Kitchenaid KVWB600HBS Dimension Guide

PRODUCT MODEL NUMBERS
Electrical: A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
circuit is required.
30" (72.6 cm) and 36" (91.4 cm) Wall-Mount Canopy Range Hood
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
VENTING METHODS
This canopy range hood is factory set for venting through the roof or through the wall.
A 6" (15.2 cm) round vent system is needed for installation (not included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
Rear Discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, using a Recirculation Kit (which includes charcoal filters and a deflector). To order, see the “Assistance or Service” section.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
PRODUCT DIMENSIONS
Ref. W10674118
12/8/14
Page 1 of 2
The following example falls within the maximum recommended vent length of 35 ft (10.7 m).
1 - 90° elbow = 5.0 ft (1.5 m) 1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) Length of system = 13.0 ft (3.9 m)
KVWB600D KVWB606D
Non-Vented
Roof Venting Wall Venting
A
(Recirculating)
Example Vent System
90 elbow
2 ft
(0.6 m)
6 ft (1.8 m)
10¾" (27.3 cm)
13³⁄₁₆" (33.5 cm)
Wall cap
B
B
B
A
A
A. Roof cap B. 6" (15.2 cm)
round vent
A. Wall cap B. 6" (15.2 cm)
round vent
A. Diverter B. 6" (15.2 cm)
round vent
(60.8 cm)
30" (76.2 cm) 36" (91.4 cm)
5"
(12.7 cm)
19¹¹⁄₁₆" (50.0 cm)
*For non-vented (recirculating) installations
**For vented installations
*28⁵⁄₁₆" (71.9 cm) min. 42⁵⁄₈" (108.3 cm) max.
24"
**24⁵⁄₈" (62.5 cm) min. 38¾" (98.4 cm) max.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10674118
12/8/14
Page 2 of 2
CABINET DIMENSIONS
IMPORTANT:
Minimum distance “X”: 24" (61.0 cm) from electric cooking surface.
Minimum distance “X”: 27" (68.6 cm) from gas cooking surfaces.
Suggested maximum distance “X”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights. See the following chart.
Vented Installations
Min. ceiling height Max. ceiling height
Electric cooking 7' 1" (2.16 m) 9' 2" (2.79 m) surface
Gas cooking 7' 4" (2.23 m) 9' 2" (2.79 m) surface
Non-vented (recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking 7' 1" (2.16 m) 9' 6" (2.9 m) surface
Gas cooking 7' 4" (2.23 m) 9' 6" (2.9 m) surface
*NOTE: The range hood chimneys are adjustable and designed to meet
*varying ceiling or soffit heights depending on the distance X between *the bottom of the range hood and the cooking surface. For higher *ceilings, a Chimney Extension Kit is available from your dealer or an *authorized parts distributor. The chimney extension replaces the chimney *shipped with the range hood. To order, see the Assistance or Service *section.
10" (25.4 cm) min. 13" (33.0 cm) max.
9¹⁄₂" (24.1 cm)
10" (25.4 cm) min. 13" (33.0 cm) max.
Side cabinet
30" (76.2 cm) or 36" (91.4 cm)
"X"
bottom of
canopy
to cooking
surface
Centerline
*For non-vented (recirculating) installations
2" (5.1 cm) min. 9" (22.9 cm) min.*
Vent and power
entry location
17" (43.2 cm)*
Side cabinet
Cooking surface
supply cable
Loading...