KitchenAid KPEC992M Dimension Guide

17-3/4"
(45.1 cm)
23-1/4"
(59.1 cm)
7-1/4"
(18.4 cm)
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
VENTING REQUIREMENTS
KPEC992M
Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical supply. Use copper wire only. A time­delay fuse or circuit breaker and separate circuit is recommended.
900 cfm Exterior Blower
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8285494
10-20-04
®
Maximum length of vent system
Determine the length of vent system you need
90° elbow = 5 ft. (1.5 m)
1 ft. round = 1 ft. (0.3 m)
45° elbow =
2.5 ft. (0.8 m)
Recommended standard 10" (25.4 cm) fittings
Vent Length
10" (25.4 cm) round 55 ft. (16.8 m)
It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, if should be transitioned to 10" (25.4 cm) round vent as soon as possible.
For best performance, use no more than three 90° elbows. If more than one elbow is used, make sure that there is a minimum of 24 inches (61 cm) of straight vent between any two elbows. Do not install two elbows together.
To calculate the length of system you need, add the equivalent feet (meters) from chart below for each vent piece that will be needed.
install this side of the fan facing an unoccupied space.