ADVANCED TECHNOLOGY
ENERGY SAVINGS
ECO-FRIENDLY
QUICK & EASY INSTALLATION
Mark of Superior Quality
Page 2
SERIES
We have been in the Ductless Mini-Split business for over 25 years, Klimaire manufacturing maintains the
What Klimaire
brings you …
Ductless Mini-Split systems are one of the fastest growing products in the US and popularity is rapidly increasing. They allow air
conditioning and heating systems to be added quickly, economically and conveniently, often for some applications where installing comfort
systems didn't seem possible or practical.
Flexibility is the main driver of their popularity. Klimaire ductless systems are simple, reliable, easy to install, and extremely affordable.
Klimaire slim single zone and multi zone ductless systems offer built-in solutions with duct free technology benefits. These systems are
integrated with innovative inverter technology providing individual comfort and control. With our KSIX series we are committed to bring our
valued customers additional savings with a unit almost ready to install, easily and quickly, with minimum HVAC technician assistance.
highest standards of quality and reliability with ISO 9001 and ISO 14001a. Our products have proven their
endurance and resiliency over time, operating in 70 different countries. All products are ETL certified and AHRI
registered. Klimaire products exceed industry standards for energy efficiency and employ innovative
technology to achieve the highest customer satisfaction. Since our goal is to achieve maximum customer
satisfaction, we continuously seek to achieve higher performance levels in the design phase for all future units.
How much do you spend for
heating & cooling your home?
The US Department of Energy (DOE) says that as much as half of
the energy used in your home goes to heating and cooling. So
making smart decisions about your home's heating, ventilating, and
air conditioning (HVAC) system can have a big effect on your utility
Klimaire Invertech DC Inverter - driven ductless air conditioners and
heat pumps can save you up to 33% on your power utility bill when compared with
room air conditioners or standard efficiency 10 SEER ductless systems.
Ductless Invertech units are practical to install and preferred over traditional ducted central units.
Total savings can reach up to 49% when heat pump technology is combined with an inverter system.
49%
Heating & Cooling
8% Other*2% Dishwasher
5% Refrigerator
10% Lighting
13% Water Heating
Clothes Washer
& Dryer
6%
7% Electronics
What is Klimaire DC Inverter?
Klimaire DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called “DC inverter” because
the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency.
As known, the current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor
will result different running speeds of the compressor. Klimaire Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most
advanced and energy efficient method of inverting the current. DC Inverter air conditioners bear special compressors that their speed could be
changed by increasing or decreasing the frequency of the supplied power.
Therefore, unlike conventional split Air Contioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will
monitor the room temperature and adjust the compressor speed automatically. Conventional compressors turn on and off to maintain the room
temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of
the compressor and other components that are turning on
and off.
Once a conventional system is running, it runs at its
maximum speed, consuming the maximum amount of
energy in order to produce the maximum of cooling or
heating to maintain the desired temperature. The system
will then cycle between on and off in an effort to maintain this
temperature. When a DC Inverter compressor initially
starts up, it runs with a higher speed to bring the room
temperature to desired level rapidly, Once the set
temperature is reached, it slows down and adjust its
capacity just to counter the heat loss or heat gain of the
building. By this way it will maintain a constant temperature.
Set
Temp.
Room Temp.
T2
T1
Fixed Speed AC
DC Inverter AC
Too Hot
Comfortable
Too Cold
Time
Ducted vs Ductless Systems
According To the US Department of Energy (energy.gov) “Since mini splits have no ducts ,they avoid the energy losses
associated with ductwork of central forced air systems. Duct losses can account for more than 30% of energy consumption
for space conditioning especially if the ducts are in an unconditioned space such as attic.”
You´ll save energy every time you use a Klimaire Ductless System.
Air ducts from a central forced air system can lose energy more than 30%, with air leakage especially
if the ducts run through unconditioned areas like attics or basements.
Since Klimaire Ductless Systems have no ducts, they avoid that energy loss completely,
reducing your impact on the environment and lowering your energy costs.
Only one temperature control for all the zones, conflicting with individual comfort preferences
Mark of Superior Quality
2
Page 3
Supply air
Temperature
at grille outlet
is aprox. 5°F less
than in unit outlet.
Ductwork in
the attic space
SERIES
Ducted Systems Vs Ductless Systems
Unconditioned attic space
Summer temperature reach up to 125° F
Winter temperatuers reach down to 25° F
Duct losses can reach up to 30% due to
leakage & temperature differences between
grilles and the unit outlet
Colder air in duct
gets less cold reaching
to grille outlets
ATTIC CONDITION
IN SUMMER
SEASON
Typical Single
Family Summer
Condition
HOT A
T
TIC SPACE
56° Leaving
Temp.
Return Air 75°F
60°F
Supply Temp.
Summary: Duct Losses Can Be Over 30%
Ductless Mini-split
Experience true individual comfort. Ductless Mini-Split systems
are the perfect solution to a variety of installation challenges.
Ductless Mini-Split units eliminate the use of ductwork, allowing
installers the ability to place these units in locations that were
previously considered impractical or impossible due to
additional ducting and cost associated with installing a regular
unit. Ductless Mini-Splits consist of two parts, an outdoor unit
and an indoor unit, similar to regular split units, but much
smaller in size. The outdoor and indoor units are connected to
each other by refrigerant and electrical lines. They run together
with a condensate drain line through a small hole in an exterior
wall, generally 3 inch in diameter or less. In addition to
eliminating the need for ducting, another great advantage of
Ductless Mini-Split systems is true zone control. The indoor fan
coil unit is dedicated to the room being conditioned, allowing a
temperature and humidity level to be kept in a specific room,
separate from the rest of the house or building.
Personalized Comfort Solution
OUTDOOR UNIT
Indoor Unit / Evaporator
COLD A
T
TIC SPACE
Return
Air 70°F
OUTDOOR UNIT
Conduit for
Refrigerant
Lines
& Wiring
Temperature
leaving the A.H.U.
AIR HANDLING UNIT (AHU)
ATTIC CONDITION
IN WINTER SEASON
Typical Single Family
85°F
Supply Temp.
OUTDOOR UNIT
Wall mounted outdoor unit
Outdoor Unit
/ Condenser
Winter Condition
40°
Leaving
Temp.
3
Page 4
Total Comfort
SERIES
Auto swing air swipe
Oscilating Louver Technology
distribute air evenly throughout
the room with horizontal
auto swing function
Long range air discharge
Powerful and silent air flow
thru larger fan diameter
to reach every spot
of the room
New Design
KSIR fan diameter
increased, air blow
distance farther,
air flow volume bigger
3 fan speeds
2
1
Turbo mode
Quiet & Efficient
Low Noise Design
Optimize air discharge vane
Silent Mode
3
M ax
Decrease
3. 5dB(A )
Indoor fan
run at an
extra breeze
Allow you to adjust
the airflow precisely
to the setting that
gives you the
greatest comfort
Turbo function enables
the unit to reach the preset
temperature at cooling
or heating operation
in the shortest time
Independient Humidity Control
Unique Comfort in Cooling & Heating
Room temperature 77ºF
Humidity 50% COMFORTABLE
Decreasing humiditywhile maintaining
the temperature increases comfort
Room temperature 77ºF
Humidity 80% UNCOMFORTABLE
Hot and stuffy with high humidity
Since humidity is a major factor for comfort, Klimaire DC INVERTER adjusts to summer and winter
months – driven variable speed compressors reduces capacity to match lighter loads, increasing
the run time to remove moisture and reduce relative humidity resulting in improved comfort. In the
winter, by increasing the speed of the compressor,
Klimaire air conditioner and heat pump systems
are able to maintain capacity and deliver warmer
supply air even at low outdoor ambient conditions
as low as 5°F
Convenience
ON/OFF 24 hr. Programmable Timer
Louver Position
Memory Function
When you start the
unit, the horizontal louver
will return automatically
to the same position
that was set last time
Timer can be set ON/OFF easily upto 24 hours using the wireless remote
control (Set time: 0.5, 1, 1.5, 2, 2.5,...)
9 PM
Set
10 hr.
Set your confort
OFF
3 hr.
12
7
6
ON
preferences
-
Dry mode function in remote
Remote Control
39
TIMER
OFF
11 hr.
During DayDuring Night
Set your confort
preferences
+
12
39
7
6
ON
4
Page 5
SERIES
EASY MAINTENANCE
Micro –Processor Control
Self Diagnostic function monitors and displays working
conditions and provides auto protection.
Service Friendly
* Emergency Function Using
Manual Switch Button
•
Easy to turn on/off without a tool.
ü
Emergency Using Function
•
Smartly detecting errors, your unit
ü
keep running when in urgent need
Old Design
.
New Design
PRODUCT HIGHLIGHTS
Klimaire Invertech DC inverter -driven air conditioners and
heat pumps are among the most ultimate in cooling and
heating technology available in HVAC.
Energy savings are much higher with this INVERTECH DC
INVERTER - driven variable speed compressor.
Thin & Slim design
Thin and slim design is realized
by multi-bend high efficient
hydrophilic fin heat exchanger
and high efficiency blower wheel.
MULTI-BEND
HYDROPHILIC
HEAT EXCHANGER
Low ambient heating & cooling
* KSIF series have the ability to produce heat in ambient conditions down to 5° F
* KSIF series operates in cooling mode in the low winter ambient conditions
donw to 5° F when heating is necessary in spaces like server rooms, sun
rooms & hydroponic nurseries.
The outdoor unit is engineered with specialized sensors and dual heater
technology such as base pan and crankcase heaters enabling it to operate
in harsh conditions as low as 5° F
Homeowners and
neighbors enjoy the quiet
whisper of the outdoor
units operation, less
noise to the surroundings
keeps the environment
peaceful.
Leakage Detection
* You will be alerted when
refrigerant is low.
* Preventes damage to the
compressor
* Automatically turns off the unit
LARGE AIR INTAKE
HIGH EFFICIENCY
BLOWER WHEEL
°F
104
86
68
50
32
10
-4
122
COOLING
°F
°F
86
HEATING
°F
15
°F
5
11.1 in
Self Cleaning
Self Cleaning
Your Klimaire KSIE series equiped with
Auto Clean Function. It cleans and dries
the evaporator to prevent mildew grow
and keep it fresh for next operation.
Interactive display
When I show these codes on the display, that means ...
ü I’m defrosting.
DF
ü I’m dirty, please
CL
clean my filters up
ü That means you switch
ON
OF
“Turbo Mode” on
.
ü That means you switch
“Turbo Mode” off
When you press any function button
ü My filters are too old, please
NF
change new ones for me.
Turbo
Indoor Air Quality (IAQ) Options
BIO FILTERCOMPOUND FILTER SILVER ION FILTER HIGH DENSITY FILTER CARBON FILTER
Operation
Time
(minute)
Low Fan
Only
1-13
Heating
& Low Fan
14
c
CATECHIN FILTERVITAMIN C FILTER
Low Fan
Only
15-16
5
Page 6
SERIES
1
ON/OFF Button
This button turns the air conditioner ON
and OFF.
2
MODE Button
Press this button to modify the air conditioner
mode in a sequence of following:
AUTO
NOTE: Please do not select HEAT mode if the
machine you purchased is cooling only type.
Heat mode is not supported by the cooling
only appliance.
3
FAN Button
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
NOTE: You can not switch the fan speed in
AUTO or DRY mode.
4
SLEEP Button
For the detail, see “sleep operation” in
“USER´S MANUAL”.
5
6
7
COOL
Active/Disable sleep function. It can
maintain the most comfortable temperature
and save energy. This function is available
on COOL, HEAT or AUTO mode only .
NOTE: While the unit is running under SLEEP
mode, it would be cancelled if MODE, F
SPEED or ON/OFF button is pressed.
TURBO Button
Active/Disable Turbo function. Turbo function
enables the unit to reach the preset temperature at cooling or heating operation in the
shortest time (if the indoor unit does not
support this function, there is no
corresponding operation happened when
pressing this button.)
SELF CLEAN Button
Active/Disable Self Clean function.
Under SELF CLEAN mode, the air
conditioner will automatically clean and dry
the Evaporator and keep it as fresh for the
next operation.
UP Button ( )
Push this button to increase the indoor
temperature setting in 1F increments to 86ºF.
DOWN Button ( )
Push this button to decrease the indoor
temperature setting in 1F increments to 62ºF.
NOTE: Temperature contol is not available
in Fan mode.
NOTE: Press and hold UP and DOWN buttons
together for 3 seconds will alternate the temperature display between the ºC & ºF scale.
DRY
HEAT
FAN
o
o
AN
Remote Control
AUTO
FAN
1
2
3
4
5
ON/OFF
MODE
FAN
TURBO
SLEEP
SELF
CLEAN
TEMP
6
AUTO
SILENCE
FP
TIMER
ON
TIMER
OFF
SWING DIRECT
FOLLOW
LED
ME
7
8
9
10
11
12
13
14
8
SILENCE/FP Button
Active/Disable SILENCE function. If pushing
more than 2 seconds, the “FP” function will
be activated, pushing more than 2 seconds
again to disable.
When the Silence function is activated, the
compressor will operate at low frequency
and the indoor unit will bring faint breeze,
which will reduce the noise to the lowest
level and creat a quiet and comfortable room
for you. Due to low frequency operation of
compressor, it may result in insufficient
cooling and heating capacity.
Activates/Disables freeze protection”FP”
or HOME-AWAY function. It can only be
activated during the heating operation.
(only when the setting mode is HEAT).
The unit will operate at high fan speed with the
temperature automatically set to 46 F. The
display window of indoor unit will display FP.
For the unit without display area, the Defrost
indicator light will be keeping on for 2 seconds
Keeps the room over freezing temperature.
9
TIMER ON Button
Press this button to initiate the auto-on
time sequence. Each press will increase
the auto-timed setting in 30 minutes
increments. When the setting time displays
10.0, each press will increase the autotimed setting 60 minutes increments.
To cancel the auto-timed program, simply
adjust the auto-on time to 0.0.
10
TIMER OFF Button
Press this button to initiate the auto-off time
sequence. Each press will increase the auto
-timed setting in 30 minutes increments.
When the setting time displays 10.0, each
press will increase the auto-timed setting
60 minutes increments. To cancel the autotimed program, simply adjust the auto-off
time to 0.0
11
SWING Button
Used to stop or start horizontal louver auto
swing feature.
12
DIRECT Button
Used to change the louver movement and set
the desired up/down air flow direction.
The louver changes 6 in angle for each press.
13
FOLLOW ME Button
Push this button to initiate the Follow Me
feature, the remote display is actual
temperature at its location. The remote
control will send this signal to the air
conditioner every 3 minutes interval until
press the Follow Me button again. The air
conditioner will cancel the Follow Me feature
automatically if it does not receive the signal
during any 7 minutes interval.
14
LED Button
Disable/Active indoor screen Display. When
pushing the button, the indoor screen display i
s cleared, press it again to light the display.
O
Optional
Wired
Control
Mark of Superior Quality
Operation mode indication
Timer ON/OFF
MODEBUTTON
TIMERON BUTTON
TIMER OFF BUTTON
FOLLOW MEBUTTON
ELECTRICAL
HEATER BUTTON
RESETBUTTON
1
2
1
2
3
4
5
6
All the pictures in this manual are for explanation purpose only. There may be
slightly different from the wire controller you purchased(depend on model). The
actual shape shall prevail.
1
ON / OFF BUTTON
7
3
Follow me function
4
ON/OFF indication
2
5
Fan speed indication
Lock
6
Temperature display zone
7
ADJUST BUTTON
8
9
ADJUST BUTTON
SWING BUTTON
10
ECONOMY BUTTON
11
FAN SPEED BUTTON
12
LOCK BUTTON
13
6
Page 7
Health Functions
AUTO
AUTO
FAN
ON/OFF
SHORT
CUT
TIME
ON
TIME
SERIES
Self Cleaning
Automacally clean & dry the
evaporator coil. This will prevent
proliferaon of fungus & bacteria
and keep the environment healthly
and comfortable
Health Functions (Optinal)
Bio Filter
This filter Consist of a specialized biological enzyme
and eco filter.The eco filter catches very small airborne
dust parcles and neutralies bacteria, fungi and
microbes. Biological enzyme filter kills bacteria by
dissolving their cell wall thus eliminang the problem
of re-polluon.
Silver Ion Bacterial Filter
This an- bacterial filter kills bacteria in the air.
The nano Silver aached on the filter releases the silver
ions repeatedly to eliminate bacteria. Helps to control
the growth of microbes, such as bacteria, fungi, virus,
spores and many other harmful air pollutants by
decomposing cell wall of bacteria and absorbing the
cells elements. Helping to prevent mold.
Active Carbon Filter
Acve carbon is an extremely absorbent element
which has dual funcon, physical and chemical
absorpon. Due to its technological evoluon, acve
carbon is able to absorb fast harmful gases from the
environment such as petrol, formaldehyde and
ammonia. Acve Carbon filter offers a clean, odorless
and healthy environment.
High Density Filter
Compared with ordinary dust filter, the an-dust effect
of this high density filter can increase more than 50%,
it can clean dust, pollen up to 80%.
Cold Catalyst Filter
Filters the out offending odor
and harmful gasses from the
environment, eliminates form
aldehyde and other volale
organic compounds (VOCs)
Catechin Filter
They get their name from a naturally occurring bioflavonoid
found in green tea that has been used in tradional medicine
since ancient mes. Catechin has anviral and anbacterial
properes — is infused into every molecule of these filters,
which enables them to strip the passing air of odor-causing
pollutants such as tobacco smoke and pet smells. An equally
important benefit is that they trap and deacvate microscopic
bacteria and viruses, which can diminish or prevent the spread
of some diseases.
Vitamin C Filter
c
The filter is made of Vitamin C-eming material and synthec
c
c
fiber. When the air passes through this secon of the filter,
Vitamin C is discharged into the room. It increases collagen
producon. The filtered air soens the skin and reduces stress.
This makes the indoor air feel fresh and healthy.
Compound Filter A
Combine three filters- Acve Carbon Filter
+ Cold Catalyst (an-formaldehyde) + Vitamin C
Compound Filter B
Combine Three Filters Catechin Filter
+ Nano-Ag (Silver) Ion Filter + Bio Filter
Washable Filter
The indoor unit filters can be taken out
and easily washed to keep air clean all
time.
Comfort Functions
Turbo Mode
When the air conditioner goes into this mode
maximizes the cooling or heating capacity output
cooling down or heating up the room fast.
Anti-cold Air Function (Heat Pump)
When the heating operation starts the fan coil
will automatically run from the lowest speed to
the preset level, so it will prevent cold air blowing
out at the start of the operation avoiding
discomfort too the user.
Dry Mode
In this mode the air conditioner efficiently
dehumidifies the room.
Mark of Superior Quality
3 Grades Indoor Fan Speeds
3
Allow you to adjust the airflow precisely
to the setting that gives you the greatest comfort.
Follow Me
When you stay close to the remote control a built-in
temperature sensor senses the temperature around you
and automatically chooses the operation mode to achieve
an accurate and comfortable temperature just as if the air
conditioner were following you.
Auto Swing
Distributes air evenly
7
Page 8
Convenience
AUTO
AUTO
FAN
ON/OFF
SHORT
CUT
TIME
ON
TIME
OFF
MODE
FAN
TE
M
P
SLEEP
FRESH
TURBO SELFCLEAN
LED
FOLLOW ME
MUTE
SERIES
Dual Side Water Outlet
Multi-outlet – The refrigerant tubes and the water
outlet can be installed either on the right or the
left side of the unit for installation flexibility.
Washable Front Panel
The front panel can be easily removed to be
washed and keep its elegant appearance.
Timer
The air conditioner can be turned on or off at
any set time in a 24 hour period.
Louver Position Memory
After the user finds the best angle for the louver,
when the unit restarts again the angle of the
horizontal louver will automatically move to the same
position set last time
Self-diagnosis and Auto-protection
!
Provides faster and accurate service diagnostics
Fire Proof Electric Box
More safer and complies with all safety regulations
Auto Re-start
The air conditioner memorizes the operation settings and
when there is a power outage it will start up using these
settings when the power is reestablished.
Freeze Protection
Home away winter vacation function provides piece of
mind and keeps a minimum temperature of 46F during
your absence preventing freezing of indoors.
Low ambient cooling
Occasionally it is necessary to cool inner room
during winter .This design feature allows
operation at low ambient conditions
Refrigerant Leakage Detection
Alert when refrigerant is low monitors and
prevents compressor damage or overload.
Silent
Turns off the beep sound of
the Buttons of remote control
Energy Savings
Sleep
Mode
During sleep mode the AC will automacally increase
(cooling) or decrease (heang) by 1º per hour in the
first two hours and switch off aer 5 hours.
The sleep mode funcon helps to maintain the most
comfortable temperature and to save more energy.
Reliability
Base Pan Heater
Prevents defrost condensation
from freazing ensuring proper defrost
drainage during heating season
Mark of Superior Quality
Compressor Heater
Ensures Compressor
longevity and reliability
TwinCam
A high performance double cam
twin rotary compressor increases the
performance, reliability and durability
8
Page 9
SERIES
Klimaire Indoor Unit Model NumberKSIR030-H215-IKSIR036-H215-I
Klimaire Outdoor Unit Model NumberKSIR030-H215-OKSIR036-H215-O
Power supplyV-ph-Hz208-230/1/60208-230/1/60
Capacity Btu/h3000036000
Power input W28574235
CoolingRated current A12,518,5
EER Btu/w10,58,5
SEER1816
Capacity Btu/h3000036000
Power input W31103835
HeatingRated current A13,516,7
COPW/W2,82,8
HSPF9,610
Minimum circuit ampacity (MCA)A2025
Max. fuse sizeA3035
Capacity Btu/h2576025760
CompressorInput W20702070
Rated current (RLA) A1517
Power input W5858
Indoor fan motorRLAA0,50,5
Speed (Hi/Med/Lo)rpm1200/1050/9501200/1050/750
Indoor air flow (Hi/Med/Lo)cfm795/618/471853/647/471
Continued product improvement is our goal at
Klimaire Products, Inc. Hence, specifications and
data listed herein are subject to change without
notice and without obligation on our part. Allways
comply with local, state, and national electrical
codes.
1 - Minimum 10 ft line set recommended.
2 - Outdoor unit being elevated than the indoor
unit oil trap should be installed every 17 ft to 23 ft (
5 to 7 m)
3 - Factory installed only, not field option. Units
may operate in heating and cooling mode until the
ambient conditions reach 5º F