Drawer Dishwasher |
||||||||
|
|
|
|
||||||
PRODUCT MODEL NUMBERS |
|
|
|
|
LOCATION REQUIREMENTS |
||||
|
|
|
|
|
|
|
|
|
|
|
KUDD03DT |
|
|
|
IMPORTANT: Observe all governing codes and ordinances. Failure to meet codes and |
||||
|
KUDH03DT |
|
|
|
ordinances could lead to fire or electrical shock. |
||||
ELECTRICAL REQUIREMENTS |
|
|
|
Proper installation is your responsibility. |
|||||
|
|
|
● Contact a qualified installer to ensure that the dishwasher is installed to meet all electrical and |
||||||
|
|
|
|
|
|
|
|
plumbing national and local codes and ordinances. |
|
Contact a qualified electrician. |
|
|
|
||||||
|
|
|
● Install the dishwasher as specified in these instructions. |
||||||
Ensure that the electrical installation is adequate |
|||||||||
● Have everything you need to properly install dishwasher. |
|||||||||
and in conformance with all national and local |
● Keep the dishwasher and water lines leading to dishwasher from freezing. Damage from freezing |
||||||||
codes and ordinances. |
|
|
|
|
is not covered by the warranty. |
||||
You must have: |
|
|
|
● This dishwasher is manufactured for indoor use only. |
|||||
● 120-volt, 60 Hz, AC-only, 15or 20amp fused |
● Install and level dishwasher on a floor that will hold the weight, and in an area suitable for its |
||||||||
|
electrical supply. |
|
|
|
|
size and use. |
|||
● Copper wire only. |
|
|
|
|
PRODUCT DIMENSIONS |
||||
We recommend: |
|
|
|
|
|||||
|
|
|
|
|
●A time-delay fuse or circuit breaker.
●A separate circuit.
DRAIN REQUIREMENTS |
24" |
|
23³⁄ " |
|
(61 cm) |
|
(59.5 cm) |
||
|
|
|
|
|
|
|
|
|
|
●Use the new drain hose supplied with your dishwasher. If this is not long enough, use a new drain hose with maximum length of 12 ft (3.7 m) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the 1" (2.5 cm) drain connector of the
dishwasher. |
|
33³⁄" |
|
● Connect drain hose to waste tee or disposer inlet |
(85.7 cm) |
above drain trap in house plumbing and 20" |
|
(50.8 cm) minimum above the floor. It is |
|
recommended that the drain hose either be looped |
|
up and securely fastened to the underside of the |
|
counter, or be connected to an air gap. |
|
19¹⁄ " |
1¹⁄ " |
(48.9 cm) |
(3.75 cm) |
● Use a drain air gap if the drain hose is connected |
INSTALLATION CLEARANCES |
|
|
||
to house plumbing lower than 20" (50.8 cm) |
|
|
|||
above the subfloor or floor. |
|
|
|
|
|
Cutout dimensions |
|
Preferred utility area |
|
||
● Use ¹⁄ " (1.3 cm) minimum I.D. drain line fittings. |
|
|
WATER SUPPLY REQUIREMENTS |
|
|
|
● A hot water line with 20-120 psi (138-862 kPa) |
24" |
|
A |
(61 cm) |
|
||
water pressure. |
|
|
|
● 120°F (49°C) water temperature at dishwasher. |
|
|
¹⁄ " |
● Flexible braided fill line (¹⁄ " minimum plastic |
|
|
(1.3 cm) |
24" |
33⁄" |
|
|
tubing is not recommended). |
(61 cm) |
(85,7 cm) |
25" |
|
|
|
(63.5 cm) |
|
|
|
B |
|
|
|
8" |
|
|
|
(20.3 cm) |
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation |
Ref. W10300220 Rev A |
Instructions packed with product. Specifications subject to change without notice. |
2-16-10 |