Read, understand, and follow these instructions to ensure safe
operation. Failure to observe these warnings can result in risk of
fire, electric shock, serious injury and/or property damage.
•
DO NOT use the product if it is damaged or modified. Damaged
or modified batteries may exhibit unpredictable behavior
resulting in fire, explosion, or injury.
•
Risk of fire and burns. DO NOT open, crush, heat above specified
maximum temperature or incinerate. Prolonged exposure to
direct sunlight can result in elevated temperatures
•
DO NOT immerse in water or other liquids
•
Properly seal the charging port cover to achieve specified water
& foreign object ingress protection. Keep seal free of dirt, oil,
sand, or other material that interferes with proper sealing. Failure
to do so can result in risk of fire or electric shock.
•
DO NOT open the charging port cover if wet or in a wet
environment. Thoroughly dry the unit and the seal around waterresistant cover completely before opening water resistant cover
•
DO NOT subject to impacts or drops greater than 6.6' (2 m).
Drops larger than this may not show signs of damage, but
internal components may have been compromised. It is
advisable to replace the unit if any such severe events occur
•
Per CSA C22.2 60335-1. This appliance is not intended for use
by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not
play with the appliance.
•
DO NOT exceed rated charging values.
•
DO NOT attempt to repair the product or charging cable. There
are no user-serviceable parts.
MAINTENANCE
CLEANING: Be sure device disconnected from all power sources and
devices. Use clean, dry, soft, lint-free cloth to wipe down the entire
unit.
Do not use abrasive cleaners or solvents.
STORAGE: If storing for more than 1 month, charge completely
before storage, and recharge approximately every 3 months to avoid
full discharge. Store in cool temperatures, mild humidity, and away
from direct sunlight (See GENERAL SPECIFICATIONS). Leaving
in a vehicle or other confined spaces in extreme hot temperatures
can lead to decrease in service life, overheating, or fire. Extreme
cold temperatures below the specified storage range can also harm
performance and service life. Keep away from corrosive chemicals
and gases. After taking out of storage, inspect visually to make sure
device and all accessories look satisfactory. Allow unit to return to
ambient conditions before recharging or charging other devices.
RECHARGING: Recharge as needed. There are no pre-designated
intervals at which to recharge as long as you are using the unit
regularly. Avoid discharging completely on a regular basis, as this
can impact overall life. Regularly inspect ports and charging cable
for any debris, dirt, damage, and corrosion. DO NOT attempt to fix.
Replace device and/or cable as needed.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with
local regulations. Please see www.epa.gov/recycle for
additional information.
IP54 Ingress Protection Rating
Independently tested by Intertek and meets
applicable standards
Energy efciency veried
OPERATING INSTRUCTIONS
Read these instructions carefully before operating and keep for
future reference.
CHARGING BATTERY
•
Connect USB-C cable connection to the fan, plug the other
end of cable into USB (2.0 or higher) port, or AC adapter
(not included). USB adapter/power supply should not
exceed the specified charging voltage and current
(Max. 5.0V DC, 2.4A).
•
The battery level indicator bars will illuminate
(see TABLE 1 below):
•
4 bars solid (Red, Yellow, 2 Green solid): 100% charge
•
Red solid, yellow solid, one green solid: 75% to 99% charge
•
Red solid, yellow solid, one green blinking: 50% to 74% charge
•
Red solid, yellow blinking: 25% to 49% charge
•
Red blinking: 0% to 24% charge
•
A full charge could take up to 6 hours, depending on the
charger’s output. Charge completely before using. To
maximize battery life, see MAINTENANCE section (other side).
•
To check the battery level, press and hold the power button
for 5 seconds. The battery level will illuminate without
changing the speed of the fan
Red solid, yellow solid, one green
solid, one green blinking
Red solid, yellow solid, one green
blinking
Red solid, yellow blinking
Red blinking
No LEDs illuminated
75% to 99%
charge remaining
50% to 74%
charge remaining
25% to 49%
charge remaining
0% to 24%
charge remaining
0% charge remaining,
recharging required
USING THE FAN
Pressing the power button will show battery level, releasing
the button will turn on the fan:
•
Press and release once to turn the fan on HIGH
•
Press and release a second time to turn the fan on LOW
•
Press and release a third time to turn the fan OFF
NOTE: When charging the fan, the unit will operate at
LOW speed only.
MOUNTING OPTIONS
•
Clamp – open the clamp by squeezing the handles together.
Open the clamp fully and push as far onto the intended
object before releasing the clamp. The rubberized texture
inside the clamp provides better grip to materials including
conduit.
•
Magnets – four magnets can be placed onto any ferrous
surface. For best results, mount the fan with two farthest
magnets aligned vertically.
•
Nail hole – place the hole over the nail head and slide into
the slot for secure mounting.
TROUBLESHOOTING
PJSFM2 will NOT recharge IF:
•
The cable is not properly connected to charger output or
battery input. Check connection.
•
The charging cable is damaged. Replace with equivalent
cable.
•
The charging port or device is not able to supply the
minimum voltage and current for charging. Connect to
appropriate charging source.
•
The connector on the charger is damaged. Replace charger.
FIG. B
1370848 Rev 12/21 A
5014132
Capacity: 6400mAh (46.08Wh)
Input: 5V 2.4A, 12W
1370849 Rev 9/16/22 A
EP5015436
Conforms to UL Std. 507
Certied to CSA Std. C22.2
# 60335-1 & # 60335-2-80