Page 6
6
INSTRUCTION ON MOUNTING AND USE GB
Consult the designs in the front pages referenced in the text by alphabet letters. Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined.
The rangehood must be placed at a minimum distance of 650mm from the cooking plane for electric, gas and mixed cooktops. Please confirm this measurement with your Local Building Authority.
The rangehood is equipped with a top air outlet "B“ for discharge of fumes to the outside (Ducting version – exhaust pipe and pipe fixing clamps not provided). Should it not be possible to discharge cooking fumes and vapour to the outside, the rangehood can be used in the filter version, fitting an activated carbon filter and the deflector "F“ on the support (bracket) "G“, fumes and vapours are recycled through the top grille "H“ by means of an exhaust pipe connected to the top air outlet "B“ and the connection ring mounted on the deflector "F“ (exhaust pipe and pipe fixing clamps not provided).
Installation - Fig. 5
Preliminary information for installation of the rangehood:
Disconnect the rangehood during electrical connection, by turning the home mains switch off. Expansion wall plugs are provided to secure the rangehood to most types of walls/ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the rangehood.
Do not tile, grout or silicone this appliance to the wall. Surface mounting only.
1. Using a pencil, draw a line on the wall, extending up to
the ceiling, to mark the centre. This will facilitate installation.
2. Rest the drilling template against the wall: the vertical centre line printed on the drilling template must correspond to the centre line drawn on the wall, and the bottom edge of the drilling template must correspond to the bottom edge of the rangehood: bear in mind that, when installation is complete, the underside of the rangehood must be at least 650mm above the cooktop in the case of electric, gas and mixed cooktops. Please confirm this measurement with your Local Building Authority.
3. Rest the support bracket on the drilling template so that it coincides with the dotted rectangle, mark the two outer holes and drill them, remove the drilling template, insert 2 wall plugs and fix the rangehood support bracket into place using two 5x45mm screws.
4. Hang the rangehood on the bracket.
5. Adjust the distance of the rangehood from the wall.
6. Adjust the horizontal position of the rangehood.
7. From inside the suction unit, use a pencil to mark the hole
to be used for final fixing of the rangehood.
8. Remove the rangehood from the bracket.
9. Drill at the point marked (Ø8mm - see operation 7).
10.Insert 1 wall plug
11.Rest the chimney support bracket
touching the ceiling. Use the support bracket as a drilling template (the small slot formed on the support must coincide with the line drawn on the wall as above – operation 4) and mark 2 holes with a pencil, drill the holes (Ø8mm), insert 2 wall plugs.
12.Fix the chimney support bracket to the wall using two 5x45mm screws.
13.Hook the rangehood onto the bottom bracket.
14.Fix the rangehood into its final position on the wall using
one 5x45mm screw (ABSOLUTELY ESSENTIAL).
15. Slide the lower part of the rangehood to suction group.
16. Connect the lamp connector to the suction group.
17.Fasten the rangehood to the suction unit using 4 screws.
18.Connect a pipe (pipe and pipe clamps not provided, to
be purchased separately) for discharge of fumes to the connection ring located over the suction motor unit. If the rangehood is to be used in ducting version, the other end of the pipe must be connected to a device expelling the fumes to the outside. If the rangehood is to be used in filter version, fix deflector
"G"
using 2 screws, and connect the other end of the pipe
to the connection ring on deflector
19.Make the electrical connections.
20.Apply the chimney stacks and fasten them at the top to
the chimney support convoy the lower section of the chimney flue downwards to avoid damaging either the rangehood or the chimney flue.
21.Raise the lower chimney section and thread the control panel cable via the perforation slit.
22. Allow the lower chimney section to slide downwards, insert the lower chimney border in the proper housing above the rangehood.
23.Connect the control panel cable.
24. Fix with a jolt the panel in the chimney flue perforation
THE LAMP BUTTON SHOULD BE LOCATED ON THE LOWER SIDE.
Remount the grease filter/s and check that the rangehood is operating perfectly. Otherwise check the connections of the control panel and/ or the electrical network.
Electrical connection
The electrical tension must correspond to the tension noted on the label placed inside the rangehood. Connect the electrical plug, where provided, to the an easily accessible outlet in conformity with local standards in force. Where an electrical plug is not provided (for direct connection to electrical network) place a standards approved bipolar switch with an aperture distance of not less than 3mm (accessible) from the contacts.
"F"
to the chimney support bracket
"G"
"G"
against the wall,
"F"
.
(20b) using 2 screws (20a),
Page 7
INSTRUCTION ON MOUNTING AND USEGB
7
Description of the rangehood - Fig. 1
1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp 5 Vapour screen 6 Telescopic chimney 7 Air outlet (used for filter version only)
Operation – Model with button panel
Description of control panel and rangehood operation
maximum power selection aspiration switch
medium power selection aspiration switch
on/off aspiration switch and minimum power selection
on/off light switch
Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the rangehood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking.
discolour slightly, but this does not affect its filtering capacity. To remove the grease filter, pull the spring release handle
"f“ - (Fig. 2).
Charcoal filter (filter version only)
It absorbs unpleasant odours caused by cooking. The charcoal filter can be washed once every two months using hot water and a suitable detergent, or in a dishwasher at 65°C (if the dishwasher is used, select the full cycle function and leave dishes out). Eliminate excess water without damaging the filter, then remove the mattress located inside the plastic frame and put it in the oven for 10 minutes at 100° C to dry completely. Replace the mattress every 3 years or when the cloth is damaged. Remove the filter holder frame by turning the knobs "g“ 90° that affix the chimney to the rangehood (Fig. 3). Insert the pad "i“ of activated carbon into the frame "h“ and fit the whole back into its housing "j“.
Replacing lamps - Fig. 4
Firstly check that the lamps are well cooled prior to replacing them. Use a small screwdriver as a lever on the borders of the lamp in order to remove the lightbulb. Unthread the connector Slide out the lightbulb to be replaced and replace with a new 12V 20W 30° Ø35 12V GU4 PHILIPS STANDARD LINE code
425409.
Carry out the replacement and mount the new lightbulb by following instructions in the reverse.
If the lights do not work, make sure that the lamps are fitted properly into their housings before you call for technical assistance.
"
A".
Maintenance
Prior to any maintenance operation ensure that the range hood is disconnected from the power supply.
Cleaning
The rangehood should be cleaned regularly internally and externally. For cleaning use a cloth moistened with denatured alcohol or neutral liquid detergents. Avoid abrasive detergents.
Warning:
Failure to carry out the basic standards of the cleaning of the rangehood and replacement of the filters may cause fire risks.
Therefore we recommend observing these instructions.
Grease filter
This must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may
Caution
This appliance is designed to be operated by adults. Children should not be allowed to tamper with the controls or play with the appliance. Do not use the rangehood where the grill is not correctly fixed! The suctioned air must not be conveyed in the same channel used for fumes discharged by appliances powered by other than electricity. The environment must always be adequately aerated when the rangehood and other appliances powered by other than electricity are used at the same time. Flambé cooking with a rangehood is prohibited. The use of a free flame is damaging to the filters and may cause fire accidents, therefore free flame cooking must be avoided. Frying of foods must be kept under close control in order to avoid overheated oil catching fire. Carry out fumes discharging in accordance with the regulations in force by local laws for safety and technical restrictions.