KitchenAid KWCU465S, KWCU405S User Manual

PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
INSTALLATION DIMENSIONS
KWCU405S KWCU465S
Electrical: 120-volt, 60-Hz, AC-only, 15-amp, fused electrical curcuit is required. Use copper wire only.
36" (76.2 cm) Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10140616
09-11-08
®
Maximum length = 35' (10.7 m)
1 — 90° elbow = 5' (1.5 m) 8' (2.4 m) straight = 8' (2.4 m) 1 — wall cap = 0' (0 m)
system length = 13' (3.9 m)
Note: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
Vented installations
Note: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a 40" (101.6 cm) Chimney Extension Kit Part Number 8212710 (Stainless Steel), 8212711 (White), or 8212712 (black) is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.
Important:
Minimum distance “X”: 24” (61.0 cm) Suggested maximum distance “X”: 30” (76.2 cm)
For vented installations, the chimneys can be adjusted for ceilings between 7' 6-3/8" (2.30 m) and 9' 0" (2.74 m).
For non-vented (recirculating) installations, the chimneys can be adjusted for ceilings between 8' 3-3/8" (2.45 m) and 9' 5-1/4" (2.88 m).
30" (76.2 cm) 36" (91.4 cm)
22" (55.9 cm)
Min 27¹⁄₂" (69.8 cm) Max 36¹⁄₂" (92.7 cm)
21¹⁄₄" (54.0 cm)
1¹⁄₄"
(3.2 cm)
3¹⁵⁄₁₆"
(10.0 cm)
10¹⁄₄" (26.0 cm)
11¹³⁄₁₆" (30.0 cm)
18" (45.7 cm) min. clearance upper cabinet to countertop
X*
36" (91.4 cm) countertop height
See Note
30" (76.2 cm) or 36" (91.4 cm) cabinet opening width (if installed between cabinets)
Roof Venting Wall Venting Non-vented
(recirculating)
A. Roof cap B. 6" (15.2 cm)
round vent
A. Wall cap B. 6" (15.2 cm)
round vent
A. Deflector B. 6" (15.2 cm)
round vent
A
A
B
B
B
A
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system
.
Maximum equivalent vent length is 35' (10.7 m).
30" (76.2 cm) 36" (91.4 cm)
22" (55.9 cm)
Min 32" (81.3 cm) Max 38¹⁄₈" (96.8 cm)
22"
(55.9 cm)
1¹⁄₄"
(3.2 cm)
3¹⁵⁄₁₆"
(10.0 cm)
10⁵⁄₈" (27.0 cm)
12" (30.5 cm)
12¹⁄₂" (31.8 cm)
5"
(12.7 cm)
3¹⁄₂" (8.9 cm)
Non-vented (recirculating) installations
6" (15.2 cm) roundVent piece
45° elbow 2.5'
90° elbow 5.0'
(0.8 m)
(1.5 m)
90º elbow
(0.6 m)
Example Vent System
2’
6' (1.8 m)
Wall cap