KitchenAid KXW4330Y, KXW4336Y User Manual

30" (76.2 cm) and 36" (91.4 cm) Wall-Mount Canopy Range Hood
PRODUCT MODEL NUMBERS
KXW4330Y KXW4336Y
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10320584C
2/8/12
CABINET OPENING DIMENSIONS
Electrical Requirements:
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.
*For non-vented (recirculating) installations
IMPORTANT:
Minimum distance “X”: 24" (61.0 cm) from electric cooking surface.
Minimum distance “X”: 27" (68.6 cm) from gas cooking surfaces.
Suggested maximum distance “X”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights. See the following chart.
Vented Installations
Min. ceiling height Max. ceiling height
Electric cooking surface 7' 1" (2.16 m) 9' 2" (2.79 m) Gas cooking surface 7' 4" (2.23 m) 9' 2" (2.79 m)
Non-vented (recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking surface 7' 1" (2.16 m) 9' 6" (2.9 m) Gas cooking surface 7' 4" (2.23 m) 9' 6" (2.9 m)
NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10272075 is available from your dealer or an authorized parts distributor. The chimney extension replaces the chimney shipped with the range hood.
PRODUCT DIMENSIONS
10¾" (27.3 cm)
13³⁄₁₆" (33.5 cm)
3³⁄₈" (8.6 cm)
5⁷⁄₈" (15.0 cm)
*28⁵⁄₁₆" (71.9 cm) min. 42⁵⁄₈" (108.3 cm) max.
**24⁵⁄₈" (62.5 cm) min. 38¾" (98.4 cm) max.
24"
(60.8 cm)
17¹¹⁄₁₆"
(45 cm)
5"
(12.7 cm)
19¹¹⁄₁₆" (50.0 cm)
30" (76.2 cm) 36" (91.4 cm)
*For non-vented (recirculating) installation **For vented installations
VENTING REQUIREMENTS
Vent system must terminate to the outdoors, except for non-vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around the cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the vent system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.
Page 1 of 2
10" (25.4 cm) min. 13" (33.0 cm) max.
9¹⁄₂" (24.1 cm)
10" (25.4 cm) min. 13" (33.0 cm) max.
Side cabinet
30" (76.2 cm) or 36" (91.4 cm)
"X"
bottom of
canopy
to cooking
surface
2" (5.1 cm) min. 9" (22.9 cm) min.*
supply cable
entry location
17" (43.2 cm)*
Side cabinet
Centerline
Cooking surface
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10320584C
2/8/12
Page 2 of 2
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, using a Recirculation Kit (which includes charcoal filters and a deflector). To order, see the “Assistance or Service” section.
The following example falls within the maximum recommended vent length of 35 ft (10.7 m).
1 - 90° elbow = 5.0 ft (1.5 m) 1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) Length of system = 13.0 ft (3.9 m)
Venting Methods
This canopy hood is factory set for venting through the roof or wall. A 6" (15.2 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 6" (15.2 cm) round. NOTE: Flexible vent is not recommended. Flexible vent creates back
pressure and air turbulence that greatly reduce performance. Vent system can terminate either through the roof or wall. To vent
through a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
Roof Venting Wall Venting Non-Vented
(Recirculating)
A
Example vent system
90 elbow
6 ft (1.8 m)
Wall cap
B
A. Roof cap B. 6" (15.2 cm) round
vent
B
A. Wall cap B. 6" (15.2 cm) round
vent
B
A
A. Diverter B. 6" (15.2 cm) round
vent
A
2 ft
(0.6 m)