affordable. Klimaire slim single zone and multi zone ductless systems offer built-in solutions with duct free technology benefits. These systems are integrated with innovative inverter technology providing individual comfort and control. With our KSIX series we are committed to bring our valued customers additional savings with a unit almost ready to install, easily and quickly, with minimum HVAC technician assistance.
highest standards of quality and reliability with ISO 9001 and ISO 14001a. Our products have proven their endurance and resiliency over time, operating in 70 different countries. All products are ETL certified and AHRI registered. Klimaire products exceed industry standards for energy efficiency and employ innovative technology to achieve the highest customer satisfaction. Since our goal is to achieve maximum customer satisfaction, we continuously seek to achieve higher performance levels in the design phase for all future units.
How much do you spend for heating & cooling your home?
The US Department of Energy (DOE) says that as much as half of the energy used in your home goes to heating and cooling. So making smart decisions about your home's heating, ventilating, and air conditioning (HVAC) system can have a big effect on your utility
Klimaire Invertech DC Inverter - driven ductless air conditioners and heat pumps can save you up to 33% on your power utility bill when compared with room air conditioners or standard efficiency 10 SEER ductless systems. Ductless Invertech units are practical to install and preferred over traditional ducted central units. Total savings can reach up to 49% when heat pump technology is combined with an inverter system.
49%
Heating & Cooling
8% Other* 2% Dishwasher
5% Refrigerator
10% Lighting
13% Water Heating
Clothes Washer
& Dryer
6%
7% Electronics
What is Klimaire DC Inverter?
Klimaire DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called “DC inverter” because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. As known, the current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result different running speeds of the compressor. Klimaire Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter air conditioners bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Contioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically. Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of
the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. By this way it will maintain a constant temperature.
Set
Temp.
Room Temp.
T2
T1
Fixed Speed AC
DC Inverter AC
Too Hot
Comfortable
Too Cold
Time
Ducted vs Ductless Systems
According To the US Department of Energy (energy.gov) “Since mini splits have no ducts ,they avoid the energy losses associated with ductwork of central forced air systems. Duct losses can account for more than 30% of energy consumption for space conditioning especially if the ducts are in an unconditioned space such as attic.”
You´ll save energy every time you use a Klimaire Ductless System. Air ducts from a central forced air system can lose energy more than 30%, with air leakage especially if the ducts run through unconditioned areas like attics or basements. Since Klimaire Ductless Systems have no ducts, they avoid that energy loss completely, reducing your impact on the environment and lowering your energy costs. Only one temperature control for all the zones, conflicting with individual comfort preferences
Mark of Superior Quality
Page 3
Supply air Temperature at grille outlet is aprox. 5°F less than in unit outlet.
Ductwork in the attic space
SERIES
Ducted Systems Vs Ductless Systems
Unconditioned attic space Summer temperature reach up to 125° F Winter temperatuers reach down to 25° F
Duct losses can reach up to 30% due to leakage & temperature differences between grilles and the unit outlet
Colder air in duct gets less cold reaching to grille outlets
ATTIC CONDITION IN SUMMER SEASON
Typical Single Family Summer Condition
HOT A
T
TIC SPACE
56° Leaving Temp.
Return Air 75°F
60°F Supply Temp.
Summary: Duct Losses Can Be Over 30%
Ductless Mini-split
Experience true individual comfort. Ductless Mini-Split systems are the perfect solution to a variety of installation challenges. Ductless Mini-Split units eliminate the use of ductwork, allowing installers the ability to place these units in locations that were previously considered impractical or impossible due to additional ducting and cost associated with installing a regular unit. Ductless Mini-Splits consist of two parts, an outdoor unit and an indoor unit, similar to regular split units, but much smaller in size. The outdoor and indoor units are connected to each other by refrigerant and electrical lines. They run together with a condensate drain line through a small hole in an exterior wall, generally 3 inch in diameter or less. In addition to eliminating the need for ducting, another great advantage of Ductless Mini-Split systems is true zone control. The indoor fan coil unit is dedicated to the room being conditioned, allowing a temperature and humidity level to be kept in a specific room, separate from the rest of the house or building.
Personalized Comfort Solution
OUTDOOR UNIT
Indoor Unit / Evaporator
COLD A
T
TIC SPACE
Return Air 70°F
OUTDOOR UNIT
Conduit for Refrigerant Lines & Wiring
Temperature leaving the A.H.U.
AIR HANDLING UNIT (AHU)
ATTIC CONDITION
IN WINTER SEASON
Typical Single Family
85°F Supply Temp.
OUTDOOR UNIT
Wall mounted outdoor unit
Outdoor Unit / Condenser
Winter Condition
40° Leaving Temp.
Page 4
Total Comfort
SERIES
Auto swing air swipe
Oscilating Louver Technology distribute air evenly throughout the room with horizontal auto swing function
Long range air discharge
Powerful and silent air flow thru larger fan diameter to reach every spot of the room
New Design
KSIR fan diameter increased, air blow distance farther, air flow volume bigger
3 fan speeds
2
1
Turbo mode
Quiet & Efficient
Low Noise Design Optimize air discharge vane
Silent Mode
3
M ax
Decrease
3. 5dB(A )
Indoor fan run at an extra breeze
Allow you to adjust the airflow precisely to the setting that gives you the greatest comfort
Turbo function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time
Independient Humidity Control
Unique Comfort in Cooling & Heating
Room temperature 77ºF Humidity 50% COMFORTABLE Decreasing humiditywhile maintaining the temperature increases comfort
Room temperature 77ºF Humidity 80% UNCOMFORTABLE Hot and stuffy with high humidity
Since humidity is a major factor for comfort, Klimaire DC INVERTER adjusts to summer and winter
months – driven variable speed compressors reduces capacity to match lighter loads, increasing
the run time to remove moisture and reduce relative humidity resulting in improved comfort. In the
winter, by increasing the speed of the compressor,
Klimaire air conditioner and heat pump systems
are able to maintain capacity and deliver warmer
supply air even at low outdoor ambient conditions
as low as 5°F
Convenience
ON/OFF 24 hr. Programmable Timer
Louver Position Memory Function
When you start the unit, the horizontal louver will return automatically to the same position that was set last time
Timer can be set ON/OFF easily upto 24 hours using the wireless remote control (Set time: 0.5, 1, 1.5, 2, 2.5,...)
9 PM
Set
10 hr.
Set your confort
OFF 3 hr.
12
7
6
ON
preferences
-
Dry mode function in remote
Remote Control
39
TIMER
OFF
11 hr.
During DayDuring Night
Set your confort
preferences
+
12
39
7
6
ON
Page 5
SERIES
EASY MAINTENANCE
Micro –Processor Control
Self Diagnostic function monitors and displays working conditions and provides auto protection.
Service Friendly
* Emergency Function Using
Manual Switch Button
• Easy to turn on/off without a tool.
ü
Emergency Using Function
• Smartly detecting errors, your unit
ü
keep running when in urgent need
Old Design
.
New Design
PRODUCT HIGHLIGHTS
Klimaire Invertech DC inverter -driven air conditioners and heat pumps are among the most ultimate in cooling and heating technology available in HVAC. Energy savings are much higher with this INVERTECH DC INVERTER - driven variable speed compressor.
Thin & Slim design
Thin and slim design is realized by multi-bend high efficient hydrophilic fin heat exchanger and high efficiency blower wheel.
MULTI-BEND
HYDROPHILIC
HEAT EXCHANGER
Low ambient heating & cooling
* KSIF series have the ability to produce heat in ambient conditions down to 5° F * KSIF series operates in cooling mode in the low winter ambient conditions donw to 5° F when heating is necessary in spaces like server rooms, sun rooms & hydroponic nurseries.
The outdoor unit is engineered with specialized sensors and dual heater technology such as base pan and crankcase heaters enabling it to operate in harsh conditions as low as 5° F
Homeowners and neighbors enjoy the quiet whisper of the outdoor units operation, less noise to the surroundings keeps the environment peaceful.
Leakage Detection
* You will be alerted when refrigerant is low. * Preventes damage to the compressor * Automatically turns off the unit
LARGE AIR INTAKE
HIGH EFFICIENCY BLOWER WHEEL
°F
104
86
68
50
32
10
-4
122
COOLING
°F
°F
86
HEATING
°F
15
°F
5
11.1 in
Self Cleaning
Self Cleaning
Your Klimaire KSIE series equiped with Auto Clean Function. It cleans and dries the evaporator to prevent mildew grow and keep it fresh for next operation.
Interactive display
When I show these codes on the display, that means ...
ü I’m defrosting.
DF
ü I’m dirty, please
CL
clean my filters up
ü That means you switch
ON
OF
“Turbo Mode” on
.
ü That means you switch
“Turbo Mode” off
When you press any function button
ü My filters are too old, please
NF
change new ones for me.
Turbo
Indoor Air Quality (IAQ) Options
BIO FILTER COMPOUND FILTER SILVER ION FILTER HIGH DENSITY FILTER CARBON FILTER
Operation
Time
(minute)
Low Fan
Only
1-13
Heating
& Low Fan
14
c
CATECHIN FILTER VITAMIN C FILTER
Low Fan
Only
15-16
5
Page 6
SERIES
1
ON/OFF Button
This button turns the air conditioner ON and OFF.
2
MODE Button Press this button to modify the air conditioner mode in a sequence of following:
AUTO
NOTE: Please do not select HEAT mode if the machine you purchased is cooling only type. Heat mode is not supported by the cooling only appliance.
3
FAN Button Used to select the fan speed in four steps:
AUTO LOW MED HIGH
NOTE: You can not switch the fan speed in AUTO or DRY mode.
4
SLEEP Button
For the detail, see “sleep operation” in “USER´S MANUAL”.
5
6
7
COOL
Active/Disable sleep function. It can maintain the most comfortable temperature and save energy. This function is available on COOL, HEAT or AUTO mode only .
NOTE: While the unit is running under SLEEP mode, it would be cancelled if MODE, F SPEED or ON/OFF button is pressed.
TURBO Button Active/Disable Turbo function. Turbo function enables the unit to reach the preset temper­ature at cooling or heating operation in the shortest time (if the indoor unit does not support this function, there is no corresponding operation happened when pressing this button.)
SELF CLEAN Button Active/Disable Self Clean function. Under SELF CLEAN mode, the air conditioner will automatically clean and dry the Evaporator and keep it as fresh for the next operation.
UP Button ( ) Push this button to increase the indoor temperature setting in 1F increments to 86ºF.
DOWN Button ( ) Push this button to decrease the indoor temperature setting in 1F increments to 62ºF.
NOTE: Temperature contol is not available in Fan mode.
NOTE: Press and hold UP and DOWN buttons together for 3 seconds will alternate the temper­ature display between the ºC & ºF scale.
DRY
HEAT
FAN
o
o
AN
Remote Control
AUTO
FAN
1
2
3
4
5
ON/OFF
MODE
FAN
TURBO
SLEEP
SELF
CLEAN
TEMP
6
AUTO
SILENCE
FP
TIMER
ON
TIMER
OFF
SWING DIRECT
FOLLOW
LED
ME
7
8
9
10
11
12
13
14
8
SILENCE/FP Button
Active/Disable SILENCE function. If pushing more than 2 seconds, the “FP” function will be activated, pushing more than 2 seconds again to disable.
When the Silence function is activated, the compressor will operate at low frequency and the indoor unit will bring faint breeze, which will reduce the noise to the lowest level and creat a quiet and comfortable room for you. Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity.
Activates/Disables freeze protection”FP” or HOME-AWAY function. It can only be activated during the heating operation. (only when the setting mode is HEAT). The unit will operate at high fan speed with the temperature automatically set to 46 F. The display window of indoor unit will display FP. For the unit without display area, the Defrost indicator light will be keeping on for 2 seconds Keeps the room over freezing temperature.
9
TIMER ON Button Press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 30 minutes increments. When the setting time displays
10.0, each press will increase the auto­timed setting 60 minutes increments. To cancel the auto-timed program, simply adjust the auto-on time to 0.0.
10
TIMER OFF Button
Press this button to initiate the auto-off time sequence. Each press will increase the auto
-timed setting in 30 minutes increments. When the setting time displays 10.0, each press will increase the auto-timed setting 60 minutes increments. To cancel the auto­timed program, simply adjust the auto-off time to 0.0
11
SWING Button
Used to stop or start horizontal louver auto swing feature.
12
DIRECT Button
Used to change the louver movement and set the desired up/down air flow direction. The louver changes 6 in angle for each press.
13
FOLLOW ME Button
Push this button to initiate the Follow Me feature, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. The air conditioner will cancel the Follow Me feature automatically if it does not receive the signal during any 7 minutes interval.
14
LED Button
Disable/Active indoor screen Display. When pushing the button, the indoor screen display i s cleared, press it again to light the display.
O
Optional Wired Control
Mark of Superior Quality
Operation mode indication
Timer ON/OFF
MODEBUTTON
TIMERON BUTTON
TIMER OFF BUTTON
FOLLOW MEBUTTON
ELECTRICAL HEATER BUTTON
RESETBUTTON
1
2
1
2
3
4
5
6
All the pictures in this manual are for explanation purpose only. There may be slightly different from the wire controller you purchased(depend on model). The actual shape shall prevail.
1
ON / OFF BUTTON
7
3
Follow me function
4
ON/OFF indication
2
5
Fan speed indication
Lock
6
Temperature display zone
7
ADJUST BUTTON
8
9
ADJUST BUTTON
SWING BUTTON
10
ECONOMY BUTTON
11
FAN SPEED BUTTON
12
LOCK BUTTON
13
Page 7
Health Functions
AUTO
AUTO
FAN
ON/OFF
SHORT CUT
TIME ON
TIME
SERIES
Self Cleaning
Automacally clean & dry the evaporator coil. This will prevent proliferaon of fungus & bacteria and keep the environment healthly and comfortable
Health Functions (Optinal)
Bio Filter
This filter Consist of a specialized biological enzyme and eco filter.The eco filter catches very small airborne dust parcles and neutralies bacteria, fungi and microbes. Biological enzyme filter kills bacteria by dissolving their cell wall thus eliminang the problem of re-polluon.
Silver Ion Bacterial Filter
This an- bacterial filter kills bacteria in the air. The nano Silver aached on the filter releases the silver ions repeatedly to eliminate bacteria. Helps to control the growth of microbes, such as bacteria, fungi, virus, spores and many other harmful air pollutants by decomposing cell wall of bacteria and absorbing the cells elements. Helping to prevent mold.
Active Carbon Filter
Acve carbon is an extremely absorbent element which has dual funcon, physical and chemical absorpon. Due to its technological evoluon, acve carbon is able to absorb fast harmful gases from the environment such as petrol, formaldehyde and ammonia. Acve Carbon filter offers a clean, odorless and healthy environment.
High Density Filter
Compared with ordinary dust filter, the an-dust effect of this high density filter can increase more than 50%, it can clean dust, pollen up to 80%.
Cold Catalyst Filter
Filters the out offending odor and harmful gasses from the environment, eliminates form aldehyde and other volale organic compounds (VOCs)
Catechin Filter
They get their name from a naturally occurring bioflavonoid found in green tea that has been used in tradional medicine since ancient mes. Catechin has anviral and anbacterial properes — is infused into every molecule of these filters, which enables them to strip the passing air of odor-causing pollutants such as tobacco smoke and pet smells. An equally important benefit is that they trap and deacvate microscopic bacteria and viruses, which can diminish or prevent the spread of some diseases.
Vitamin C Filter
c
The filter is made of Vitamin C-eming material and synthec
c
c
fiber. When the air passes through this secon of the filter, Vitamin C is discharged into the room. It increases collagen producon. The filtered air soens the skin and reduces stress. This makes the indoor air feel fresh and healthy.
Compound Filter A
Combine three filters- Acve Carbon Filter + Cold Catalyst (an-formaldehyde) + Vitamin C
Compound Filter B
Combine Three Filters Catechin Filter + Nano-Ag (Silver) Ion Filter + Bio Filter
Washable Filter
The indoor unit filters can be taken out and easily washed to keep air clean all time.
Comfort Functions
Turbo Mode
When the air conditioner goes into this mode maximizes the cooling or heating capacity output cooling down or heating up the room fast.
Anti-cold Air Function (Heat Pump)
When the heating operation starts the fan coil will automatically run from the lowest speed to the preset level, so it will prevent cold air blowing out at the start of the operation avoiding discomfort too the user.
Dry Mode
In this mode the air conditioner efficiently dehumidifies the room.
Mark of Superior Quality
3 Grades Indoor Fan Speeds
3
Allow you to adjust the airflow precisely to the setting that gives you the greatest comfort.
Follow Me
When you stay close to the remote control a built-in temperature sensor senses the temperature around you and automatically chooses the operation mode to achieve an accurate and comfortable temperature just as if the air conditioner were following you.
Auto Swing
Distributes air evenly
Page 8
Convenience
AUTO
AUTO
FAN
ON/OFF
SHORT CUT
TIME ON
TIME OFF
MODE
FAN
TE
M
P
SLEEP
FRESH
TURBO SELFCLEAN
LED
FOLLOW ME
MUTE
SERIES
Dual Side Water Outlet
Multi-outlet – The refrigerant tubes and the water outlet can be installed either on the right or the left side of the unit for installation flexibility.
Washable Front Panel
The front panel can be easily removed to be washed and keep its elegant appearance.
Timer
The air conditioner can be turned on or off at any set time in a 24 hour period.
Louver Position Memory
After the user finds the best angle for the louver, when the unit restarts again the angle of the horizontal louver will automatically move to the same position set last time
Self-diagnosis and Auto-protection
!
Provides faster and accurate service diagnostics
Fire Proof Electric Box
More safer and complies with all safety regulations
Auto Re-start
The air conditioner memorizes the operation settings and when there is a power outage it will start up using these settings when the power is reestablished.
Freeze Protection
Home away winter vacation function provides piece of mind and keeps a minimum temperature of 46F during your absence preventing freezing of indoors.
Low ambient cooling
Occasionally it is necessary to cool inner room during winter .This design feature allows operation at low ambient conditions
Refrigerant Leakage Detection
Alert when refrigerant is low monitors and prevents compressor damage or overload.
Silent
Turns off the beep sound of the Buttons of remote control
Energy Savings
Sleep Mode
During sleep mode the AC will automacally increase (cooling) or decrease (heang) by 1º per hour in the first two hours and switch off aer 5 hours. The sleep mode funcon helps to maintain the most comfortable temperature and to save more energy.
Reliability
Base Pan Heater
Prevents defrost condensation
from freazing ensuring proper defrost
drainage during heating season
Mark of Superior Quality
Compressor Heater
Ensures Compressor
longevity and reliability
TwinCam
A high performance double cam twin rotary compressor increases the performance, reliability and durability
Page 9
SERIES
Klimaire Indoor Unit Model Number KSIR030-H215-I KSIR036-H215-I
Klimaire Outdoor Unit Model Number KSIR030-H215-O KSIR036-H215-O
Power supply V-ph-Hz 208-230/1/60 208-230/1/60
Capacity Btu/h 30000 36000
Power input W 2857 4235
Cooling Rated current A 12,5 18,5
EER Btu/w 10,5 8,5
SEER 18 16
Capacity Btu/h 30000 36000
Power input W 3110 3835
Heating Rated current A 13,5 16,7
COP W/W 2,8 2,8
HSPF 9,6 10
Minimum circuit ampacity (MCA) A 20 25
Max. fuse size A 30 35
Capacity Btu/h 25760 25760
Compressor Input W 2070 2070
Rated current (RLA) A 15 17
Power input W 58 58
Indoor fan motor RLA A 0,5 0,5
Speed (Hi/Med/Lo) rpm 1200/1050/950 1200/1050/750
Indoor air flow (Hi/Med/Lo) cfm 795/618/471 853/647/471
Indoor noise level (Hi/Med/Lo) dB(A) 52/44/35 52/44/36
Dimension (W*D*H) in 49.57x11.10x14.25 49.57x11.10x14.25
Indoor unit Packing (W*D*H) in 52.76x17.72x14.96 52.76x17.72x14.96
SYSTEM
Outdoor fan motor RLA A 0,6 0,6
Outdoor air flow cfm 2530 2943
Outdoor noise level dB(A) 62 63
Outdoor unit Packing (W*D*H) in 42.91x19.69x34.06 42.91x19.69x34.06
Refrigerant type oz R-410A/97.0 R-410A/119.9
Refrigerant precharge ft 25 25
Additional charge for each ft oz 0,322 0,322
Design pressure psig 550/340 550/340
Refrigerant piping Max. refrigerant pipe length ft 164 213
Connection wiring (Stranded, unshielded) AWG 16*4 16*4
Thermostat type Remote Control Remote Control
Operation temperature Outdoor (cooling/heating) - W / O, low ambient cooling ºF 32~122/5~86
Application area (cooling standard) sq ft 1400-1900 1650-2400
Net/Gross weight lb 43.2/55.6 43.2/55.6
Input W 150 150
Speed rpm 810 810
Dimension(W*D*H) in 37.24x16.54x31.89 37.24x16.54x31.89
Net/Gross weight lb 137.79/147.71 143.3/153.22
Liquid side/ Gas side in 3/8"/5/8" 3/8"/5/8"
Max. difference in level ft 82 98
Indoor (cooling/ heating) ºF 62~90/32~86
Outdoor (cooling/heating) - W, low ambient cooling ºF 5~122/5~86
62~90/32~86
32~122/5~86
5~122/5~86
6 in
D
W
H
W
Continued product improvement is our goal at Klimaire Products, Inc. Hence, specifications and data listed herein are subject to change without notice and without obligation on our part. Allways comply with local, state, and national electrical codes. 1 - Minimum 10 ft line set recommended. 2 - Outdoor unit being elevated than the indoor unit oil trap should be installed every 17 ft to 23 ft ( 5 to 7 m) 3 - Factory installed only, not field option. Units may operate in heating and cooling mode until the ambient conditions reach 5º F
D
H
Product Code
Brand K: Klimaire
Product Type M: Multi-zone Outdoor
Mark of Superior Quality
K
Unit Type I : DC Inverter
S I
Product Series
R
Nominal Capacity 036: 36,000 Btu/h 048: 48,000 Btu/h
H 2 15 A1036 I
Power Supply 1 : 115 / 60
2 : 208-230 / 1 / 60 Operational Function H: Heat Pump C: Cooling Only
O: Outdoor Dedicated
I: Indoor Unit
Nominal Efficiency SEER
Revision & Design (If any)
10
Page 10
Eco Friendly
SERIES
Accessories
115 - 230 V
Condensate Drain
Mini-Pumps
Note: The data in this brochure may be changed without notice for further improvement on quality and performance
WAFB21
Outdoor unit wall brackets
WAFP24
IKM3858F_ _ C _ _
EZ - Quick installation kits
16, 25, 35, 50 ft.
AQS-0066-11
Aqua Over-Flow Switch
2190 NW 89th Place Doral, FL 33172 - USA e-mail: sales @klimaire.com www.klimaire.com
Mark of Superior Quality