For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230
or visit our website at www.kitchenaid.com
In Canada, for assistance, installation and service, call: 1-800-807-6777
or visit our website at www.kitchenaid.ca
HOTTE DE CUISINIÈRE EN ÎLOT DE
36" ET 42" (91,4 CM ET 106,7 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service composez le 1-800-807-6777
Table of Contents/Table des matières.............................................................................2
ou visitez notre site Web à www.kitchenaid.ca
LI32LC/W11165103A
TABLE OF CONTENTS
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
TABLE DES MATIÈRES
RANGE HOOD SAFETY .................................................................2
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
2
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
3
INSTALLATION REQUIREMENTS
†®TORX is a registered trademark of Acument Intellectual Properties, LLC.
27" (68.6 cm)
36" (91.2 cm)
42" (106.4 cm)
Tools and Parts
Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
Tools Needed
■ Level
■ Drill with 1¼" (3.0 cm), ³⁄₈" (9.5 mm), ⁷⁄₆₄" (2.75 mm) and
¹⁄₈" (3.0 mm) drill bits
■ Pilot hole drill bits (determined by chimney support
attachment method)
■ Pencil
■ Wire stripper or utility knife
■ Tape measure or ruler
■ Pliers
■ Caulking gun and weatherproof caulking compound
■ Vent clamps
■ Jigsaw or keyhole saw
■ Flat-blade screwdriver
■ Metal snips
■ Phillips screwdriver
Parts Needed
■ Home power supply cable
■ ½" (12.7 mm) UL listed or CSA approved strain reliefs (2)
■ UL listed wire connectors (3)
For Vented Installations, You Will Also Need:
■ W all or roof cap (1)
■ Metal vent system
For Non-Vented (Recirculating) Installations, You Will Also
Need:
■ Recirculating Kit Part Number W10692909 for non-vented
(recirculating) installations only. See “Assistance or Service”
section to order.
■ 6" (15.2 cm) round metal vent duct. Length required is
determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
■ Hood canopy assembly with ventilator, LED and Halogen
lights installed.
■ Filter—installed in hood canopy
■ 4.2 x 8 mm screws (60)
■ 5 x 45 mm screws (4)
■ Mounting template
■ Upper vent covers (2)
■ Lower vent covers (2)
■ Vent transition with backdraft damper installed
■ 3.5 x 9.5 mm mounting screws (2)
■ Plastic vent clips (4)
■ Upper horizontal support bracket
■ Horizontal support
■ Vertical supports (8)
■ 3.5 x 6.5 mm screws (4)
■ 2.9 x 3 mm screws (2)
■ T-10 Torx
■ T20 Torx adapter
®†
adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
■ For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 100 lbs (45.4 kg).
This range hood is recommended for use with cooktops with a
maximum total rating of 65,000 BTUs or less.
The range hood is factory-set for venting through the roof.
For non-vented (recirculating) installation see “Non-Vented
(Recirculating) Installation” in “Install Range Hood” section.
Recirculation Kit Part Number W10692909 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
*Vented installations only
**Non-vented (recirculating) installations only
4
Installation Dimensions
B
CA
D
A. Ceiling height
B. Hood height from ceiling to bottom of the
range hood: A - C - D = B
C. 24" (61.0 cm) minimum to 36" (91.4 cm)
maximum suggested hood height
D. Countertop height
IMPORTANT:
Minimum distance “C”: 24" (61.0 cm) from electric cooking
surface.
Minimum distance “C”: 27" (68.6 cm) from gas cooking
surface.
Suggested maximum distance “C”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights. See
the following chart.
Vented Installations
Min. ceiling heightMax. ceiling height
Electric cooking
surface
Gas cooking
surface
Non-Vented (Recirculating) Installations
Electric cooking
surface
Gas cooking
surface
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights, depending on the
distance “C” between the bottom of the range hood and the
cooking surface. For higher ceilings, a Chimney Extension Kit is
available from your dealer or an authorized parts distributor. The
chimney extension replaces the upper chimney shipped with the
range hood. To order, see the “Assistance or Service” section.
7' 9" (2.36 m)9' 10" (3.0 m)
8' (2.44 m)9' 10" (3.0 m)
Min. ceiling heightMax. ceiling height
7' 9" (2.36 m)10' 4" (3.15 m)
8' (2.44 m)10' 4" (3.15 m)
Venting Requirements
■ Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
■ Do not terminate the vent system in an attic or other enclosed
area.
■ Do not use 4" (10.2 cm) laundry-type wall caps.
■ Use metal vent only. Rigid metal vent is recommended. Do
not use plastic or metal foil vent.
■ The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
For the Most Efficient and Quiet Operation:
■ Use a straight run or as few elbows as possible.
■ Use no more than three 90° elbows.
■ Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows, if more than 1 elbow is used.
■ Do not install 2 elbows together.
■ Use vent clamps to seal all joints in the vent system.
■ Use caulking to seal exterior wall or roof opening around the
cap.
■ The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold airflow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
This island hood is factory-set for venting through the roof.
A 6" (15.2 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall. To vent
through a wall, a 90° elbow is needed.
For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, using a Recirculation Kit (which includes charcoal filters
and a deflector). To order, see the “Assistance or Service”
section.
5
Roof VentingNon-Vented (Recirculating)
A
B
A
B
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
A. Roof cap
B. 6" (15.2 cm) round vent
A. Deflector
B. 6" (15.2 cm) round vent
NOTE: Wall venting can be an option for 2-story homes.
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece6" (15.2 cm) Round
45° elbow2.5 ft
(0.8 m)
90° elbow5.0 ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
■ A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.
■ If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
■ Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial/rating plate.
The model/serial/rating plate is located behind the filter on
the rear wall of the range hood.
■ Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
Example Vent System
The following example falls within the maximum vent length of
35 ft (10.7 m).
1 - 90° elbow= 5.0 ft (1.5 m)
1 - wall cap= 0.0 ft (0.0 m)
8 ft (2.4 m) straight= 8.0 ft (2.4 m)
System length= 13 ft (3.9 m)
6
INSTALLATION INSTRUCTIONS
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Prepare Location
■ It is recommended that the vent system be installed before
the range hood is installed.
■ Before making cutouts, make sure there is proper clearance
within the ceiling for exhaust vent.
■ Range hood is to be installed 24" (61.0 cm) min. for electric
cooking surfaces, or 27" (68.6 cm) min. for gas cooking
surfaces, to suggested maximum of 36" (91.2 cm) above the
cooking surface.
■ Check your ceiling height and the range hood height
maximum before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, or non-vented.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
Complete Preparation
1. Determine the required location for the home power supply
cable, and then drill a ½" (1.3 cm) diameter hole for wire
access.
2. Run wire through the home power supply cable according to
the National Electrical Code or CSA Standards and local
codes and ordinances. There must be enough ½" conduit
and wires from the fused disconnect (or circuit breaker) box
to make the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
3. For vented installations only: Using a jigsaw or keyhole
saw, cut a 6½" (16.5 cm) diameter hole for the vent duct.
4. Attach the upper horizontal support bracket to the ceiling
with 4 - 5 x 45 mm #2 Phillips wood screws.
NOTE: Upper horizontal support screws must be into a
ceiling support structure capable of holding 80 lbs (36.6 kg).
4. Using 2 or more people, lift range hood onto covered surface.
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the ceiling where the
range hood will be installed, after considering the
requirements for ceiling support structures. See the “Location
Requirements” section. Make sure the range hood is
centered over the cooking surface.
2. Tape template in place on the ceiling at the marked
centerline. The line for the front of the range hood should be
parallel to the front of the cooktop.
3. Use a pencil to mark the mounting screws, wire access and
duct hole locations on the ceiling.
NOTE: Mounting hole locations should be into a ceiling
support structure capable of holding 100 lbs (45.4 kg).
Remove the template.
4. Drill 4 - ³⁄₁₆" (4.8 mm) pilot holes for mounting the upper
horizontal support.
A
B
A. Upper horizontal support
B. 5 x 45 mm screws (#2 Phillips drive)
Install In-Line Smart Kit - Optional
NOTE: Your range hood can work with either an internal or an in-
line (external) blower motor system. An optional In-Line Smart Kit
(purchased separately) allows the blower motor that comes with
this range hood to be installed in a location other than inside the
range hood cavity.
CAUTION: To reduce the risk of fire and electric shock, install this
range hood only with the In-Line Smart Kit manufactured by
Whirlpool, Part Number W10692945.
For installation see the In-Line Smart Kit installation instructions.
See the “Assistance or Service” section to order.
7
Assemble and Install Range Hood
1. Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
2. Install the lower horizontal support with 8 - 4.2x8 mm
screws.
3. Install the 4 upper vertical supports with 16 - 4.2x8 mm
screws.
A
B
A. 4- Upper vertical supports
B. 16 - 4.2x8 mm screws
A
B
A. Lower horizontal support
B. 8 - 4.2x8 mm screws
4. Install the structure to the upper horizontal support with
16 - 4.2x8 mm screws.
A
B
B.
A. Upper horizontal support
B. 16 - 4.2x8 mm screws
8
5. Using 2 or more people, lift the range hood assembly under
the structure.
A
B
7. Install the 4 lower vertical supports with 16 - 4.2x8 mm
screws. Make sure all screws are tightly fastened.
A
B
A. 4 - Lower vertical supports
B. 16 - 4.2x8 mm screws
A. Lower vertical supports
B. Range hood assembly
6. Attach the range hood assembly to the lower vertical
supports with 2 leveling screws and 2 nuts.
A
A. 2 - Leveling screws
B. Lower vertical support
C.
Place leveling screws
through the structure
D. Nut
D
B
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections with
vent clamps.
3. Use caulk to seal all openings.
Non-Vented (Recirculating) Installation
1. Attach the air deflector to the upper horizontal support using
4 mounting screws.
B
A
B
A. Deflector
B. Mounting screws
2. Measure the length of 6" (15.2 cm) duct needed to connect
C
the transition to the deflector.
NOTE: Vent should fit up inside the deflector 1" (2.5 cm)
minimum.
3. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket, and then
replace after vent section is in place.
4. Seal all connections with vent clamps.
9
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
C
B
A
B
C
D
E
F
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
A
B
C
C
6. Use UL listed wire connectors and connect white wires (E)
together.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box, and then install a
UL listed or CSA approved ¹⁄₂" (12.7 mm) strain relief.
A. Knockout
B. Terminal box
C. Terminal box cover
4. Run home power supply cable through strain relief and into
the terminal box.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the “Assistance or Service”
section for information on ordering.
NOTE: Use only with range hood cord connection kits that have
been investigated and found acceptable for use with this model
range hood.
Install Duct Covers
NOTE: Remove the film from the duct covers.
1. Assemble the upper duct covers together, and then install the
duct covers around the support frame. The larger hole in the
flanges of the upper duct cover must be outside the smaller
hole in the mating flange of the other upper duct cover.
2. Secure the upper duct covers together with two 3.5 x 6.5 mm
screws at the top and two 2.9 x 3 mm screws at the bottom.
Install 1 screw on each side at the top and bottom of the
assembled duct covers.
A. Home power supply cable
B. UL listed or CS
train relief
s
C. Black wires
5. Use UL listed wire connectors and connect black wires (C)
together.
10
A approved
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
A. 3.5 x 6.5 mm screws (2)
B. Assembly holes (larger hole outside of
smaller hole on both sides)
C. 2.9 x 3 mm screws (2)
NOTE: For non-vented (recirculating) installation, the slotted
A
B
C
B
C
A
D
B
A
A
B
D
C
A
B
D
C
A
B
holes in the upper duct covers will be visible when assembled.
For vented installations, the slotted holes will be hidden down
inside the lower duct covers.
5. Install the lower duct cover (front) to the range hood canopy.
Spread the lower duct cover opening slightly and position it
over the upper duct cover. Set the lower duct cover in place.
Position so the flanges of the lower duct cover set into the
flanges of the upper duct covers.
A. Top toward ceiling
B. Slots installed up for non-vented installations
C. Slots installed down for vented installations
3.
Slide the upper duct covers up the frame to the ceiling, and then
secure to the upper horizontal support with 2 - 3.5 x 6.5 mm
screws.
A. 3.5 x 6.5 mm screw
B. Slotted holes (2)
C. Upper duct covers
D. Ceiling
4. Place the long end of the plastic clips (2) into the bottom of
the front lower duct cover.
A. Range hood canopy
B. Plastic clips
C. Lower duct covers
D. Upper duct covers
6. Install the lower duct cover (rear) to the range hood canopy.
Spread the lower duct cover opening slightly and position it
over the upper duct cover. Set the lower duct cover in place.
Position so the flanges of the lower duct cover set into the
flanges of the upper duct cover. Make sure the front and rear
lower duct covers mate properly.
NOTE:
When assembling the rear lower duct cover to the front
lower duct cover, the flange (both sides) must be placed over the
plastic clip to secure the lower duct covers together at the bottom.
A. Lower duct cover (rear)
B. Plastic clips
C. Lower duct covers
D. Upper duct covers
7. Secure the lower duct covers together at the top using
plastic clips (2). Use one plastic clip on each side.
A. Lower duct cover - (front)
B. Plastic clips (2) (long end for front placement)
A. Plastic clips (2)
B. Lower duct covers top clip area
11
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.