PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
VENTING REQUIREMENTS
KHMS105B
KHMS105E
KHMC107E
Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20amp. electrical supply located in the upper cabinet
as close as possible to the microwave oven hood.
A time-delay fuse or circuit breaker and separate
circuit is recommended.
Microwave Oven Hood Combination
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 4359330
09-17-02
Roof venting
Wall venting
This product is suitable
for use above electric
and gas cooking
products 30" wide
or less.
29-7/8"
13-7/8"
30" min. to top of wall
mounting bracket
30" min. cabinet
opening width
16"
CRITICAL
DIMENSION
14" min. to cooking
surface or countertop
Recommended standard fittings
If the existing duct is round, a rectangularto-round adapter must be used and a
rectangular 3" extension duct between the
damper assembly and the adapter must be
installed to prevent sticking of the exhaust
damper.
1 - 3-1/4" x 10"
90° elbow = 25 ft.
1 - wall cap = 40 ft.
8 feet straight = 8 ft.
Length of
3-1/4" x 10" system = 73 ft.
6" duct system
3-1/4" x 10" duct system
1 - transition = 5 ft.
2 - 90° elbows = 20 ft.
1 - wall cap = 40 ft.
8 feet straight = 8 ft.
Length of 6" system = 73 ft.
3-1/4" x 10"
90° elbow
90° elbows
transition
wall cap
6 ft.
2 ft.
6 ft.
2 ft.
3-1/4" x 10"
to 6" = 5 ft.
3-1/4" x 10"
roof cap = 24 ft.
3-1/4" x 10"
90° elbow = 25 ft.
90° elbow
= 10 ft.
3-1/4" x 10"
wall cap =
40 ft.
3-1/4" x 10"
flat elbow =
10 ft.
45° elbow
= 5 ft.
Recommended duct length
Use 3-1/4" x 10" or 6" duct.The total length
of the duct system including straight duct,
elbow, transitions, wall or roof caps must
not exceed the equivalent of 140 feet of 31/4" x 10" rectangular or 6" diameter round
duct. For best performance, use no more
than three 90° elbows.To calculate the
length of system you need, add the
equivalent feet for each duct piece used in
the system. See examples at right.
Use metal ductwork only. Rigid metal
ductwork is recommended.
Flexible metal ductwork is Not recommended.
If flexible metal ductwork is used, calculate
each foot of flexible metal ductwork as two
feet of straight metal ductwork.Flexible metal
elbows count twice as much as standard
elbows.
Determine which venting method (roof-venting
or wall-venting) you need to use.
This microwave oven hood is equipped for
ventless (recirculating) installation.
The length of the ductwork and number of
elbows should be kept to a minimum to
provide efficient performance.The size of
ductwork should be uniform. Do Not install
two elbows together.Use duct tape to seal all
joints in the duct system. Use caulking to seal
exterior wall or roof opening around cap.
®