Klein Tools MM300 Instruction Manual

Dwg Name: MM300-1390109ART Dwg No: 1390109 ECO No: 20617 Rev: E Pkg Dwg Ref: 1290186 Color Reference: N/A
INSTRUCTION MANUAL
ENGLISH
10A
Ω
• DATA HOLD
• AUDIBLE CONTINUITY
• BATTERY TEST
• DIODE TEST
FRANÇAIS pg. 25
ESPAÑOL pg. 13
Manual-Ranging Digital Multimeter
MM300-1390109ART.indd 1 9/21/2015 2:48:00 PM
Dwg Name: MM300-1390109ART Dwg No: 1390109 ECO No: 20617 Rev: E Pkg Dwg Ref: 1290186 Color Reference: N/A
2
GENERAL SPECIFICATIONS
Klein Tools MM300 is a manual ranging multimeter that measures AC/DC voltage, DC current, and resistance. It can also test batteries, diodes, and continuity.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: 32°F to 104°F (0°F to 40°C)
• Storage Temp: 14°C to 140°F (-10°C to 60°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefcient: 0.1 x (Quoted Accuracy) per °C above
28°C or below 18°C, corrections are required when ambient working temp is outside of Accuracy Temp range
• Dimensions: 6.04" x 3.07" x 1.78" (153.4 x 78.0 x 45.2 mm)
• Weight: 8.1 oz. (230 g)
• Calibration: Accurate for one year
• Standards: Conforms to: UL STD 61010-1, 61010-2-030,
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1, 61010-2-030, 61010-2-033.
IEC EN 61010-1, 61010-2-030, 61010-2-033, 61326-1.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 3.3 ft. (1m)
• Safety Rating: CAT III 600V, Class 2, Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the building’s low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled electromagnetic environments like residential properties, business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
MM300-1390109ART.indd 2 9/21/2015 2:48:00 PM
Dwg Name: MM300-1390109ART Dwg No: 1390109 ECO No: 20617 Rev: E Pkg Dwg Ref: 1290186 Color Reference: N/A
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
DC Voltage
(V DC)
200.0mV 0.1mV
±(0.5% + 3 digits)2000mV 1mV
20.00V 0.01V
200.0V 0.1V ±(0.8% + 3 digits)
600V 1V
AC Voltage
(V AC)
200.0V 0.1V
±(1.2% + 10 digits)
50 to 60Hz
600V 1V
DC Current
(A DC)
200.0μA 0.1μA ±(1.0% + 5 digits)
20.00mA 10μA
200.0mA 100μA ±(1.2% + 5 digits)
10.00A 10mA ±(3.0% + 5 digits)
Resistance
200.0Ω 0.1Ω
±(1.0% + 5 digits)
2000Ω
20.00kΩ 0.01kΩ
200.0kΩ 0.1kΩ
2000kΩ 1kΩ ±(1.5% + 5 digits)
Battery Test
9V 10mV ±(1.0% + 2 digits)
1.5V 10mV ±(1.0% + 2 digits)
Diode Test: Approx. 1mA, open circuit voltage 2.0V DC
Continuity Check: Audible signal <100Ω
Battery Test: 9V (6mA); 1.5V (100mA)
Sampling Frequency: 2 samples per second
Overload: "OL" indicated on display, overload protection
600V RMS in all settings
Polarity: "-" on display indicates negative polarity
Display: 3 ½ digit, 2000 Count LCD
MM300-1390109ART.indd 3 9/21/2015 2:48:00 PM
Dwg Name: MM300-1390109ART Dwg No: 1390109 ECO No: 20617 Rev: E Pkg Dwg Ref: 1290186 Color Reference: N/A
4
WARNINGS
To ensure safe operation and service of the meter, follow these instructions. Failure to observe these warnings can result in severe injury or death.
• Before each use verify meter operation by measuring a known voltage or current.
• Never use the meter on a circuit with voltages that exceed the category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Use only with CAT III or CAT IV rated test leads.
• Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes are connected.
• Use caution when working with voltages above 25V AC RMS or 60V DC. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace batteries when a low battery indicator appears.
• Do not attempt to measure resistance or continuity on a live circuit.
• Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
SYMBOLS ON METER
AC (Alternating Current) DC (Direct Current)
Resistance (in Ohms) Ground
Diode Audible Continuity
Fuse (with rating below symbol) Double Insulated Class II
Warning or Caution
To ensure safe operation and service of this meter, follow all warnings and instructions detailed in this manual.
Risk of Electrical Shock
Improper use of this meter can lead to risk of electrical shock. Follow all warnings and instructions detailed in this manual.
SYMBOLS ON LCD