KJB CPM700 User Manual

CPM-700
COUNTERSURVEILLANCE PROBE/MONITOR
*
*
CPM-700 is available with several optional probes and accessories; some of which are pictured above. This manual addresses available probes and accessories with the CPM-700, however these probes and accessories are not necessarily included with each CPM-700.
PRECAUTION / WARNING!
The overall effectiveness of this product is directly dependent on your familiarization and level
of threat. This manual is marked * in areas where special attention is required.
RESEARCH ELECTRONICS INTERNATIONAL
455 Security Place
Algood, TN 38506 U.S.A.
+1 931-537-6032
http://www.reiusa.net/
Revision 2
© COPYRIGHT RESEARCH ELECTRONICS INTERNATIONAL
This manual contains proprietary information intended
solely for use with the CPM-700 and CPM-700 Probes and Accessories.
All information contained within this manual
is subject to change without notice.
OWNER’S RECORD
The Serial Number of your unit is located on the side panel. Please record this number and refer to it whenever you contact your dealer or Research Electronics International concerning this product. Note: Removal or alteration of the serial number automatically voids all warranties of this product.
MODEL: CPM-700
SERIAL NUMBER: __________________
RESEARCH ELECTRONICS INTERNATIONAL
455 Security Place
Algood, TN 38506 U.S.A.
+1 931-537-6032
www.reiusa.net
TABLE OF CONTENTS
TABLE OF CONTENTS
INTRODUCTION............................................................. 1
CPM-700 PACKAGES .............................................. 2
FEATURES OF THE CPM................................................... 5
POWER SUPPLIES, PROBES, ACCESSORIES .................. 5
FRONT PANEL FEATURES ......................................... 9
AUDIO GROUP ......................................................9
MONITOR GROUP.................................................. 9
DISPLAY GROUP .................................................. 10
PROBE GROUP .................................................... 11
SIDE PANEL FEATURES........................................... 11
POWER SOURCES......................................................... 13
ALKALINE BATTERY OPERATION .............................. 13
AC ADAPTER OPERATION ...................................... 13
OPTIONAL RECHARGEABLE BATTERY OPERATION....... 13
CHARGING INSTRUCTIONS ................................... 13
BASIC CPM-700 RF PROCEDURE.................................... 15
RF CONSIDERATIONS ........................................... 16
PERFORMING A “WALK AROUND ROOM SWEEP” ....... 16
DETAILED CPM-700 PROCEDURE................................... 19
METER CALIBRATION ............................................ 19
KNOWN SOUND SOURCE ..................................... 19
RF PROBE ANALYSIS ............................................. 20
BROADBAND RF ANALYSIS (2GHZ – 12GHZ) ............. 22
DETAILED INSPECTION SWEEP................................ 24
PHONE/LINE RF SWEEP ......................................... 25
TRACKING DEVICES.............................................. 26
VLF PROBE.......................................................... 27
AUDIO TESTING .................................................. 29
MISC. WIRE / AUDIO EVALUATION .......................... 30
PLANNING AND CONDUCTING A SWEEP...................... 31
SWEEP PREPARATION............................................ 31
ESTABLISH A “GAME PLAN”.................................... 31
SWEEP TIPS ......................................................... 32
PHYSICAL SEARCH................................................ 34
i REI CPM-700
TABLE OF CONTENTS
OTHER PROCEDURES AND EQUIPMENT ........................ 37
SPECIFICATIONS........................................................... 41
WARNINGS .................................................................. 45
REI CPM-700 ii
INTRODUCTION
INTRODUCTION
The CPM-700 Countersurveillance Probe/Monitor is a universal sweep tool that can be used to detect and locate a wide variety of surveillance devices. A broad range of probes and accessories are available for the CPM-700 to expand the CPM’s countersurveillance capabilities.
NOTE: Depending on the CPM-700 package purchased, and/or additional probes purchased, you may or may not have all the probes and accessories discussed in this manual.
The CPM-700 detects and locates transmitting devices, quickly and silently, including:
AF (Audio Frequency)……...100 Hz to 15 kHz.
VLF (Very Low Frequency)….15 kHz to 1 MHz and carrier current
RF (Radio Frequency...……..50 kHz to 3 GHz
With the additional probes and accessories, the CPM can detect and locate:
High Frequency transmitters (3 - 12 GHz, such as 802.11 wireless networks and 5.8 GHz cordless telephones, with BMP-1200)
Infrared transmitters (with IRP-700)
Magnetic Leakage (with MLP-700)
Acoustic Leakage vulnerability (with ALP-700)
Special Note
Familiarization with the level of threat, the physical and technical environment, and most importantly the capabilities of the CPM­700 is critical to using the CPM-700 successfully. In an area as sensitive as countersurveillance, it may be necessary for you to employ other supplementary equipment and/or procedures.
The section “Planning and Conducting a Sweep” contains many practical tips for getting the most out of your CPM and other countersurveillance equipment.
1 REI CPM-700
INTRODUCTION
CPM-700 PACKAGES
Several probes and accessories (some of which are optional) are available for the CPM-700. Many of these probes and accessories are available separately, but also in the packages listed below:
CPM-700 STANDARD
The CPM-700 STANDARD package provides the basic tools for users who are only concerned with minimal RF testing; the CPM­700 STANDARD package includes the following:
CPM-700 Countersurveillance Probe/Monitor
Standard RF Probe (50kHz-3GHz)
VLF Carrier Current Probe
TVLF Patch Cable
Auxiliary Patch Cable
Headphones
Soft carrying case
This is the most basic package providing for TSCM RF testing up to 3GHz.
CPM-700 ADVANCED PACKAGE
The CPM-700 ADVANCED package is designed for users who have a need for additional TSCM testing (IR, Acoustic Leakage, Network and Telephone wiring testing, etc.). This package also provides several convenience accessories and includes the following:
CPM-700 Countersurveillance Probe/Monitor
Standard RF Probe (50kHz-3GHz)
Acoustic Leakage Probe
Infrared Probe
VLF Carrier Current Probe
TVLF Patch Cable
Magnetic Leakage Probe
Auxiliary Patch Cable
Modular Phone Adapter for network and phone line
testing
Tape Recorder Patch Cords
REI CPM-700 2
INTRODUCTION
Cigarette Lighter Adapter for powering the CPM from a 12VDC automobile socket
Rechargeable Batteries
Headphones
Soft carrying case
This package includes several accessories for RF analysis up to 3GHz, Infrared analysis, acoustic leakage testing, network and telephone testing adaptors, and other accessories.
CPM-700 DELUXE PACKAGE (12GHz)
The CPM-700 DELUXE package is designed for the serious TSCM user who wants to get the most out of the CPM-700. This package includes all currently available probes and accessories, including the directional Broadband Microwave Probe, which extends the range of the CPM-700 to 12GHz and adds additional sensitivity in the common 2.4 GHz range over the Standard RF Probe. The CPM­700 DELUXE package includes the following:
CPM-700 Countersurveillance Probe/Monitor
Standard RF Probe, frequency range of 50kHz-3GHz
Broadband Microwave Probe (BMP-1200), frequency range
of 2GHz-12GHz (This probe is directional and much more sensitive than the standard RF probe in the common
2.4GHz range.)
Acoustic Leakage Probe for evaluating structural bound audio leakage
RF Sniffer Probe (10MHz-3GHz) for pinpointing surveillance devices where the Standard RF Probe may become saturated with RF energy
Infrared Probe
VLF Carrier Current Probe
TVLF Patch Cable
Magnetic Leakage Probe
Auxiliary Patch Cord
Modular Phone Adapter for network and phone line testing
Tape Recorder Patch Cords
Cigarette Lighter Adapter for powering the CPM from a
12VDC automobile socket
Rechargeable Batteries
3 REI CPM-700
INTRODUCTION
Headphones
Deluxe Hard-shell Case to carry the CPM and all probes
and accessories
The CPM-700 Deluxe package includes all current available probes (including RF up to 12GHz, Infrared, Carrier Current, Acoustic Leakage, etc.), and all available accessories and provides the widest range of test capabilities with the CPM.
Most of the probes and accessories are available separately for replacement; contact REI for replacement probes.
BMP-1200 Broadband Microwave Probe Upgrade
For CPM owners who would like to add the Broadband Microwave Probe (BMP-1200) to their existing CPM (extending the frequency range to 12GHz), REI offers the BMP-1200 Upgrade package, which is backwards compatible with all existing CPMs. The BMP-1200 Upgrade includes the following:
BMP-1200 Probe (2GHz-12GHz)
RF Sniffer Probe (10MHz-3GHz)
Acoustic Leakage Probe
Deluxe Hard-shell Case
The CPM-700 provides a wide range of tools in a single easy-to-use portable kit. Whatever your needs, there is a CPM package that will accommodate you.
REI CPM-700 4
FEATURES OF THE CPM
FEATURES OF THE CPM
POWER SUPPLIES, PROBES, ACCESSORIES
1. Power Sources / Selector Switch:
a. Alkaline Batteries (8 AA cells) - Remove back cover of CPM by
turning two fasteners one-quarter turn counterclockwise. Set the switch to “ALKALINE.”
Selector switch in back of CPM is factory set to “ALKALINE”
Do not charge Alkaline batteries. Damage to the unit will occur.
b. Using Rechargeable Ni-MH or Ni-Cad Batteries
(8 AA cells) – Set the switch to “RECHARGEABLE.” Charge at least eight hours or overnight. Connect the AC adapter to the side of the CPM and plug in to a wall outlet. All rechargeable batteries must be charged before use.
c. AC Adaptor – Connect the adapter supplied by REI to an AC
outlet and to the Adapter input of the CPM-700. If rechargeable batteries are installed, the AC adapter will charge them. The CPM-700 will automatically operate on the battery pack if the AC power fails. NOTE: Do not use any adapter other than the one supplied by REI.
5 REI CPM-700
FEATURES OF THE CPM
2. Standard RF Probe: Checks your environment for hidden phone or room-audio bugs; video transmitters; pulsed tracking transmitters; remote control, frequency-hopping, spread­spectrum, and burst devices up to 3GHz.
a. VLF Probe: Tests for carrier-current
With TVLF adapter attached to the VLF probe, test for carrier current devices on any pair of conductors.
bugs that use AC wiring (or other misc. wiring like telephone, burglar alarm, thermostat wiring, etc.) as a transmission path.
3. The high sensitivity Auxiliary Input Amplifier allows you to listen to suspicious telephone or room wiring for the presence of buried microphones or modifications to equipment.
REI CPM-700 6
4. BMP-1200 Broadband Microwave Probe – Receives RF energy between 2GHz and 12GHz, including frequencies used for wireless networks and many cordless telephones.
5. RF “Sniffer” Probe – Helps to
6. IRP-700 Infrared Probe – Locates infrared transmissions.
7. MLP-700 Magnetic Leakage Probe – Locates carrier current devices, tape recorders and video cameras.
FEATURES OF THE CPM
isolate ‘threat’ transmissions from legitimate broadcast transmissions in RF-rich environments up to 3GHz. Must check within 18” of every object in the target area.
7 REI CPM-700
FEATURES OF THE CPM
8. MPA Modular Phone Adaptor – Rapidly tests each pair of conductors in telephone and network cables or carrier current or audio transmissions
Testing for carrier current devices
Testing for line audio
Modular Phone
Adapter (MPA)
Cable from telephone
TVLF Adaptor
Auxiliary Patch Cable
VLF Probe
To CPM
To CPM
9. TVLF Adaptor – Adapts VLF Probe to check any kind of wiring (not just wall outlets) for carrier current devices (see above).
10. ALP-700 Acoustic Leakage Probe – Detects and evaluates areas vulnerable to acoustic leakage. (Also used with testing of REI’s ANG 2200 – Acoustic Noise Masking System.)
11. NCB – Rechargeable battery pack, 8 Ni-MH cells, size AA
12. CLA – 12 VDC automotive cigarette lighter adapter
REI CPM-700 8
FEATURES OF THE CPM
FRONT PANEL FEATURES
1
2
6
7
8
9
11
3
4
5
10
12
AUDIO GROUP
PHONES (1): Allows the use of silent headphone detection, disconnects the internal speaker.
GAIN (2): Controls the Audio Gain (volume) to the speaker or Headphone Output. Does not affect Record Out level.
FILTER (3): The audio Filter will “band-pass” the audio response for voice levels by enhancing the 500 Hz to 2.5 kHz frequencies. The Filter also removes much of the AC hum on the Auxiliary Input, or video hum when using the RF Probe Input. The Filter processes the audio for both the headphones and the record-out jack. Display shows whether filter is IN or OUT.
MONITOR GROUP
MODE (4): Sets the unit to its Search or Monitor function. The SEARCH mode is used for performing a sweep. The MONITOR mode is used after a sweep to check continually for new devices. Display shows whether Mode is SEARCH or MONITOR
With the CPM in MONITOR mode, a new signal stronger than the THRESHOLD level (see below) will cause the ALERT LED to flash, and the CPM will make an audible TONE.
9 REI CPM-700
FEATURES OF THE CPM
The remaining functions in this group are active only while in the MONITOR mode:
SILENT/TONE (5): Silences the audible beeper during an ALERT. The LED will continue to flash. Display shows whether CPM is in TONE or SILENT mode.
THRESHOLD (6): Moves a pulsing segment to any position on the LCD Bar graph. When the input level exceeds the pulsing segment, the CPM-700 enters an Alert Mode and activates the Remote Output.
The THRESHOLD control is active only in the MONITOR mode.
ALERT (7): LED flashes red while in ALERT mode.
DISPLAY GROUP
INPUT LEVEL (8): Bar graph indicates signal strength of Probe or Auxiliary Inputs; compressed semi-logarithmic with two sensitivity scales.
PULSING SEGMENT (9): In MONITOR mode only, displays the Threshold Point that will activate the Alert mode and Remote Output.
LOW BATT (not shown): Battery voltage indicator; indicates approximately 10% remaining power.
STATUS DISPLAY (10): Shows unit operating conditions made by switch selections and input used.
NOTE: This status display figure is used in this manual to help you verify the current setup. Only one label per block appears at any one time on the actual display, depending on the switch settings.
REI CPM-700 10
FEATURES OF THE CPM
PROBE GROUP
PROBE (11): Input jack for CPM probes. This jack also provides power to “active” CPM probes. The CPM-700 will automatically select this input when a CPM Probe is connected. Connect only CPM probes to this jack. Display shows whether PROBE or AUX jack is in use.
GAIN (12): Selects the internal sensitivity of the Bar graph and audio systems. The HIGH position provides additional Gain to boost low-level input signals. Display shows whether HIGH Gain or LOW gain is selected.
SIDE PANEL FEATURES
A B C D E F
A. AUXILIARY INPUT: Audio input for internal amplifier. Use to test
wires for the presence of audio or control signals.
B. METER: Calibrates the LCD Bar graph to the HIGH GAIN setting.
C. REMOTE: Connects to “remote” compatible input of audio
recorder. Use to start/stop the recording function.
D. RECORD: Provides low level audio output of received sounds,
connects to “microphone” input of recorder.
E. CHARGE: LED indicates charging of nickel-metal-hydride battery.
F. ADAPTER: Accepts power from AC Adapter, and charges nickel-
metal-hydride battery pack (make sure switch is set to “RECHARGEABLE”).
11 REI CPM-700
Loading...