30 and 36 Range Hoods
PRODUCT MODEL NUMBERS
KHTU705R KHTU765R
KHTU705S KHTU765S
Electrical: 120-V, 60-Hz, AC-only, 15 amp. electrical supply. Use copper wire only. A time­delay fuse or circuit breaker and separate circuit is recommended.
INSTALLATION CLEARANCES
30”(76.2 cm) or
36” (91.4 cm) min.
cabinet opening width
24” (61 cm) min.
30” (76.2 cm) suggested max. bottom of hood
to cooking surface
18” (45.7 cm) min. clearance upper cabinet to countertop
36” (91.4 cm)
countertop
height
70 ⁵⁄₁₆"
(178.6 cm)
min.
76 ⁵⁄₁₆"
(193.8 cm)
max.
to bottom of
cabinet frame
OVERALL DIMENSIONS
5 ⁷⁄₈" (14.9 cm) dia.
exhaust collar
Interchangeable
9 ¹⁵⁄₁₆"
(25.2 cm)
20 ³⁄₁₆
(51.3 cm)
front trim
29 ¹⁵⁄₁₆” (76.0 cm) - 30” (76.2 cm) model 35 ¹⁵⁄₁₆” (91.3 cm) - 36” (91.4 cm) model
VENT AND ELECTRICAL OPENINGS AND MOUNTING SCREW LOCATIONS
(3.2 cm)
1⁵⁄₁₆
(3.3 cm)
1¹⁄₄
1⁵⁄₁₆
(3.3 cm)
Electrical knockouts
5⁷⁄₈
(14.9 cm)
dia.
Centerline of exhaust collar
7¹⁄₂
(19.0 cm)
Centerline of
hood
9¹⁄₈
(23.2 cm)
1³⁄₁₆
(3.0 cm)
3⁵⁄₁₆
(10.0 cm)
VENTING REQUIREMENTS
This range hood is factory set for vented installations. Vent system can terminate through either the roof or a wall. The vent system length should not exceed 35 ft (10.7 m)
It is recommended that you use round vent instead of rectangular vent, especially if elbows are required.
For best performance, use no more than three 90° elbows. If more than one elbow is used, make sure that there is a minimum of 24 inches (61 cm) of straight vent between any two elbows. Do not install two elbows together.
To calculate the length of system you need, add the equivalent
feet (meters) from chart below for each vent piece that will be needed.
Determine the length of the vent system you need
To calculate the length of the vent system you need, add the equivalent feet (meters) from chart below for each vent piece that will be needed.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifi cations without notice.
Recommended standard 6(15.2 cm) fi ttings
1 ft. round= 1 ft. (0.3 m)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifi cations subject to change without notice.
90° elbow= 5 ft. (1.5 m)
45° elbow=
2.5 ft. (0.8 m)
Ref. 9763384 09-11-06