The Klein Tools MM2000 is a True RMS, auto-ranging multimeter.
2000 m
<
75%
0°C / 32°F to 40°C / 104°F
-20°C / -4°F to 60°C / 140°F
<
80% R.H.
18°C / 64°F to 28°C / 82°F
0.1*(specifi ed accuracy) / °C
7" x 3.5" x 1.875"
14 oz.
CAT III 1000V, CAT IV 600V
± (% of reading + # of least signifi cant digits)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
a known voltage or current.
category based rating of this meter.
the metal probe contacts when making measurements.
are connected.
To avoid false readings that can lead to electrical shock,
Always adhere to local and national safety codes. Use individual
Operating Altitude: Relative Humidity: Operating Temperature: Storage Temperature: Accuracy Temperature: Temperature Coeffi cient: Sampling Frequency Dimensions: Weight: Calibration CAT Rating: Accuracy:
AC Alternating Current Warning or Caution
DC Direct Current Double Insulated Class II
DC/AC Voltage or Current AC Source
Ground
AC Measurement DC Measurement
AT
Apo
AX
V
A
J
A
A. B. C.
Use CAT III / CAT IV rated leads.
A. Do not attempt to measure more than 1000V.
A. Do not attempt to measure more than 600V on
)
setting.
Negative DC Value Overload: Range Exceeded Low Battery
Minimum Reading
Auto Range Active Auto Power-Off Active
HOLD
Hold Active
Maximum Reading
Duty Cycle Mode Frequency Mode
Voltage Measurement
Current in Amps Low Impedance Mode Relative Reading Resistance in Ohms Diode Test Capacitance in Farads Continuity Test Degrees Fahrenheit
-9
Nano 10
-3
Milli 10
6
Mega 10
Apo
AT
Degrees Celsius
Micro 10
3
Kilo 10
MM2000
V
-6
0 10 20 4030
HOLD
MAX/MIN
RANGE
REL
SELECT
Duty
DTEK
Low Z
ºF º
C
m
Temp
m
COM
5
Turn the dial or press a button to wake.
,
, and
and
%
°F
and
°C
stored and live readings.
AT
is displayed on LCD only during auto ranging mode.
values will be saved while in this mode.
and minimum readings.
clear the stored maximum and minimum values.
J. K. Battery / Fuse Replacement
When
indicator is displayed on the LCD,
This meter uses 440mA / 1000V and 11A / 1000V fast blow fuses.
Attach instrument to metal for hands-free use.
The bar graph shows an approximate analog representation
The bar graph responds much faster than the digital display.
The scale of the bar graph is zero to the maximum reading of
the selected range.
Duty
DTEK
Low Z
ºF º
C
4
m
1
1
6
3
2
ºF º
C
Low Z
DTEK
1. AC / DC Voltage:
<
1000V,
)
) mode at voltages greater than 600V.
) mode to reduce ghost voltages
Attach red lead to “
A
2. AC / DC Current (large):
<
10A
3. AC / DC Current (small):
<
400mA
Attach red lead to “
4. Resistance / Capacitance / Diode / Continuity
<
4000µF
Safely discharge capacitor before measurement.
for large capacitors.
measure resistance
<
40M
Duty
C
Duty
ºF º
C
Low Z
DTEK
Duty
ºF º
C
Low Z
DTEK
ºF º
C
Low Z
DTEK
Low Z
REL HOLD MAX/MINRANGE
PRESS
m
COM
Low Z
Low Z
SELECT
COM
REL HOLD MAX/MINRANGE
ºF º
C
PRESS
m
m
m
COM
REL HOLD MAX/MINRANGE
ºF º
C
Duty
m
Low Z
DTEK
ºF º
PRESS
TO SELECT
Resistance
m
m
COM
PRESS
Capacitance
Diode
Continuity
m
HOLD MAX/MINRANGE
REL
ºF º
C
m
HOLD
COM
m
COM
HOLD MIN/MAX
ENGLISH
HOLD
MIN/MAX
Low Z
DTEK
5. Frequency (Hz) / Duty Cycle
<
1MHz
6. Temperature
apply voltage to thermocouple.
400mV ~ 400V
0.1mV
0.1V
± (0.5% + 4 digits)
±( 0.8% + 10 digits)
1000V
>
10M
<
100pF
> 3k
AC Voltage Measurement
400mV
0.1mV
± (0.75% + 5 digits)
± (2.5% + 10 digits)
4V ~ 400V
± (2.0% + 8 digits)
± (0.75% + 8 digits)
± (2.0% + 8 digits)*
1000V RMS
>
10M
<
100pF
>
3k
<
200pF, up to 600V RMS
40Hz ~ 20kHz
True RMS
C
°F °C
DTEK
C
ºF º
C
REL
RANGE
HOLD
MIN/MAX
PRESS
Testing Fuses
COM
SELECT
Duty
m
HOLD MAX/MIN
HOLD
Low Z
DTEK
PRESS
ºF º
m
m
COM
Hz Duty
Duty
SELECT
HOLD MAX/MIN REL
DTEK
Low Z
ºF º
C
Duty
PRESS
ºF º
ºF º
C
Duty
m
m
COM
m
m
COM
Range Resolution Accuracy
Overload Protection:
nput Impedance (Nominal):
Input Impedance (Low-Z):
Accuracy
Range Resolution 40Hz ~ 400Hz 400Hz ~ 20kHz
Overload Protection: Input Impedance (Nominal): Input Impedance (Low-Z): Frequency Response: Response:
Range Resolution Accuracy
400µA ~ 400mA
0.1µA
0.1mA
± (1.0% + 5 digits)
4A ~ 10A
10mA
± (1.5% + 5 digits)
400mA (F 440mA / 1000V fuse)
AC Current Measurement
400
A ~ 400mA
0.1
0.1mA
± (1.2% + 5 digits)
± (2.0% + 5 digits)
4A ~ 10A
10mA
± (1.8% + 5 digits)
± (2.5% + 10 digits)
400mA (F 440mA / 1000V fuse)
10A (F 11A / 1000V fuse)
40Hz to 10kHz
True RMS
400
~ 4M
0.1
0.001M
± (1.0% + 5 digits)
40M
0.01M
± (1.5% + 10 digits)
600V RMS
40nF
0.01nF
± (3.5% + 6 digits)
400nF ~ 4000µF
0.1nF
1µF
600V RMS
9.999Hz ~ 999.9kHz
0.001Hz
0.1kHz
± (0.1% + 3 digits)
600V RMS
0.7V RMS
0.1 ~ 99.9%
0.1%
± (0.2% per kHz + 0.1% + 5 digits)
600V RMS
0.5Hz to 100kHz, pulsewidth
>
2µsec
Temperature Measurement
-58 ~ 1832°F
0.1 ~ 1°F
± (3.0% + 5.4°F)
-50 ~ 1000°C
0.1 ~ 1°C
± (3.0% + 3.0°C)
600V RMS
Not specifi ed
Overload Protection:
uAmA Input:
A Input:
Accuracy
Range Resolution 40Hz ~ 400Hz 400Hz ~ 10kHz
Overload Protection:
uAmA Input:
A Input:
Frequency: Response:
Range Resolution Accuracy
Overload Protection:
Range Resolution Accuracy
Overload Protection:
Range Resolution Accuracy
Overload Protection: Sensitivity:
Range Resolution Accuracy
Overload Protection: Frequency Range:
Range Resolution Accuracy
Overload Protection: Thermocouple Accuracy:
1-877-775-5346
www.kleintools.com
450 Bond Street
Overload
600V RMS
0.25mA
<
1.6V DC
2.0V DC
600V RMS
Appx. 0.44V
WARRANTY
This product is warranted to be free from defects in materials and workmanship for a
conform to this warranty under normal use and service. This warranty does not cover dam-
age which occurs in shipment or failure which results from alteration, tampering, accident,
failed batteries are not covered by warranty. A purchase receipt or other proof of original
Any implied warranties, including but not limited to implied warranties of merchantability
and fi tness for a particular purpose, are limited to the express warranty. Klein Tools shall
expenses, or economic loss, or for any claim or claims for such damage, expenses or
economic loss.
Some states or countries laws vary, so the above limitations or exclusions may not apply
to you. This warranty gives you specifi c legal rights, and you may also have other rights
which vary from state to state. If your Klein product requires repair or for information on
Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth.
expose to high temperatures or humidity. After a period of storage in extreme conditions
exceeding the limits mentioned in the Specifi cations section, allow the instrument to return
to normal operating conditions before using it.
This symbol indicates that equipment and its accessories shall
Protection
Test Current (Typical)
Open Circuit Voltage
Overload Protection Open Circuit Voltage
Range
Caution:
www.kleintools.com
Apo
VALOR EFICAZ
VERDADERO
AUTO / MANUAL
AT
0 10 20 4030
MAX/MIN
RANGE
REL
SELECT
Duty
m
DTEK
Low Z
ºF º
COM
MM2000
V
HOLD
C
m
Temp
®
TRMS
Para Profesionales... Desde 1857
ESPAÑOL
tensión de baja impedancia, corriente CA / CC, resistencia, capacitancia,
frecuencia, ciclo de servicio y temperatura. También puede probar diodos
y continuidad.
2000 m
<
75%
0°C / 32°F a 40°C / 104°F
-20°C / -4°F a 60°C / 140°F
<
80% H.R.
18°C / 64°F a 28°C / 82°F
0,1*(precisión especifi cada) / °C
3 muestras por segundo
7 x 3,5 x 1,875 pulgadas
14 onzas
Precisa durante un año
CAT III 1000V, CAT IV 600V
± (% de la lectura + No. de dígitos menos signifi cativos)
ADVERTENCIAS
estas instrucciones. Si no se hace caso de estas advertencias, el resultado
Antes de cada uso, verifi que el funcionamiento del multímetro midiendo
dañados.
Asegúrese de que los conductores de prueba del multímetro estén
completamente asentados y mantenga los dedos alejados de los contactos
de prueba estén conectados.
Tenga precaución cuando trabaje con tensiones superiores a 60 V CC, o 25 V
CA de valor efi caz (RMS). Dichas tensiones presentan un peligro de descarga.
A menos que mida tensión o corriente, apague y bloquee el suministro
eléctrico antes de medir resistencia o capacitancia.
Cumpla siempre con los códigos de seguridad locales y nacionales.
y las lesiones por intensas corrientes de arco donde los conductores con
corriente peligrosos estén al descubierto.
Altitud de funcionamiento: Humedad relativa: Temperatura de funcionamiento: Temperatura de almacenamiento: Temperatura de precisión: Coefi ciente de temperatura: Frecuencia de muestreo: Dimensiones: Peso: Calibración: Califi cación CAT: Precisión:
CA Corriente alterna Advertencia o precaución
CC Corriente continua
Con aislamiento doble de Clase II
Tensión o corriente CC/CA Fuente de CA
Conexión a tierra
Medición de CA Medición de CC
AT
Apo
AX
V
A
J
A
A. B. C.
A. No intente medir más de 1000 V
A.
Valor de CC negativo
Sobrecarga: Intervalo excedido Pila baja
Lectura mínima
Determinación automática del intervalo activa
Autoapagado activo
HOLD
Retener en activo
Lectura máxima
Modo de ciclo de servicio Modo de frecuencia
Medición de tensión
Corriente en A Modo de baja impedancia Lectura relativa Resistencia en ohmios Prueba de diodo Capacitancia en faradios Prueba de continuidad Grados Fahrenheit
-9
Nano 10
-3
Mili 10
6
Mega 10
Apo
AT
Grados centígrados
Micro 10
Kilo 10
MM2000
V
-6
3
0 10 20 4030
RANGE
REL
SELECT
Duty
m
Low Z
DTEK
MAX/MIN
ºF º
COM
HOLD
C
m
Temp
5
Si se mantiene presionado el botón Select mientras se enciende
,
, y
.
y
%
°F
y
°C
automática del intervalo.
AT
se muestra en la pantalla de LCD solamente durante el modo de
determinación automática del intervalo.
eliminar los valores máximo y mínimo almacenados.
J. K. Reemplazo de las pilas y los fusibles
se muestre en la pantalla de LCD,
440 mA / 1000 V y 11 A / 1000 V.
Sujete el instrumento a metal para permitir su uso con las manos libres.
de una medición.
Duty
DTEK
Low Z
ºF º
C
4
m
1
1
6
3
2
ºF º
C
Low Z
DTEK
1. Tensión de CA / CC:
<
1000V,
)
(
)
a tensiones superiores a 600 V.
)
Comience con este ajuste si el nivel de corriente es desconocido.
Conecte el conductor de prueba rojo a la entrada “
A
Seleccione la fuente de corriente CA o CC.
2. Corriente CA / CC (grande):
<
10A
3. Corriente CA / CC (pequeña):
<
400mA
Conecte el conductor de prueba rojo a la entrada de “
Seleccione µA o mA, y la fuente de corriente CA o CC.
4. Resistencia / Capacitancia / Diodo / Continuidad
<
4000µF
Descargue de manera segura el capacitor
antes de realizar la medición.
en el caso de capacitores grandes.
No mida resistencia en un circuito
<
40M
Duty
C
Duty
ºF º
C
Low Z
DTEK
Duty
ºF º
C
Low Z
DTEK
ºF º
C
Low Z
Caída de tensión en sentido directo si la
DTEK
Low Z
REL HOLD MAX/MINRANGE
PRESIONE
COM
CA CC
m
Low Z
SELECT
Low Z
Low Z
Low Z
ºF º
C
PRESIONE
m
m
m
COM
CA CC
REL HOLD MAX/MINRANGE
REL HOLD MAX/MINRANGE
ºF º
C
m
PRESIONE
m
m
COM
CA CC
ºF º
HOLD MAX/MINRANGE
PARA SELECCIONAR
Resistencia Capacitancia
Diodo Continuidad
PRESIONE
REL
DTEK
Low Z
Duty
ºF º
C
m
COM
m
COM
m
COM
HOLD
HOLD MIN/MAX
ESPAÑOL
º º
HOLD
MIN/MAX
Low Z
DTEK
5. Frecuencia (Hz) / Ciclo de servicio < 1MHz
6. Temperatura
aplique tensión al termopar.
400mV ~ 400V
0.1mV
0.1V
± (0.5% + 4 dígitos)
±( 0.8% + 10 dígitos)
1000V
>
10M
<
100pF
> 3k
400mV
0.1mV
± (0.75% + 5 dígitos)
± (2.5% + 10 dígitos)
4V ~ 400V
± (2.0% + 8 dígitos)
± (0.75% + 8 dígitos)
± (2.0% + 8 dígitos)*
1000V (RMS)
>
10M
<
100pF
>
3k
< 200 pF, hasta 600 V de valor efi caz (RMS)
40Hz ~ 20kHz
Valor efi caz (RMS) verdadero
C
DTEK
C
ºF º
C
REL
RANGE
HOLD
MIN/MAX
m
COM
HOLD MAX/MIN
SELECT
Duty
SELECT
Duty
Low Z
Duty
DTEK
HOLD
DTEK
Low Z
ºF º
Hz Duty
HOLD MAX/MIN REL
PRESIONE
ºF º
C
ºF º
PRESIONE
°F °C
PRESIONE
Low Z
ºF º
C
Duty
m
m
COM
ºF º
C
Duty
m
m
COM
m
m
COM
Intervalo Resolución Precisión
Protección contra sobrecargas:
Impedancia de entrada (nominal):
Impedancia de entrada (baja, Low Z):
Precisión
Intervalo Resolución 40Hz ~ 400Hz 400Hz ~ 20kHz
Protección contra sobrecargas: Impedancia de entrada (nominal): Impedancia de entrada (baja, Low Z): Intervalo de frecuencia: Respuesta:
Intervalo Resolución Precisión
400µA ~ 400mA
0.1µA
0.1mA
± (1.0% + 5 dígitos)
4A ~ 10A
10mA
± (1.5% + 5 dígitos)
400mA (fusible F 440 mA / 1000 V)
400
A ~ 400mA
0.1
0.1mA
± (1.2% + 5
)
± (2.0% + 5
)
4A ~ 10A
10mA
± (1.8% + 5
)
± (2.5% + 10
)
400 mA (fusible F 440 mA / 1000 V)
10A 10 A (F 11 A / 1000 V)
40Hz a 10kHz
Valor efi caz (RMS) verdadero
400
~ 4M
0.1
0.001M
± (1.0% + 5 dígitos)
40M
0.01M
± (1.5% + 10 dígitos)
600V (RMS)
40nF
0.01nF
± (3.5% + 6 dígitos)
400nF ~ 4000µF
0.1nF
1µF
600V (RMS)
9.999Hz ~ 999.9kHz
0.001Hz
0.1kHz
± (0.1% + 3 dígitos)
600V (RMS)
0.7V (RMS)
0.1 ~ 99.9%
0.1%
± (0.2% por kHz + 0.1% + 5 dígitos)
600V (RMS)
0.5Hz a 100kHz, amplitud de pulso> 2µsec
-58 ~ 1832°F
0.1 ~ 1°F
± (3.0% + 5.4°F)
-50 ~ 1000°C
0.1 ~ 1°C
± (3.0% + 3.0°C)
600V (RMS)
No especifi cada
Protección contra sobrecargas:
Entrada de uAmA:
Entrada de A:
Precisión
Intervalo Resolución 40Hz ~ 400Hz 400Hz ~ 10kHz
Protección contra sobrecargas:
Entrada de uAmA:
Entrada de A:
Frecuencia: Respuesta:
Intervalo Resolución Precisión
Protección contra sobrecargas:
Intervalo Resolución Precisión
Protección contra sobrecargas:
Intervalo Resolución Precisión
Protección contra sobrecargas: Sensibilidad:
Intervalo Resolución Precisión
Protección contra sobrecargas: Intervalo de frecuencia:
Intervalo Resolución Precisión
Protección contra sobrecargas: Precisión del termopar:
450 Bond Street
1-877-775-5346
www.kleintools.com
Protección contra
600V (RMS)
0.25mA
<
1.6V CC
2.0V CC
600V (RMS)
Aprox. 0.44V
Se garantiza que este producto estará libre de defectos de materiales y fabricación durante un
Tools tiene la opción de reparar, reemplazar o reembolsar el precio de compra de cualquier
garantía. Se requerirá un recibo de compra u otro comprobante de la fecha de compra
original antes de que se realicen las reparaciones bajo garantía.
Todas las garantías implícitas, incluyendo pero sin estar limitadas a las garantías implícitas
de comerciabilidad e idoneidad para un propósito específi co, están limitadas a la garantía
expresa. Klein Tools no será responsable por la pérdida de uso del instrumento u otros daños
exclusiones que anteceden no tengan aplicación en el caso de usted. Esta garantía le confi ere
a usted derechos legales específi cos y es posible que usted tenga también otros derechos
que varían de un estado a otro. Si su producto Klein requiere reparación, o para obtener
contactar a Klein Tools llamando al 1-877-775-5346.
Apague el instrumento y desconecte los conductores de prueba. Limpie el instrumento
ALMACENAMIENTO
en condiciones extremas que excedan los límites mencionados en la sección Especifi caciones,
deje que el instrumento regrese a las condiciones de funcionamiento normales antes de
sujetos a recogida y desecho correcto por separado.
sobrecargas
Corriente de prueba (típica)
Tensión de circuito abiertoe
Intervalo
Protección contra sobrecargas
Tensión de circuito abierto
Precaución:
www.kleintools.com
Apo
VALEUR
À BARRES
3 3/4 CHIFFRES
AUTO / MANUEL
AT
0 10 20 4030
MAX/MIN
RANGE
REL
SELECT
Duty
m
DTEK
Low Z
ºF º
COM
MM2000
V
HOLD
C
m
Temp
®
TRMS
Pour les Professionnels...Depuis 1857
FRANÇAIS
tension à faible impédance, le courant électrique c.a. / c.c., la résistance,
également tester des diodes et la continuité des circuits.
2 000 m
<
75%
0°C / 32°F à 40°C / 104°F
-20°C / -4°F à 60°C / 140°F
<
80% H.R.
18°C / 64°F à 28°C / 82°F
0,1* (précision spécifi ée) / °C
3 échantillons par seconde
7 po x 3,5 po x 1,875 po
14 oz.
Précis pendant un an
CAT III 1000V, CAT IV 600V
± (% de lecture + nombre de chiffres les moins signifi catifs)
AVERTISSEMENTS
suivez les instructions ci-après. Le non-respect des ces avertissements
Avant chaque emploi, vérifi ez le fonctionnement de l’appareil de mesure en
qualifi cation de catégorie de cet appareil de mesure.
endommagés.
Assurez-vous que les fi ls de connexion de l’appareil de mesure sont bien à leur
vous effectuez des mesures.
sondes sont toujours connectées.
60 V c.c. ou 25 V c.a. eff. De telles tensions présentent un risque de choc
électrique.
Sauf si vous êtes en train de mesurer une tension ou un courant, mettez
capacité.
choc électrique ou de blessure causée par une explosion électrique lorsque des
conducteurs sous tension dangereux sont exposés.
Altitude de service : Humidité relative : Température de service : Température de stockage : Précision en température : Coeffi cient de température : Fréquence d’échantillonnage : Dimensions : Poids : Étalonnage : Qualifi cation de cat. : Précision :
Courant alternatif c.a.
Avertissement ou Mise en garde
Courant continu c.c. Classe II, double isolation Tension ou courant c.c./c.a. Source c.a. Masse
Mesure c.a. Mesure c.c.
AT
Apo
A. B. C.
Utilisez des fi ls CAT. III / CAT. IV (valeur nominale).
A.
A. Ne tentez pas de mesures plus de 600 V sur un réglage (bas).
supérieure à 400 mA.
supérieure à 10 A.
Tournez le cadran ou appuyez sur un bouton pour réactiver l’appareil.
de l’appareil désactive la fonction de mise hors tension automatiquement (Apo).
J
Valeur c.c. négative Surcharge :
Limite de plage dépassée Décharge partielle des piles
Lecture minimum
Plage automatique activée Fonction de Mise hors tension
automatiquement active
HOLD
Maintien en position activée
Lecture maximum Mode de cycle de service Mode de fréquence Mesure de la tension
Courant en ampères Mode de faible impédance Lecture relative Résistance en Ohms Test de diode Capacité en Farads Test de continuité Degrés Fahrenheit
-9
Nano 10
-3
Milli 10
6
Méga 10
Apo
AT
0 10 20 4030
REL
SELECT
Duty
RANGE
Low Z
MAX/MIN
DTEK
ºF º
C
Degrés Celsius
Micro 10
Kilo 10
MM2000
V
HOLD
m
-6
3
Temp
m
COM
5
Commutation entre c.a. et c.c
Commutation entre
,
, et
.
Commutation entre
et
%
Commutation entre
°F
et
°C
Appuyez pour enregistrer la valeur actuelle.
et les valeurs actuelles.
Appuyez à nouveau pour retourner à la valeur actuelle.
Appuyez de façon répétée pour parcourir les plages manuelles.
Appuyez et maintenez enfoncé pendant deux secondes pour retourner
dans le mode de sélection automatique de plage.
AT
est affi ché sur l’écran ACL seulement dans le mode de sélection
automatique de plage.
Appuyez pour entrer dans le mode Max / Min ; les valeurs les plus grandes
et les plus petites seront enregistrées pendant que vous serez dans ce mode.
Appuyez de façon répétée pour alterner entre la lecture de la valeur maximum
et la lecture de la valeur minimum.
Appuyez et maintenez enfoncé pendant deux secondes pour retourner à la valeur
actuelle et effacer les valeurs max. et min. enregistrées alors.
Appuyez pour maintenir la valeur actuelle sur l’écran.
Appuyez à nouveau pour retourner à la valeur actuelle.
Appuyez et maintenez enfoncé pendant deux secondes
J. K. Remplacement des piles / du fusible
est affi ché sur l’écran ACL, cela signifi e qu’il faut
changer les piles.
et remplacez les 2 piles AAA.
Cet appareil utilise des fusibles à fusion rapide de 440 mA / 1 000 V
et de 11 A / 1 000 V.
Attachez l’instrument à une surface en métal afi n d’avoir les mains libres.
approximative d’une mesure.
que l’affi chage numérique.
dans la plage sélectionnée.
Duty
DTEK
Low Z
ºF º
C
4
m
1
1
6
3
2
ºF º
C
Low Z
DTEK
1. Tension c.a./c.c. :
<
1 000V,
Z bas
)
) à faible impédance pour réduire les tensions fantômes.
2. Courant c.a. / c.c. (fort) :
<
10A
3. Courant c.a. / c.c. (faible) :
<
400mA
4. Résistance / Capacité / Diode / Continuité
<
4 000µF
avant d’effectuer la mesure.
secondes dans le cas des grands condensateurs.
la résistance
sur un circuit sous tension.
<
40M
Low Z
Duty
C
Duty
ºF º
C
Low Z
DTEK
Duty
ºF º
C
Low Z
DTEK
º º
Low Z
DTEK
Low Z
REL HOLD MAX/MINRANGE
APPUYEZ
m
c.a. c.c.
m
COM
Low Z
SELECT
REL HOLD MAX/MINRANGE
ºF º
C
APPUYEZ
m
m
m
COM
c.a. c.c.
REL HOLD MAX/MINRANGE
ºF º
C
m
APPUYEZ
m
m
COM
c.a. c.c.
ºF º
HOLD MAX/MINRANGE
POUR SÉLECTIONNER
Résistance Capacité
Diode Continuité
APPUYEZ
REL
DTEK
Low Z
Duty
m
COM
F
m
HOLD
COM
m
COM
HOLD MIN/MAX
FRANÇAIS
HOLD
MIN/MAX
Low Z
DTEK
5. Fréquence (Hz) / Cycle de service < 1 MHz
6. Température
de tension au thermocouple.
est inférieure à 30
400mV ~ 400V
0.1mV
0.1V
± (0.5% + 4 chiffres)
±( 0.8% + 10 chiffres)
1000V
>
10M
<
100pF
> 3k
400mV
0.1mV
± (0.75% + 5 chiffres)
± (2.5% + 10 chiffres)
4V ~ 400V
± (2.0% + 8 chiffres)
± (0.75% + 8 chiffres)
± (2.0% + 8 chiffres)*
1 000V eff.
>
10M
<
100pF
>
3k
< 200 pF jusqu’à 600 V eff.
40Hz ~ 20kHz
Valeur effi cace vraie
C
DTEK
C
ºF º
C
REL
RANGE
HOLD
MIN/MAX
Test des fusibles
m
COM
HOLD MAX/MIN
SELECT
Duty
SELECT
Duty
Low Z
Duty
DTEK
Low Z
ºF º
DTEK
C
HOLD
APPUYEZ
ºF º
Hz Duty
HOLD MAX/MIN REL
APPUYEZ
°F °C
APPUYEZ
ºF º
Low Z
ºF º
C
Duty
m
m
COM
ºF º
C
Duty
m
m
COM
m
m
COM
Plage Résolution Précision
Protection contre les surcharges : Impédance d’entrée (nominale) : Impédance d'entrée (Z bas) :
Précision
Plage Résolution 40Hz ~ 400Hz 400Hz ~ 20kHz
Protection contre les surcharges : Impédance d’entrée (nominale) : Impédance d'entrée (Z bas) : Réponse en fréquence: Réponse :
Plage Résolution Précision
400µA ~ 400mA
0.1µA
0.1mA
± (1.0% + 5 chiffres)
4A ~ 10A
10mA
± (1.5% + 5 chiffres)
400 mA (fusible F 440 mA / 1 000 V)
400
A ~ 400mA
0.1
0.1mA
± (1.2% + 5 digits)
± (2.0% + 5
chiffres
)
4A ~ 10A
10mA
± (1.8% + 5 digits)
± (2.5% + 10
chiffres
)
400 mA (fusible F 440 mA / 1 000 V)
10 A (fusible F 11 A / 1 000 V)
40Hz à 10kHz
Valeur effi cace vraie
400
~ 4M
0.1
0.001M
± (1.0% + 5 chiffres)
40M
0.01M
± (1.5% + 10 chiffres)
600V eff.
40nF
0.01nF
± (3.5% + 6 chiffres)
400nF ~ 4 000µF
0.1nF
1µF
600V eff.
9.999Hz ~ 999.9kHz
0.001Hz
0.1kHz
± (0.1% + 3 chiffres)
600V eff.
0.7V eff.
0.1 ~ 99.9%
0.1%
± (0.2% par kHz + 0.1% + 5 chiffres)
600V eff.
0,5 Hz à 100 kHz, largeur d’impulsion > 2µsec
-58 ~ 1 832°F
0.1 ~ 1°F
± (3.0% + 5.4°F)
-50 ~ 1 000°C
0.1 ~ 1°C
± (3.0% + 3.0°C)
600V eff.
Non précisé
Protection contre les surcharges :
Entrée µAmA :
A Entrée :
Précision
Plage Résolution 40Hz ~ 400Hz 400Hz ~ 10kHz
Protection contre les surcharges :
Entrée µAmA :
A Entrée :
Fréquence : Réponse :
Plage Résolution Précision
Protection contre les surcharges :
Plage Résolution Précision
Protection contre les surcharges :
Plage Résolution Précision
Protection contre les surcharges : Sensibilité :
Plage Résolution Précision
Protection contre les surcharges : Plage de fréquences :
Plage Résolution Précision
Protection contre les surcharges : Précision du thermocouple :
1-877-775-5346
www.kleintools.com
450 Bond Street
Ce produit est garanti sans défauts de matériau ou de fabrication pendant une période de
deux ans à compter de la date de l’achat. Pendant cette période de garantie, à son choix,
des conditions normales d’utilisation et de service, ou en remboursera le prix d’achat.
Cette garantie ne couvre pas les dommages qui surviennent pendant l’expédition ou les
défaillances qui résultent d’une altération, d’une falsifi cation, d’un accident, d’une utilisation
dommages résultant de piles défectueuses ne sont pas couverts par la garantie. Un reçu
d’achat ou un autre justifi catif indiquant la date de l’achat initial sera exigé avant que des
Toutes garanties implicites, y compris, entre autres, les garanties implicites de qualité
ou accessoires, ou en cas de réclamation ou de réclamations pour de tels dommages,
frais ou pertes économiques.
varient, les limitations ou exclusions ci-dessus ne s’appliquent peut-être pas à vous.
Cette garantie vous confère des droits particuliers, et vous pouvez aussi avoir d’autres
droits qui varient selon l’État ou la province où vous résidez. Si votre produit Klein
des termes de la présente garantie, veuillez contacter Klein Tools au 1-877-775-5346.
tissu humide. N’utilisez pas de solvants ou de produits de nettoyage abrasifs.
section consacrée aux spécifi cations, laissez l'instrument retourner dans des conditions
de mesure normales avant de vous en servir à nouveau.
Ce symbole indique que l'équipement et ses accessoires
doivent faire l'objet d'une élimination distincte et d'une mise au rebut
conforme aux règlements.
Test de diode
Protection contre
600V eff.
0.25mA
<
1.6V c.c.
2.0V c.c.
Test de continuité
600V eff.
Appx. 0.44V
les surcharges
Courant de test (typique)
Tension de circuit ouvert
Plage
Protection contre les surcharges Tension de circuit ouvert
Mise en garde: