Electrical: A 120-volt, 60-Hz, AC-only,
15-amp, fused electrical circuit is required.
A time-delay fuse or circuit breaker is also
recommended. It is recommended that a
separate circuit serving only this hood be
provided.
36" and 48" Hood Liner with internal Blower
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 9760426
07-19-05
®
hood support must be capable of
supporting 40 lbs. (18.1 kg) for
36" (91.4 cm) model or 55 lbs. (25 kg)
for 48" (121.9 cm) model
hood liner is
22" (55.9 cm)
deep
min. cabinet opening widths:
36" (91.4 cm) model, 36" (91.4 cm)
48" (121.9 cm) model, 48" (121.9 cm)
recommended 24" to 36"
(61.0 cm to 91.4 cm)
above cooktop
20
³⁄₈
"
(51.8 cm)
14
¹⁄₈
"
(35.9 cm)
43
⁷⁄₁₆
"
(110.3 cm)
17
⁵⁄₁₆
"
(44.0 cm)
22"
(55.9 cm)
2
³⁄₄
"
(7.0 cm)
2"
(5.1 cm)
¹⁵⁄₁₆
" (2.4 cm)
dia.
⁷⁄₃₂
" (5.6 mm)
dia.
35
⁵⁄₈
"
(90.5 cm)
2
³⁄₁₆
"
(5.6 cm)
47
¹³⁄₁₆
"
(121.4 cm)
20
¹⁄₄
"
(51.4 cm)
centerline
³⁄₄
"
(19.1 mm)
7
⁷⁄₈
"
(20.0 cm)
5
¹⁵⁄₁₆
"
(15.1 cm)
48" (121.9 cm) model
9
³⁄₈
"
(23.8 cm)
15
⁵⁄₈
"
(39.7 cm)
31
⁷⁄₁₆
"
(79.9 cm)
17
⁵⁄₁₆
"
(44.0 cm)
22"
(55.9 cm)
2
³⁄₄
"
(7.0 cm)
2"
(5.1 cm)
¹⁵⁄₁₆
" (2.4 cm)
dia.
⁷⁄₃₂
" (5.6 mm)
dia.
27
¹⁄₂
"
(69.9 cm)
2
³⁄₁₆
"
(5.6 cm)
35
¹³⁄₁₆
"
(91.0 cm)
14
³⁄₁₆
"
(36.0 cm)
centerline
³⁄₄
"
(19.1 mm)
7
⁷⁄₈
"
(20.0 cm)
5
¹⁵⁄₁₆
"
(15.1 cm)
36" (91.4 cm) model
9
³⁄₈
"
(23.8 cm)
9
³⁄₈
"
(23.8 cm)
90° elbow
wall cap
1 — 90° elbow = 5 ft. (1.5 m)
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
1 — wall cap = 0 ft. (0 m)
system length = 13 ft. (3.9 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
Example vent
system
Vent piece 6" (15.2 cm) round or
10" (25.4 cm) round
45° elbow 2.5 feet
(0.8 m)
90° elbow 5.0 feet
(1.5 m)
To calculate the length of the
system you need, add the
equivalent feet (meters) for each
vent piece used in the system.
Maximum equivalent vent length
is 35 feet (10.7 meters) for 6"
(15.2 cm) vent, 60 feet (18.3 m)
for 10" (25.4 cm) vent.
The 36" (91.4 cm) model requires a 6" (15.2 cm) round vent system for installation
(not included). The 48" (121.9 cm) model requires two 6" (15.2 cm) round vent
systems or a 10" (25.4 cm) round vent system for installation. The hood exhaust
opening is 6" (15.2 cm) round.