KitchenAid KVUB600DSS0 Dimension Guide

A
D
Range Hood - 30" (76.2 cm) and 36" (91.4 cm)
PRODUCT MODEL NUMBERS
LOCATION REQUIREMENTS
KVUB600D KVUB606D
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10674120B
12/12/14
CABINET OPENING DIMENSIONS
Electrical Requirements: A 120 volt, 60 Hz., AC
only, 15-amp, fused electrical circuit is required.
IMPORTANT: Observe all governing codes and ordinances.
It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left wall.
Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.
PRODUCT DIMENSIONS
VENTING REQUIREMENTS
The vent system for venting out of the top of range hood can be terminated either through the roof or wall. Use a 6" (15.2 cm) round vent. The vent system for venting out the rear of the range hood must be terminated through the wall. Use a 3³⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent. For rear venting the Damper Assembly Kit is required. See “Assistance or Service” section to order.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that gently reduces performance.
Page 1 of 2
C
12"
(30.5 cm)
7¼"
(18.4 cm)
2"
(5.1 cm)
(22.9 cm)
9"
(2.6 cm)
13¹²⁄₁₆" (35 cm)
1¹⁄₁₆"
1³⁄₁₆"
(3.0 cm)
⁵⁄₈"
(1.6 cm)
3" (7.6 cm) ­30" (76.2 cm) model 5³⁄₄" (14.6 cm) ­36" (91.4 cm) model
B
D
A
E
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop B. 24" (61.0 cm) min. for electric cooking surfaces
27" (68.6 cm) min. for gas cooking surfaces 30" (76.2 cm) suggested max. - bottom of range hood to
cooking surface C. 30" (76.2 cm) or 36" (91.4 cm) min. cabinet opening width D. 12" (30.5 cm) min. cabinet depth E. 36" (91.4 cm) base cabinet height
29⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model
35⁷⁄₈ (91.1 cm) - 36" (91.4 cm) model
19³⁄₄"
(50.2 cm)
Roof Venting Wall Venting
A
D
A
B
B
C
C
. 6" (15.2 cm) round vent
through roof
B. Round vent: 6" (15.2 cm)
diameter transition piece.
C. 24" (61.0 cm) - 30" (76.2 cm)
D. Roof cap
A. 6" (15.2 cm) round vent
through the wall
B. 3¹⁄₄" x 10" (8.3 x 25.4 cm)
through the wall (purchased separately)
C. 24" (61.0 cm) - 30" (76.2 cm)
above electric cooking surface 27" (68.6 cm) - 30" (76.2 cm) above gas cooking surface
D. Wall cap
NOTE: 12" (30.5 cm) high cabinets without a soffit may allow the 6" (15.2 cm) vent and vent cover to be seen.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10674120B
12/12/14
Page 2 of 2
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) or Larger Round Vent System Vent Piece Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
6" (15.2 cm) or larger 0.0 ft wall cap (0.0 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft to 6" (15.2 cm) or larger (1.4 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft to 6" (15.2 cm) or larger (1.5 m) 90° elbow
Example vent system
Maximum Recommended Length = 50 ft (15.2 m)
1 - 90° elbow = 5.0 ft (1.5 m) 1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) Length of 7" (17.8 cm) system = 13.0 ft (3.9 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System Vent Piece Round
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft 90° elbow (1.5 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 12.0 ft flat elbow (3.7 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 0.0 ft wall cap (0.0 m)
Example vent system
Maximum Recommended Length = 35 ft (10.7 m)
1 - 90° elbow = 5.0 ft (1.5 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) 1 - wall cap = 0.0 ft (0.0 m) Length of 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) = 13.0 ft (3.9 m)
system
Non-Vented (recirculating) Installations Through the Soffit/ Cabinet
If it is not possible to vent cooking fumes and vapors to the outside, the range hood can be used in the non-vented (recirculating) version, using a recirculation kit. The recirculation kit Part Number is W10490330. See Assistance or Service section to order.
For non-vented (recirculating) installations only, the range hood can be vented indoors through the top of the cabinet or soffit.
Wall cap
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
6 ft (1.8 m)
90˚ elbow
6 ft (1.8 m)
2 ft (0.6 m)
Wall cap
Through Cabinet Through Soffit
A
A
B
G
G
B
F
C
D
D
F
A. Ceiling B. Vent cover C. Soffit D. 6
" (15.2 cm) vent
E. Range hood
H
E
F. Cabinet G. Wall H. 17" (43.2 cm) min. vent cover
height
E
Loading...