KitchenAid KHMC107EBT, KHMC107EAL, KHMC107EBL, KHMC107E, KHMC107EWH Dimension Guide

...
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
VENTING REQUIREMENTS
KHMS105B KHMS105E
KHMC107E
Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20­amp. electrical supply located in the upper cabinet as close as possible to the microwave oven hood. A time-delay fuse or circuit breaker and separate circuit is recommended.
Microwave Oven Hood Combination
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 4359330
09-17-02
Roof venting
Wall venting
This product is suitable for use above electric and gas cooking products 30" wide or less.
29-7/8"
13-7/8"
30" min. to top of wall
mounting bracket
30" min. cabinet
opening width
16"
CRITICAL DIMENSION
14" min. to cooking surface or countertop
Recommended standard fittings
If the existing duct is round, a rectangular­to-round adapter must be used and a rectangular 3" extension duct between the damper assembly and the adapter must be installed to prevent sticking of the exhaust damper.
1 - 3-1/4" x 10"
90° elbow = 25 ft. 1 - wall cap = 40 ft. 8 feet straight = 8 ft. Length of 3-1/4" x 10" system = 73 ft.
6" duct system
3-1/4" x 10" duct system
1 - transition = 5 ft.
2 - 90° elbows = 20 ft.
1 - wall cap = 40 ft.
8 feet straight = 8 ft.
Length of 6" system = 73 ft.
3-1/4" x 10" 90° elbow
90° elbows
transition
wall cap
6 ft.
2 ft.
6 ft.
2 ft.
3-1/4" x 10" to 6" = 5 ft.
3-1/4" x 10" roof cap = 24 ft.
3-1/4" x 10" 90° elbow = 25 ft.
90° elbow = 10 ft.
3-1/4" x 10" wall cap = 40 ft.
3-1/4" x 10" flat elbow = 10 ft.
45° elbow = 5 ft.
Recommended duct length
Use 3-1/4" x 10" or 6" duct.The total length of the duct system including straight duct, elbow, transitions, wall or roof caps must not exceed the equivalent of 140 feet of 3­1/4" x 10" rectangular or 6" diameter round duct. For best performance, use no more than three 90° elbows.To calculate the length of system you need, add the equivalent feet for each duct piece used in the system. See examples at right.
Use metal ductwork only. Rigid metal ductwork is recommended.
Flexible metal ductwork is Not recommended. If flexible metal ductwork is used, calculate each foot of flexible metal ductwork as two feet of straight metal ductwork.Flexible metal elbows count twice as much as standard elbows.
Determine which venting method (roof-venting or wall-venting) you need to use. This microwave oven hood is equipped for ventless (recirculating) installation.
The length of the ductwork and number of elbows should be kept to a minimum to provide efficient performance.The size of ductwork should be uniform. Do Not install two elbows together.Use duct tape to seal all joints in the duct system. Use caulking to seal exterior wall or roof opening around cap.
®
Loading...