KitchenAid KHWV01R User Manual

PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
KHWV01R
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 3957648
06-27-06
RECESSED AREA AND CLOSET INSTALLATION WITH OR WITHOUT PEDESTAL
DRAIN SYSTEMS OPTIONS
A.Front view B. Side view C. Cabinet with vents
7" (17,8 cm)
*
7" (17,8 cm)*
4"
(10,2 cm)
33"
(83,8 cm)
27"
(68,6 cm)1"(2,5 cm)
1"
(2,5 cm)1"(2,5 cm)
C
B
A
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
Electrical: To supply the required 3 or 4 wire, single phase, 120/240 volt 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Exhaust venting: Exhaust your dryer to the outside. Four inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
Recommended installation spacing for cabinet installation
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
*Includes door handle
**Includes feet extended 1" (2.5 cm)
Pro Line®Front-Loading Washer
®
Standpipe drain system – wall or floor (view A & B)
The standpipe drain requires aminimum diameter standpipe of 2" (5 cm). The minimum carry-away can be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 30" (76.2 cm) high and no higher than 96" (244 cm) from the bottom of the washer.
Laundry tub drain system (view A)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 30" (76.2 cm) above the floor.
Floor tub drain system (view B)
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses might be needed.
57"
(144.8 cm)
27"
(68.6 cm)
42"
(106.7 cm)**
30" min.
(76.2 cm)
A
B
3"
(7.6 cm)
3"
(7.6 cm)
C
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
A
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
(2.5 cm
1"
)
33"
(83.8 cm)
B
48 in.
(310 cm 2)*
24 in.
(155 cm 2)*
4" (10.2 cm)
2
2
*Required spacing
28" min.
30" min.
(76.2 cm)
(71 cm)
DC