Please thoroughly read this manual to operate the air-conditioner correctly and safety to prevent
the damage of the property and the personal hurt.
Before you come to the text, please be familiar with the following markers and icons, and
comply with the precautions.
Markers
Icons
Markers
The sign shows the risk of
WARNING
!
CAUTION
!
death or serious injury will
be caused due to the wrong
operation .
The sign shows the risk of
injury or the damage to the
property will be caused due
to the wrong operation.
Indication
Icons
FORBID
Followed by the detailed illustration
ENFORCE
Followed by the detailed illustration
Indication
NOTE :
1. Injury means causing from the harm, burn and electrical shock , but not serious for the
hospitalization.
2. The damage of material means the disrepair of property and material.
WARNING
!
Please entrust the dealer or the professional person to do the
installation.
Installation
commitment
Users cant install the units by themselves, or the water leakage,
electrical shock or fire may be caused..
Accessories must be specified
Humidifier and other accessories must be specified, otherwise
Please use the
specified product.
the water leakage, electrical shock or fire may be caused. Please
entrust the professional person to do the installation.
When installing in a small room, actions should be taken in
case the thickness of refrigerant exceeding proper range.
Take measure to prevent
the refrigerant leakage from
Otherwise, it will cause people asphyxia.
Please contact the dealer to avoid the asphyxial accident.
the asphyxial accident.
INSTALLATION WARNING
Ensure grounding correctly.
Grounding
Defective grounding may cause electrical shock.
1
Page 4
WARNING
!
Forbid
Forbid
Do not face the cool wind for a long time.
Too low temp.will do harm to the health.
Never put hands or objects into the air conditioner.
The fan with the high speed will cause serious injury.
Using warning
Turn off the
power.
Forbid
Moving warning
Forbid
Ensure the drainage.
Ensure the creepage
protection switch.
In any abnormal cases, stop the operation, turn off the power and
consult the dealer.
In the abnormal cases, if keeping on the operation ,the fire and electrical
shock will be caused.
Please entrust the dealer or professional person to move and reinstall
the air-conditioner.
Incorrect installation will cause water leakage, electrical shock or fire.
Do not maintain the unit by yourself.
Incorrect maintenance will cause water leakage, electrical shock or fire.
Ensure if the drain pipe can drain the water well.
Incorrect installation will cause water leakage and humidify the furniture.
Ensure the installation of creepage protection switch.
The creepage protection switch must be installed. Otherwise, the
electric shock will be caused.
Installation caution
Ensure the installation
place.
Ventilate
Forbid
User caution
Ensure the installation
bracket.
Never install the air-conditioner in the place where the flammable
gas is easy to leak.
If the leakage of flammable gas happens, the fire will be caused around
the indoor unit.
Ventilation should be operated regularly when using with the
flammable appliance.
Insufficient ventilation will cause the lack of oxygen.
Do not put the flammable appliance near the air outlet.
It will cause the flammable appliance burn incompletely.
Ensure whether the installation bracket has been worn out after
being used for a long time.
In the case of abrasion to put the unit on the bracket will cause the
unit falling and cause people injured.
2
Page 5
Forbid
Forbid
Forbid
Forbid
User caution
Forbid
Forbid
Turn off the power
Do not wash the air conditioner with water.
Electric shock will be caused.
Do not put animal or plant near the air outlet.
It is harm to the animal and plant.
Do not put the flammable sprayer near the air conditioner or
spray the air conditioner directly.
The fire will be caused.
Do not put the container with water on the air conditioner.
Immersion of water will reduce the ability of insulation and the electric
shock will be caused.
Do not operate the switch with wet hand.
The electric shock will be caused.
The air conditioner can not be used to conserve food, plant, precision
instrument and artworks etc..
It will get the quality worse.
Disconnect the power and stop the operation when repairing.
The fan with high speed will cause injury.
Do not use the fuse whose capacity exceeds the defined value.
Using the iron wire or brass wire as fuse can cause the fire and malfunction.
Use the right fuse
The power must use the specified circuit under the rated voltage.
Note Before Operation
Confirm Before Operation
Make sure that the ground wire is not broken or fallen off.
Make sure the air filter is installed.
Turn on the power switch for 12 hours before the operation.
About Heating Capacity
Heating is that the outdoor unit absorbs the outdoor heat then transmit the heat to the indoor unit.
When the heating pump starts, the outdoor unit blows the cold air and the outdoor temp. fall.
Defrosting during the Heating Operation
Under the heating mode ,when frost generating on the outdoor unit the air conditioner starts
defrosting automatically. (About 2~10minutes)
Indoor/Outdoor fan stops the running during the defrosting.
About 3 Minutes Protection
The outdoor unit would not run within 3 minutes during restarting. This is self-protection of the
unit.
3
Page 6
About Power Off
All the operations will stop if there is a power off.
The buzzer of the display will make a sound and the operation indicator will flash when the power is
on after a failure.
Press ON/OFF button to restart the unit.
About Protection Device
when starting the unit compulsorily while the unit does not prepare for the starting, the on/off indicator lights,
the protection device is activated and the unit stops.
Heating Capacity Drop
When the outdoor temp. is low the heating capacity drop, please use the air- conditioner with other
heating equipments or purchase the digital scroll central air-conditioner auxiliary heating device.
When the Protection Device is Activated
Cooling Operation
The air Intake and the air outlet of the outdoor unit are blocked.
Strong wind outside is blowing into the air outlet of the outdoor unit.
Heating Operation
The air filter is too dirty.
The air intake and the air outlet of the indoor unit are blocked.
Fan Runs after the Indoor Unit Stopped
To protect the machine, one of the indoor units, which stops the running while the other indoor units are still
running, will run its fan at low speed for 3 minutes every 1 hour on cooling operation or every 4 hours on heating
operation.
CAUTION
Confirm the air filter is installed. The heat exchanger would accumulate dust or leak water
without the air filter.
One indoor unit can run alone, or run with other indoor units, but can not run under heating
mode while others run under cooling mode.
4
Page 7
CAUTION
Do not disconnect the power.
Do not disconnect
the power.
Do not disconnect the power when the unit
is in operation. Please control it with the
remote controller.
Connect to the power 12 hours before
starting the unit
12 hours before
Put the louver horizontally when
cooling.
There will be water condensing on the louvers if
setting the louvers down when cooling.
(Cassette type only)
Place it away from TV or radio.
To protect the compressor, please turn on
the power switch 12 hours before starting
the unit.
One of the indoor units can not run on
the cooling mode while the other indoor
units run on the heating mode.
Please run every indoor unit on the same mode.
Put the TV or radio away from the air
conditioner at least 1 meter, or signal will
be interfered.
5
Page 8
Parts Identification
Four-Way Cassette Type
Grounding Screw (In the control box)
Air Out Louver (Adjustable)
Two-direction or Three-direction Air Outlet
For the detailed information please consult
your local dealer.
Lock buckle (For closing the Air Grille)
Air Intake (Intake air from here)
Air Filter (Filter the dust in the intake air)
Ceiling-Floor Type
Air Outlet Horizontal Louver
Air Intake
(Intake room air here)
Air Filter
(Filter the dust in the air)
6
Page 9
Duct/Ceiling Type
Air Outlet
(Connect the duct)
Grounding Screw
(In the control box)
Air Intake
(Intake room air here)
Lock Buckle
(For closing the air intake grille)
Air Filter
(Filter the dust in the air)
(Thin) Duct/Ceiling Type
Air Outlet
(Outlet room air)
Heat Exchanger
(Exchange cool air into warm air)
Air Intake
(Intake room air here)
Indoor unit
Electric control box
7
Page 10
Operation
Please note the following correct operation for saving energy and achieve the quick and comfortable
cooling/heating effects.
Clean the air filter regularly
The blocked air filter will reduce cooling/heating
effects.
Check
regularly
Close the door/window
Do not let the heat/cool air leak from the door/
widow.
Close the door/window
Do not overcool or overheat
WARNING
!
Do not expose you to the cool wind
for a long time. Over-cool is harm to
your health.
Especially for the handicapped, children or old.
Suggested Temperature
Cooling
Heating
To maintain the comfortable temperature
Adjust the air-out direction with using the air-out
louver.
78~82 F
71~75 F
Prohibit
Do not
overcool
Cooling
Heating
Meet the following requirements to use
the air conditioner correctly.
Outdoor
Temperature
Indoor
Temperature
Indoor Humidity
80% humidity or above will cause the
machine surface condensing dew.
Outdoor
Temperature
Indoor Temperature
-59 F~ 109 F
32 ~109 F
F
Below 80%
-59 F~ 75 F
Below 82 F
8
Protection device will be
activated and the unit stops
when the above conditions
can not satisfy.
Page 11
ADJUSTING THE AIR FLOW DIRECTION
Becausecoldairflowdown and hotair flowup, toimprovethecoolingandheatingeffect,
please adjust air flow louver direction , in result the temperature of the room will be natural and
equal and you will fell more comfortable.
NOTE : The heating operation with horizontal air out let will increase the difference of the room
temperature.
!
Notice Notice the
louver
direction
Four-Way Cassette Type
Cooling operation
Adjust the louver horizontally .
When using the panel with auto.louver, press SWING button , the auto.louver will swing automatically
and the best cooling (heating) effects will be achieved.
Duct-Ceiling Type
The following is how to adjust the air flow direction when the air outlet parts (sold separately) is
used with the indoor unit.
Choose horizontal outlet mode when cooling operation
When the cooling operation ,the air flow down will cause condensing
dew on the air outlet and louver surface.
Heating operation
Adjust the louver down.
Heating
To effectively heat the bottom of the room
please set the louver downwards.
9
Page 12
Ceiling-Floor Type
Auto-swing
Press SWING button, the louver will swing
up and down(left and right) automatically.
When cooling
Adjust the louver horizontally.
MAINTENANCE
Manual Swing
Adjust the louver to achieve better cooling/
heating effects when cooling/heating.
When heating
Adjust the louver downwards (vertically).
CAUTION
Only the specialized maintenance person can perform the maintenance work.
The main power switch must be turned off before doing electrical connection or cleaning the air filter.
Do not use water or air of temperature above 122 F to clean the air filter or the panel.
METHOD FOR CLEANING THE AIR FILTER
The air filter can prevent the dust or other particles from going inside. In case of blockage of the filter, the
working efficiency of the air conditioner may greatly decrease. Therefore, the filter must be cleaned once two
weeks during long time using.
If the air conditioner is positioned in a dust place, the cleaning frequency of the air filter must be increased.
If the accumulated dust is too heavy to be cleaned, please replace the filter with a new one(the replaceable air
filter is an optional fitting).
1. Take out the air-in grill
Four- Way Cassette Type
Push the grill switches towards the middle simultaneously as indicated in sketch A. Then pull down the air-in grill. Take
out the air-in grill (together with the air filter shown in Sketch B).Pull the air-in grill down at 113 F and lift it up to take out
the grill.
Cautions: The control box cables, which are originally connected with the main body electrical terminators
must be pulled off before doing as indicated above.
10
Page 13
For Duct/Ceiling Type
Push the grill switches to the arrow directions , then open the air-in grill downwards. Turn back the air filter fixing block,
then take out the air-in grill.
2. Dismantle the air filter.
3. Clean the air filter(vacuum cleaner or pure water may be used to clean the air filter. If the dust accumulation is too
heavy, please use soft brush and mild detergent to clean it and dry out in the cool place).
A
B
MAINTENANCE
The air-in side should face up when using vacuum cleaner.
The air-in side should face down when using water.
Cautions : Do not dry out the air filter under direct sunshine or with fire.
For the one-way cassette type , the air filter should be installed before the unit body installation.
4. Re-install the air filter.
5.
Install and close the air-in grill in the reverse orders of step 1 and 2 and connect the control box cables to the
corresponding terminators of the main body.
CLEANING THE AIR OUTLET AND THE PANEL
Use a dry and soft cloth to wipe it.
Pure water or mild detergent may be used if it is very dirty.
CAUTIONS
Do not use benzene, thinner, polishing power, or similar solvents for cleaning. These may cause the surface to
crack or deform.
To avoid the risk of electrical shock or fire, do not let water fall into the indoor unit.
Never wipe the air flow louver violently.
An air conditioner without air filter can not expel the dust out of the room, which would cause malfunctions by
accumulation.
MAINTENANCE OF THE OUTDOOR UNIT
1. Injures may happen by improper operations because of the sharp blade of some plates and the freezer.
2. Check the air outlet and the air inlet of the outdoor unit regularly to ensure that they are not choked by filth or
soot.
3. The coil and other parts of the outdoor unit should also be checked regularly. Please contact with your
local dealer.
11
Page 14
IF YOU DO NOT PLAN TO USE THE UNIT FOR A LONG TIME
Operate the fan for about half a day to dry the inside of the unit.
Turn off the unit with the ON/OFF button on the remote controller,then disconnect the power.
NOTE
When the power switch is connected, some energy will be consumed, even if the unit is not in operation. So
please disconnect the power to save energy.
A degree of filth will be accumulated due to certain performance after several seasons of operation. So special
maintenance is advised.
Take out of the batteries from the remote controller.
RESTART AFTER A LONG TIME
1. Check before operation
Check the air outlets or inlets of the indoor/ outdoor unit are not blocked.
Check the grounding wire is not broken off and is connected well.
2. Restore the air filter and the front panel
The air filter and the front panel must be fixed to the original position after having been cleaned.
3. Connect the main power switch
To protect the air conditioner, power should be provided 12 hours before operation. Then the OPERATION
lamp on the control box of the indoor unit will flash once a second.
AIR-CONDITIONER AUXILIARY HEATING EQUIPMENT
In winter, due to the difference of the area and building construction, please purchase the indoor unit with auxiliary heating
to enlarge the heating capacity. When turning to the heat mode the air-conditioner with auxiliary heating will run at the set
temp. .Its no need to install auxiliary heating equipments on site for 4-way cassette type and duct/ceiling type (with
auxiliary heating).
,
12
Page 15
ABNORMAL PHENOMENON
Please read the following illustration before applying for the service:
Troubles Causes
From outdoor unit
white cold fog and condensing dew.
hiss and poop are heard.
From indoor
Hiss for once.
unit
Hiss and poop are heard.
Abnormal smell blown out.
Operation lamp flashes.
Noise, hydrometeor and
Not malfunction
cold air appear when the
running stops.
Kshacan be heard
when start.
Fan function stop automatically to defrost. It
is the start and stop sound of the electromagnetic valve.
At the beginning and ending of the running
process, sounds like water flow in valve
appears, and be enhanced at the first 2~3
minutes, this is refrigerant flow sound.
Slight hiss and poop are caused by mild
flexing of the heat exchanger as temperature
changes.
Pieces of the wall, carpet, furniture, cloth,
cigarette and cosmetics adhere to the unit.
Connect to the power after the power cut.
Other equipments heating process stops the
cooling operation.
The operator sets an opposite mode against
the fixed cooling and heating mode.
The refrigerant will suddenly move to avoid
resorting in the indoor unit, then caused
kak sounds.Hydrometeor or cold air appears
when other indoor unit is heating or cooling.
The sound of the expansion valve when
supplied power.
Stop running automatically.
No operation
If the timer reached the set time.
If no power.
If the fuse is blown.
If starting the protection device (the operation
lamp lights).
If the timer is on the set time.
If choosing the cooling and heating simultan-
Check it
again
Insufficient cooling
Insufficient heating
eously.
If the outdoor unit air inlet or outlet is
blocked.
If the doors and windows are open.
Do not
work
If the dust filter is choked by collective dust.
If the air louver is in the right place.
If the fan speed is shifted in low or if the
shift is under FAN mode.
If the setting temperature is appropriate.
If the air- conditioner is found any failures as mentioned below, please turn off the power
immediately. Then contact the local dealer.
ON/OFF operation is not valid.
Fuse or leakage protector frequently blown.
Some matter or water falls into the unit.
Still no operation after checking the protector(P4).
Quite different from other indoor unit or ordinary
state.
13
Page 16
The Klimaire logo is a registered Trademark of Klimaire Products inc.
Copyright 2010 Klimaire Products Inc.
2190 NW 89 Place, Doral, FL 33172 - USA
Tel: (305)594-4972 Fax (305) 675-2212
www.klimaire.com sales@klimaire.com
The design and specifications are subject to change without prior notice for product
improvement. Consult with the sales agency or manufacturer for details.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.