KitchenAid KHVU761R, KHVU781R Dimension Manual

PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
CABINET DIMENSIONS
VENTING REQUIREMENTS
KHVU761R KHVU781R
Electrical: A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this hood be provided.
36" and 48" Hood Liner with internal Blower
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 9760426
07-19-05
®
hood support must be capable of supporting 40 lbs. (18.1 kg) for 36" (91.4 cm) model or 55 lbs. (25 kg) for 48" (121.9 cm) model
hood liner is 22" (55.9 cm) deep
min. cabinet opening widths: 36" (91.4 cm) model, 36" (91.4 cm) 48" (121.9 cm) model, 48" (121.9 cm)
recommended 24" to 36" (61.0 cm to 91.4 cm) above cooktop
20
³⁄₈
"
(51.8 cm)
14
¹⁄₈
"
(35.9 cm)
43
⁷⁄₁₆
"
(110.3 cm)
17
⁵⁄₁₆
"
(44.0 cm)
22"
(55.9 cm)
2
³⁄₄
"
(7.0 cm)
2"
(5.1 cm)
¹⁵⁄₁₆
" (2.4 cm)
dia.
⁷⁄₃₂
" (5.6 mm)
dia.
35
⁵⁄₈
"
(90.5 cm)
2
³⁄₁₆
"
(5.6 cm)
47
¹³⁄₁₆
"
(121.4 cm)
20
¹⁄₄
"
(51.4 cm)
centerline
³⁄₄
"
(19.1 mm)
7
⁷⁄₈
"
(20.0 cm)
5
¹⁵⁄₁₆
"
(15.1 cm)
48" (121.9 cm) model
9
³⁄₈
"
(23.8 cm)
15
⁵⁄₈
"
(39.7 cm)
31
⁷⁄₁₆
"
(79.9 cm)
17
⁵⁄₁₆
"
(44.0 cm)
22"
(55.9 cm)
2
³⁄₄
"
(7.0 cm)
2"
(5.1 cm)
¹⁵⁄₁₆
" (2.4 cm)
dia.
⁷⁄₃₂
" (5.6 mm)
dia.
27
¹⁄₂
"
(69.9 cm)
2
³⁄₁₆
"
(5.6 cm)
35
¹³⁄₁₆
"
(91.0 cm)
14
³⁄₁₆
"
(36.0 cm)
centerline
³⁄₄
"
(19.1 mm)
7
⁷⁄₈
"
(20.0 cm)
5
¹⁵⁄₁₆
"
(15.1 cm)
36" (91.4 cm) model
9
³⁄₈
"
(23.8 cm)
9
³⁄₈
"
(23.8 cm)
90° elbow
wall cap
1 — 90° elbow = 5 ft. (1.5 m)
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
1 — wall cap = 0 ft. (0 m)
system length = 13 ft. (3.9 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
Example vent
system
Vent piece 6" (15.2 cm) round or
10" (25.4 cm) round
45° elbow 2.5 feet
(0.8 m)
90° elbow 5.0 feet
(1.5 m)
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
Maximum equivalent vent length is 35 feet (10.7 meters) for 6" (15.2 cm) vent, 60 feet (18.3 m) for 10" (25.4 cm) vent.
The 36" (91.4 cm) model requires a 6" (15.2 cm) round vent system for installation (not included). The 48" (121.9 cm) model requires two 6" (15.2 cm) round vent systems or a 10" (25.4 cm) round vent system for installation. The hood exhaust opening is 6" (15.2 cm) round.