GENERAL SPECIFICATIONS
• Cell Type: 18650 Lithium-ion
• Capacity: 6400mAh (46.08 Wh)
• Operating/Storage Altitude: 6562' (2000 m)
• Operating Temperature: 14° to 104°F (-10° to 40°C)
• Storage Temperature: -4° to 113°F (-20° to 45°C)
(up to 3 months)
Storage Humidity: <75% Relative humidity
• Charging Temperature: 32° to 104°F (0° to 40°C)
(For optimum charging, ambient temperature should be below 86°F (30°C))
• Operating/Charging Humidity: <85% non-condensing
• Runtime (minimum): High 5 hours, Low 12 Hour Charging Time: Full charge in 6 hours under optimum
charging conditions
Life Expectancy: Up to 500 charging cycles typical
(depending on use & care)
• Charging Requirements: Max 5V DC, 0.5A-2.4A (12W Max) Dimensions: 12.9" × 10.4" × 5.4" (327.7 × 264.2 × 137.2 mm)
Weight: 3.93 lb (1782 g)
• Drop Protection: 6.6' (2.0 m) Ingress Protection Rating: IP54
• Standards: UL 507, CSA C22.2 #60335-1, #60335-2-80,
UL2054, IEC62133, CE, UKCA, DOE/CEC, NRCan
Specifications subject to change.
Rechargeable Jobsite Fan
PJSFM2
–
Instructions
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
WARNINGS
Read, understand, and follow these instructions to ensure safe operation. Failure to observe these warnings can result in risk of fire, electric shock, serious injury and/or property damage.
•
DO NOT use the product if it is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion, or injury.
•
Risk of fire and burns. DO NOT open, crush, heat above specified maximum temperature or incinerate. Prolonged exposure to direct sunlight can result in elevated temperatures
•
DO NOT immerse in water or other liquids
•
Properly seal the charging port cover to achieve specified water & foreign object ingress protection. Keep seal free of dirt, oil, sand, or other material that interferes with proper sealing. Failure to do so can result in risk of fire or electric shock.
•
DO NOT open the charging port cover if wet or in a wet environment. Thoroughly dry the unit and the seal around water­resistant cover completely before opening water resistant cover
•
DO NOT subject to impacts or drops greater than 6.6' (2 m). Drops larger than this may not show signs of damage, but internal components may have been compromised. It is advisable to replace the unit if any such severe events occur
•
Per CSA C22.2 60335-1. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
•
DO NOT exceed rated charging values.
•
DO NOT attempt to repair the product or charging cable. There are no user-serviceable parts.
MAINTENANCE
CLEANING: Be sure device disconnected from all power sources and
devices. Use clean, dry, soft, lint-free cloth to wipe down the entire unit.
Do not use abrasive cleaners or solvents.
STORAGE: If storing for more than 1 month, charge completely
before storage, and recharge approximately every 3 months to avoid full discharge. Store in cool temperatures, mild humidity, and away from direct sunlight (See GENERAL SPECIFICATIONS). Leaving in a vehicle or other confined spaces in extreme hot temperatures can lead to decrease in service life, overheating, or fire. Extreme cold temperatures below the specified storage range can also harm performance and service life. Keep away from corrosive chemicals and gases. After taking out of storage, inspect visually to make sure device and all accessories look satisfactory. Allow unit to return to ambient conditions before recharging or charging other devices.
RECHARGING: Recharge as needed. There are no pre-designated intervals at which to recharge as long as you are using the unit regularly. Avoid discharging completely on a regular basis, as this can impact overall life. Regularly inspect ports and charging cable for any debris, dirt, damage, and corrosion. DO NOT attempt to fix. Replace device and/or cable as needed.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. Please see www.epa.gov/recycle for additional information.
OPERATING INSTRUCTIONS
PLEASE SEE REVERSE SIDE.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
ENGLISH
FEATURE DETAILS (FIG.A)
1
Fan blades
2
Fan cage
3
Fan cage arms Clamp
4
(with rubberized grip)
5
Handle
6
Power button
SYMBOLS ON PRODUCT (FIG.B)
Warning or Caution
Risk of Electrical Shock
Read Instructions
Conforms with European Economic Area directives Conforms with United Kingdom Conformity
Assessment Requirements WEEE: Electronics disposal
Magnet
IP54 Ingress Protection Rating Independently tested by Intertek and meets
applicable standards Energy efciency veried
OPERATING INSTRUCTIONS
Read these instructions carefully before operating and keep for future reference.
CHARGING BATTERY
Connect USB-C cable connection to the fan, plug the other end of cable into USB (2.0 or higher) port, or AC adapter (not included). USB adapter/power supply should not exceed the specified charging voltage and current (Max. 5.0V DC, 2.4A).
The battery level indicator bars will illuminate (see TABLE 1 below):
•
4 bars solid (Red, Yellow, 2 Green solid): 100% charge
•
Red solid, yellow solid, one green solid: 75% to 99% charge
•
Red solid, yellow solid, one green blinking: 50% to 74% charge
•
Red solid, yellow blinking: 25% to 49% charge
•
Red blinking: 0% to 24% charge
•
A full charge could take up to 6 hours, depending on the charger’s output. Charge completely before using. To maximize battery life, see MAINTENANCE section (other side).
To check the battery level, press and hold the power button for 5 seconds. The battery level will illuminate without changing the speed of the fan
7
Battery status indicator
8
Charging port cover
9
USB-C input
10
#10D Nail Hole
11
Magnets (x4)
FIG. A
1
2
3
4
5
6
7
9
8
1110
FIG. B
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
TABLE 1
Not Illuminated Green Yellow Red Blinking
LED
Status % Charged
4 bars solid (Red, Yellow, 2 Green solid)
100% charge remaining
Red solid, yellow solid, one green solid, one green blinking
Red solid, yellow solid, one green blinking
Red solid, yellow blinking
Red blinking
No LEDs illuminated
75% to 99% charge remaining
50% to 74% charge remaining
25% to 49% charge remaining
0% to 24% charge remaining
0% charge remaining, recharging required
USING THE FAN
Pressing the power button will show battery level, releasing the button will turn on the fan:
Press and release once to turn the fan on HIGH
Press and release a second time to turn the fan on LOW
Press and release a third time to turn the fan OFF
NOTE: When charging the fan, the unit will operate at
LOW speed only.
MOUNTING OPTIONS
Clamp – open the clamp by squeezing the handles together. Open the clamp fully and push as far onto the intended object before releasing the clamp. The rubberized texture inside the clamp provides better grip to materials including conduit.
Magnets – four magnets can be placed onto any ferrous surface. For best results, mount the fan with two farthest magnets aligned vertically.
Nail hole – place the hole over the nail head and slide into the slot for secure mounting.
TROUBLESHOOTING
PJSFM2 will NOT recharge IF:
The cable is not properly connected to charger output or battery input. Check connection.
The charging cable is damaged. Replace with equivalent cable.
The charging port or device is not able to supply the minimum voltage and current for charging. Connect to appropriate charging source.
The connector on the charger is damaged. Replace charger.
FIG. B
1370848 Rev 12/21 A
5014132
Capacity: 6400mAh (46.08Wh) Input: 5V 2.4A, 12W
1370849 Rev 9/16/22 A
EP5015436
Conforms to UL Std. 507 Certied to CSA Std. C22.2 # 60335-1 & # 60335-2-80
FCC & IC COMPLIANCE
See this product’s page for FCC compliance
information.
Canada ICES-003 (B) / NMB-003 (B)
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...