Whirlpool - CIC 8/Ib/Oq Z:zo PM _A55 I/ZI _zgnnrax
IMPORTAN
Read and save
these instructions.
IMPORTANT:
Installer: 8afore installingthe hood liner,read
the InstallationInstrumionsforthe exterior
blowerusedwith hoodliner,
Leave Installation Instructions with the
homeowner,
Homeowner: KeepInstallation Instructions
for future reference.
Save Installation Instructions for local
electrical inspector's use.
Part No. 436001862/8285495
Quick Reference
Table of Contents:
Pages
[] Beforeyou start
[] Electricalrequirements
[] Cabinetdimensions
[] Product dimensions
I_ - 151 Installationsteps
[]- [] UseandCareInformation
[] Wiringdiagram
[] Warranty
[_ -I10_ RequestingAssistsnceor
Service
Whirlpool - ClC 8/16/04 2:25 PM PAGE 1/21 RightFax
WARNING --TO REDUCE THE
RISK OF FIRE, ELECTRIC
SHOCK. OR INJURY TO
Your safety and the safety of
nthem is very important.
We haveprovidedmanyimportant
safetymessagesinthismanualand
onyourappliance.Alwaysreadand
obeyallsafetymessaoes.
Thisisthesafetyalertsymbol
Thissymbolalertsyouto
potentialhazardsthatcankill
or hurtyouandothers.Allsafety
messaoeswillfollow thesafetyalert
symbolandeithertheword"DANGER"
or'WARNING".Thesewordsmean:
Youcanbe killedor seriouslyInjured
ityoudon't_ lollow
Instm_ione.
Youcanbe killedor seriouslyinjured
ifyoudon'tfollowinstructions.
Allsafetymessageswilltell youwhat
thepotentialhazardis,LelJyouhowto
reducethechanceof injury,andtell
youwhatcanhappenifthe
instructionsarenotfollowed.
IMPORTANT: Observe all
governing codes and ordinances.
Proper installation is your
responsibility. Make sure you have
everything necessaryfor correct
installation. It is the responsibility of
the installer to comply with the
clearances specified.
Checkthe location where the hood
liner will be installed.The location
should be away from strong draft
areas, such as windows, doors, and
strong heating vents.
Mobilehomeinstallation
The installation of this hood liner
must conform to the Manufactured
Home Construction Safety
Standards,Title 24 CFR, Part 328
(formerly the Federal Standard for
Mobile Home Construction and
Safety,Title 24, HUD, Part 280) or
when such standard is not
applicable, the Standard for
Manufactured Home Installation
1982 (Manufactured Home Sites,
Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition,
or with local codes.
PERSONS, OBSERVE THE
FOLLOWING:
Installationwork and electrical
wiring must be done by qualified
]ersan(s) in accordance with all
applicable Codesand Standards,
including Fire Rated
Construction. Sufficient air is
needed for proper combustion
and exhausting of gasesthrough
the flue (chimney) offuel burning
equipment to prevent back
drafting. Follow the heating
equipment manufacturer's
guideline and safety standards
such as those published by the
National Fire Protection
Association (NFPA),and the
American Society of Heating
Refrigeration and Air
Conditioning Engineers
(ASHRAE),and the localcode
authorities.
When cuttingor drillingintowall or
ceiling,do not damage electrical
wiringand other hiddenutilities.
Ducted fans mustalways be
ventedto the outdoors.
WARNING -- To reducethe risk
offire, use onlymetal ductwork.
This unitmust be grounded.
Thishoodliner mustbe usedwith
ExteriorBlowerModels:
KPEC992M rated for 900 cfm
(25.5 cm/m) or.
KPEU722M rated for 1200 cfm
(34.0 cm/m).
Both models are available from
your dealer.
This fan suitabable for usewith
solid-state speed controls.
Tools and
materials needed
for installation:
• compassor11"(27.9cm) circletemplate
• fiat bladescrewdriver
• Phillipsscrewdriver
• plTers
• metalsnips
• drill
• 1-1/4"13.0cm)die. drill bit
• 5/16' (7.9cm)dis.drill bit
• pencil
• ruler
• sabersawor keyholesaw
• ducttape
• 3/4"(10.0rnm}U.L- or C.SA.-Listed
strainrelief
IMPORTANT:Observe all
governing codes and ordinances.
The Exterior Blower is connected
to the fused electrical system at
the wiring box of the Hood Liner.
refer to the Installation
Instructions supplied with the
Exterior Blower model for the
electrical system.
It is the customer's responsibility:
•To contact a qualified electrical
installer.
•To assure that the electrical
installation is adequate and in
conformance with National
Electrical Code, ANSI/NFPA 70
-- latest edition*, or CSA
Standards C22.1-94, Canadian
Electrical Code, Part 1 and
C22.2 No.0-M91 - latest
edition** and all local codes
and ordinances.
A 120-volt, 60 hz,AC-only, fused
electrical system ia required. A
separate 15-amp circuit is
recommended.
A separate ground wire must be
used. It is recommended that a
qualified electrician determine
that the ground path isadequate..
Do not ground to a gas pipe.
Check with a qualified electrician if
you are not sure range hood is
properly grounded.
Do not have a fuse in the neutral
or ground circuit.
The connection at the hood liner
wiring box must be with copper
wire only.
IMPORTANT:
Save installation Instructions for
electrical inspector's use.
The 120-volt supply to the hood
liner wiring box should be
connected directly to the fused
disconnect (or circuit breaker) box
through flexible armored or
nonmetallic sheathed copper cable,
A U,L.- or C.S.A,-listad strain relief
must be provided at each end of the
power supply cable, Wire sizes
(COPPERWIRE ONLY) and
connections must conform with the
rating of the appliance as specified
on the model/serial rating plate.
Wire sizes must conform to the
requirements of the National
Whirlpool - ClC 8/18/04 2:25 PM PAGE 1/21 RightFax
ElectricalCodeANSI/NFPA70 --
latestedition*, or CSAStandards
C22.1-94,Canadian ElectricalCoda
Part 1 and C22.2 No. 0-M91 - latest
edition** and all local codas and
ordinances.
i
hoodl]nerls
22"(55.9cm)
deep
A UI.- orC.S.A.-listsd strainrelief
mustbe providedatthe power
supplycableelectricalknockoutof
the HoodLiner,
rain. cabinet openlng wldths:
36" (914 cm) model, 36" (91.4 cm)
48" (121,9 cm) model, 48" (121.9 cm)
30"(76,2 cm) mln,
he] ht above
caogklng surface
Copies o¢the Ka ndalds lilr_d may be
obmined from:
* NaUonal am PmtectionAr_odation
One Bst_erymamh Park
QUnq/, Massachusetts 02268
w* CSA Intern_onst
8501 East PleasantYalley Road
Cleveland, Ohio _,4131-5675
determine hood suppoe depth so
that front enclosure Isflush with
adJolning enclosure.
.,,,,,,,,x_.,,,,,,,,,,_ front
_ JW_;f_jili_E!_iiiiiii__iiii_iiii_ enclosure
........_====="==_ _ [II
hood liner
hood support
must be capable
of supportln
50 Ibs. (22,7gkg)
/ _JN
electrical
knockouts
36" (91.4 cm) model:
35-13/16" (91`0 cm)
48" (121`9 cm) model:
47-13/16" (121.4 cm)
5-1B/16=
(15.1 cm)
2-3/4" 17-5/16"
(7.0cm) (40.0 cm) center line
(5.1 cm)
of hood
- ._, .
5-15/16"
(19,1cm)
36" (91,4 cm,) model:"'--...
15-23/32 (39.9 cm) "'_,_.
_,8"(121,9 cm) model: /
21-23/32" (552
36=(91,4 cm) model:
31-7/1a" (79,9 cm)
48" (121,9 cm) model:
43-7/16" (110.3cm)