Ice Maker
PRODUCT MODEL NUMBERS
CABINET OPENING DIMENSIONS
KUIA18NNJ
KUIA18PNL
KUIS18NNJ
KUIS18PNJ
KUIV18NNM
Electrical: 115-volt, 60-Hz, AC-only, 15-ampere
grounded circuit is required. A time-delay fuse or
circuit breaker and separate circuit is
recommended.
Water: A cold water supply using 1/4 in. O.D. soft
copper tubing with shutoff valve.
Drain: Either a gravity-drain system or
condensate pump to carry water to an existing
drain.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 2217408
03-30-04
®
A. Recommended location for
electrical and plumbing fixtures.
B. Floor level
Drain lines must have a minimum of 5⁄8 in.
(15.88 mm) inside diameter.
Drain lines must have a 1 in. drop per 48 in. (2.54 cm
drop per 122 cm) of run or 1⁄4 in. drop per 12 in.
(6.35 mm per 30.48 cm) and must not have low
points where water can settle.
The ideal installation has a 1-1⁄2 in. (3.81 cm)
standpipe installed directly below the outlet of the
drain tube as shown.
You must maintain a 1 in. (2.54 cm) air gap between
the drain pump hose and the standpipe.
A.Water Pan
Drain
B. Water Valve
A. Drain Hose
B. 1 in. (2.54 cm) Air Gap
C. Standpipe
D. Center of drain should be 20 in.
(50.80 cm) from front of door.
DRAIN REQUIREMENTS
1/2
14
"
(36.8 cm)
34"
(86.4 cm)
Min.
1/2
34
"
(87.6 cm)
Max.
1/2
3
(8.9 cm)
9"
"
(22.9 cm)
1/2
28
"
(72.4 cm)
A
B
5¹¹⁄₁₆"
(14.5 cm)
24"
(60.1 cm)
(45.7 cm)
15¹⁄₄"
(38.7 cm)
18"
8¹³⁄₁₆"
(22.4 cm)
2⁷⁄₈"
(7.27 c
(1.9 cm)
20" (50.80 cm)
1⁷⁄₈"
1" (2.5 cm)
(3.8 cm)
1¹⁄₂"
A
B
C
D