DRYER SAFETY .............................................................................. 3
INSTALLATION INSTRUCTIONS .................................................. 5
Tools and Parts ............................................................................ 5
Options ......................................................................................... 5
Location Requirements ................................................................ 6
Electrical Requirements ............................................................... 7
Gas Supply Requirements ........................................................... 8
Venting Requirements .................................................................. 9
Plan Vent System ....................................................................... 10
Install Vent System ..................................................................... 11
Make Gas Connection ............................................................... 11
Connect Vent .............................................................................. 12
Level Dryer ................................................................................. 12
Complete Installation ................................................................. 12
DRYER USE .................................................................................. 13
Starting Your Dryer ..................................................................... 13
Stopping Your Dryer .................................................................. 14
Pausing or Restarting ................................................................. 14
Control Locked ........................................................................... 14
Drying and Cycle Tips ................................................................ 14
Status Display ............................................................................ 14
Cycles ......................................................................................... 15
Additional Features .................................................................... 16
Temperature ............................................................................... 17
Drying Rack ................................................................................ 17
DRYER CARE .............................................................................. 18
Cleaning the Dryer Location ...................................................... 18
Cleaning the Lint Screen ............................................................ 18
Cleaning the Dryer Interior ......................................................... 18
Cleaning the Dryer Exterior ........................................................ 18
Removing Accumulated Lint ...................................................... 19
Vacation and Moving Care ......................................................... 19
TROUBLESHOOTING .................................................................. 19
ASSISTANCE OR SERVICE ......................................................... 21
WARRANTY .................................................................................. 22
SECURITE DE LA SECHEUSE .................................................... 23
INSTRUCTIONS D'INSTALLATION ............................................. 25
Outillage et pieces ...................................................................... 25
Options ....................................................................................... 25
Exigences d'emplacement ......................................................... 26
Specifications electriques .......................................................... 27
Specifications de I'alimentation en gaz ..................................... 28
Exigences concernant I'evacuation ........................................... 29
Planification du syst_me d'evacuation ...................................... 31
Installation du systeme d'evacuation ......................................... 32
Raccordement au gaz ................................................................ 32
Raccordement du conduit d'evacuation ................................... 33
Mise a niveau de la secheuse .................................................... 33
Achever I'installation .................................................................. 33
UTILISATION DE LA SECHEUSE ................................................ 34
Mise en marche de lasecheuse ................................................ 34
ArrGt de la secheuse ................................................................... 35
Pause ou remise en marche ....................................................... 35
Verrouillage des commandes ..................................................... 35
Conseils pour le sechage et les programmes ........................... 35
Temoins de I'etat d'avancement ................................................ 36
Programmes ............................................................................... 36
Caracteristiques supplementaires ............................................. 37
Temperature ............................................................................... 38
Grille de sechage ........................................................................ 38
ENTRETIEN DE LA SECHEUSE ................................................. 39
Nettoyage de I'emplacement de la secheuse ........................... 39
Nettoyage du filtre a charpie ...................................................... 39
Nettoyage de I'interieur de la secheuse ..................................... 40
Nettoyage de I'exterieur de la secheuse .................................... 40
Retrait de la charpie accumulee ................................................ 40
Precautions a prendre pour les vacances et avant un
demenagement .......................................................................... 40
DC:PANNAGE ................................................................................. 41
ASSISTANCE OU SERVICE ......................................................... 42
GARANTI E..................................................................................... 43
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
In the State of Massachusetts, the following installation instructions apply: [] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T-handle type. [] A flexible gas connector, when used, must not exceed 3 feet.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry- cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving. [] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
SAVE THESE INSTRUCTIONS
[] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
[] Clean lint screen before or after each load. [] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See installation instructions for grounding requirements.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSi Z223.1/NFPA 54 or the Canadian Natural Gas and Propane installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
INSTALLATION INSTRUCTIONS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Flat-blade screwdriver Caulking gun and
#3 Phillips screwdriver new exhaust vent)
8" or 10" pipe wrench Tin snips (new vent
8" or 10" adjustable installations) wrench (for gas _A"nut driver or socket
connections) wrench (recommended)
%6" (14 mm) open-end Pipe-joint compound wrench (for adjusting dryer
feet) resistant to LP gas
Level Pliers
Vent clamps Tape measure
Parts Supplied Remove parts packages from dryer drum. Check that all parts are
included.
A. Door handle B. Plastic washers (2)
C. Screws (2)
compound (for installing
For close-clearance installations between 33" (83.8 cm) and 38" (96.5 cm), see "Plan Vent System" section for venting requirements.
I_- 38"--_1
(96.5 cm)
Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please refer to the "Assistance
or Service" section of this manual.
Mobile Home Installation Kit. Ask for Part Number 346764.
Metal exhaust system hardware.
Pedestal
Are you placing the dryer on a pedestal? You may purchase a pedestal separately for this dryer. This pedestal will add about 11" (27.9 cm) to the height of your dryer for a total height of approximately 53" (134.6 cm).
For a garage installation, you will need to place the pedestal at least 7" (17.8 cm) above the floor.
Remove Decorative Mat
Remove the optional decorative mat (included) from the top of the dryer and set aside.
Attach Door Handle
1. Insert the 2 screws through the holes in the door.
2. Place the plastic washers onto the screws.
3. Attach the handle by hand tightening the screws, first the top then the bottom.
4
4.
Push the handle against the door. Using a Phillips screwdriver, tighten the screws.
NOTE: Do not overtighten.
Parts needed Check local codes and with gas supplier. Check existing gas
supply, electrical supply and venting. Read "Electrical Requirements," "Gas Supply Requirements" and "Venting Requirements" before purchasing parts.
Optional pedestal
To order, call the dealer from whom you purchased your dryer or refer to the "Assistance or Service" section of this manual. Ask
for Part Number LAV2701RSS.
Door Reversal Kit
Would you like to change your dryer door swing from a right-side opening to a left-side opening? To do so, you will need to purchase a Door Reversal Kit.
To order, call the dealer from whom you purchased your dryer or refer to the "Assistance or Service" section of this manual. Ask
for Part Number 8182652.
ExplosionHazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. Clothes dryers must be exhausted to the outdoors. See "Venting Requirements."
A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total dryer weight of 250 Ibs (113.4 kg). The combined weight of accessories, clothes loads and companion appliances should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.
For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor. If using a pedestal, you will need an additional 7" (17.8 cm).
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.
Installation spacing
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides, front and rear. Recommended spacing should be considered for the following reasons:
The location must be large enough to allow the dryer door to open fully.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
Companion appliance spacing should also be considered.
NOTE: This dryer cannot be stacked on the washer. Dryer Dimensions
I_ 57"
*Includes the door handle
** Includes the feet extended 1" (2.5 cm). The optional decorative
mat (included) will add approximately 1/2"(1.3 cm) to the height.
NOTE: Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements."
Recommended installation spacing for custom undercounter installation, dryer only
42"rnin.I I I I _( _ II I I
(2.Sore) ' ' (68.6crn)'
Recommended installation spacing for recessed or closet installation, with or without a pedestal
[] For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
m
48 in.2._
(310crn2)
\_j u
24irt.2._
(155crn2)
1"-_11_-27"-_1_. - 1"
(2.5 cm)
{68.8crn) {2.Scrn) (2.Scrn) {33.8crn) (12.7crn)
Ii"_ 33"_.1s,,I
A B
A. Front view B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Recommended installation spacing for cabinet installation, with or without a pedestal
[] For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
7"* (17.8cm)
7"* (17.8crn)
,I,
_f 3"*
{7.6 crn)
3,,*
(7.6cm/
+
Mobile home installations require:
[] Metal exhaust system hardware, which is available for
purchase from your dealer.
[] Mobile home Installation Kit Part Number 346764. See "Tools
and Parts" section for ordering information. Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong.
Do not use an adapter. Do not use an extension cord,
Failure to follow these instructions can result in death,
fire, or electrical shock.
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that aseparate circuit serving only this dryer be provided.
GROUNDING iNSTRUCTiONS
CCC)
1" 27" 1"
(2.5 crn) (68.6 crn) (2.5 cm) (12.7 crn) (88.8 crn) (2.5 crn)
5" 33" 1"
A B
A. Front view B. Side view C. Cabinet with vents
*Required spacing
Mobile home - Additional installation requirements This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard
CAN/CSA-Z240 MH.
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut=off valve. Securely tighten all gas connections.
if connected to LP, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate
in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or
call the phone numbers referenced in the "Assistance or Service" section of this manual.
LP gas conversion: Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
Must include a shutoff valve: In the U.S.A.: An individual manual shutoff valve must be installed within
six (6)feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1.
In Canada: An individual manual shutoff valve must be installed in
accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) feet (1.8 m) of the dryer.
The location should be easy to reach for opening and closing.
A C E
B D
A. %" flexible gas connector
B. %" pipe to flare adapter fitting C. Vs"NPT minimum plugged tapping D. Y2"NPT gas supply line
E. Gas shutoff valve
Gas supply connection requirements
Use an elbow and a %" flare x 3/8"NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON °t tape.
This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24.
Burner input requirements
Elevations above 2,000 ft (600 m):
When installed above 2,000 ft (600 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (300 m) above sea level.
Gas supply line
Must include r/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).
r/2" IPS pipe is recommended.
%" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.
If you are using Natural gas, do not use copper tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.
If your dryer has been converted to use LP gas, %" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON °t tape.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than 1/2psi.
_TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Dryer gas pipe
If this is a new vent system
The gas pipe that comes out through the rear of your dryer has a %" male pipe thread.
A
21_6 ''*
(7.1 cm)
I _ (12"4"cm)
A. 7/p,,NPT gassupply line B. _" NPT dryerpipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 11" (28 cm) from the floor. For a garage installation, the gas pipe height must be an additional 18" (46 cm) from the floor.
Fire Hazard
Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death
or fire.
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFF Mventing products are recommended.
4" (10.2 cm)heavy metal exhaust vent
DURASAFF Mvent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the "Assistance or Service" section of
this manual.
Rigid metal vent
For best drying performance, rigid metal vents are recommended.
Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for cleaning and the total length does not exceed 8 ft (2.4 m).
Flexible metal vent must be fully extended and supported when the dryer is in its final location.
Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.
Do not install flexible metal vent in enclosed walls, ceilings or floors.
Elbows
45° elbows provide better airflow than 90° elbows.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid metal vent.
Review Vent system charts. Modify existing vent system if necessary to achieve the best drying performance.
Good Better
Clamps
Use clamps to seal all joints. Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the duct. Do not use duct tape.
Clamp
Exhaust
Recommended hood styles are shown here.
_. (l:4"!rn)
(10.2 cm)
A.Louvered hood style B.Boxhood style
The angled hood style (shown here) is acceptable.
4"
Choose your exhaust installation type
Recommended exhaust installations
This dryer vents from the rear of the dryer.
B
A ........ I
................. F
..................................e
(10.2 cm)__
An exhaust hood should cap the vent to keep rodents and insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
improper venting can cause moisture and lint to collect indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
A. Dryer
B. Elbow C. Wall D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to
connect elbows
H. Exhaust outlet
Alternate installations for close clearances
Venting systems come in many varieties, Select the type best for your installation. One close-clearance installation is shown, Refer to the manufacturer's instructions, Refer to Vent system chart 2 for vent length and elbows needed for best drying performance,
x, 4....
Over-the-top installation (also available with one offset elbow)
NOTE: The following kit for close clearance alternate installations is available for purchase. Please see the "Assistance or Service"
section of this manual to order.
Over-the-Top Installation: Part Number 4396028
10
Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90 ° turns possible.
Determine vent length and elbows needed for best drying performance
Use one of the following Vent system charts to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system charts. Exhaust systems longer than those
specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system charts provide venting requirements that will help to achieve the best drying performance.
Vent system chart 1 - rigid metal vent only
Number of Type of Box or Angled
90° turns vent Iouvered hoods or elbows hoods
0 Rigid metal 174 ft (53.0 m) 168 ft (51.2 m)
1 Rigid metal 164 ft (50.0 m) 158 ft (48.0 m) 2 Rigid metal 154 ft (46.9 m) 148 ft (45.1 m) 3 Rigid metal 145 ft (44.2 m) 139 ft (42.4 m)
4 Rigid metal 137 ft (41.8 m) 131 ft (39.9 m)
Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
1. Position the dryer so that the rear of the dryer is within 4 ft (1.2 m) of its final location.
2. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.
3. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
4. Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in "Plan Vent System." Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior
of the vent to secure vent.
1.
Remove the blue cap from the gas pipe. Move the dryer close to its final location.
2.
Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound on all non-flared male threads. Ifflexible metal tubing is used, be sure there are no
kinks. NOTE: For LP gas connections, you must use pipe-joint
compound resistant to the action of LP gas. Do not use TEFLON _ttape.
A combination of pipe fittings must be used to connect the dryer to the existing gas line. Shown following is a
recommended connection. Your connection may be different, according to the supply line type, size and location.
Vent system chart 2 - rigid metal vent used with a maximum of 8 ft (2.4 m) flexible metal vent
Number of Type of Box or Angled g0° turns vent Iouvered hoods
or elbows hoods 0 Rigid metal t44 ft (43.9 m) 138 ft (42.1 m)
1 Rigid metal 134 ft (40.8 m) 128 ft (39.0 m)
2 Rigid metal 125 ft (38.1 m) 119 ft (36.3 m) 3 Rigid metal 117 ft (35.7 m) 111 ft (33.8 m)
B
A. _" flexible gas connector B. _" dryer pipe
C. _" to _" street el D. _" pipe-to-flare adapter fitting
3.
Open the shutoff valve in the supply line. The valve is open
a
when the handle is parallel to the gas pipe.
A. Closed valve B. Open valve
4. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
1@TEFLON isa registered trademark of E.I. Du Pont De Nemoursand Company.
11
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. Check that there are no kinks in the flexible gas line.
All four dryer feet were preset to the same height at the factory.
1. Using a 9/16"(14 mm) open-end wrench, verify that the nuts on the two rear preset feet are tightened against the cabinet.
2. Slide the dryer to its final location.
3. Check the levelness of the dryer. Check levelness first side to side, then front to back.
1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Check the dryer's final location. Be sure the vent is not crushed or kinked.
4. Check that the dryer is level. See "Level Dryer."
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
4. If the dryer is not level, move the dryer slightly away from the wall and first prop the front with a wood block and adjust the
feet as necessary; then prop the back and adjust feet as necessary. Repeat this step until dryer is level.
5. After the dryer is level, use a 9/16"(14 mm) open-end wrench to turn the nuts on the feet tightly against the dryer cabinet.
5. Plug into a grounded 3 prong outlet. Turn on power.
6. Remove any protective film or tape remaining on the dryer.
7. Dispose of/recycle all packaging materials.
8. Set the decorative mat in place on top of the dryer, if desired. NOTE: Check that the top of the dryer and the bottom of the
mat are clean.
9. Read "Dryer Use."
10. Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.
11. Select a Timed Dry heated cycle, and start the dryer. Do not select the Air Only Temperature setting.
If the dryer will not start, check the following:
Dryer is plugged into a grounded 3 prong outlet.
Electrical supply is connected.
Household fuse is intact and tight, or circuit breaker has
not tripped.
Dryer door is closed.
12. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close door. If you do not feel heat, turn off the dryer and check that the gas supply line shutoff valve is open.
If the gas supply line shutoff valve is closed, open it, then
repeat the 5-minute test as outlined above.
If the gas supply line shutoff valve is open, contact a
qualified technician.
12
!
DRYER USE
_0 Extra High
0 High
0 Medium
0 Low
0 Extra Low
OAir Only
Estimated Time
Remaining Status
j O Soft
Oi _70off
_O Loud
Touch Rapid
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer. Do not dry anything that has ever had anything
flammable on it (even after washing).
Failure to follow these instructions can result in death,
explosion, or fire.
©
TEMP
No washer can completely remove oil. Do not dry anything that has ever had any type of oil on
it (including cooking oils). Items containing foam, rubber, or plastic must be dried
on a clothesline or by using an Air Cycle. Failure to follow these instructions can result in death
or fire.
@ O
EXTRA CARE CYCLE END
TONE
Fire Hazard
Follow these basic steps to start your dryer. Please refer to specific sections of this manual for more detailed information.
f. Clean lint screen before each load, See "Cleaning the Lint
Screen."
2. Place laundry into dryer and shut door.
3. Select either an Automatic or Manual cycle by pressing the desired cycle button, The preset settings and drying time for the chosen cycle will be displayed.
To use an Automatic Cycle
Select an Automatic Cycle. Select DRYNESS LEVEL to adjust how dry you want the
load. As the cycle runs, the control senses the dryness of the load and adjusts the time automatically for the selected dryness level.
To make changes during an Automatic Cycle:
Press PAUSE/CANCEL once.
Adjust Dryness Level. NOTE: Dryness Level selections can be made only while
using Automatic Cycles. Selecting More or Less automatically adjusts the sensed time needed.
nnWiFL -- O Normal
DRY_E!SS O _[ O M°re
O Less
13
To use a Manual Cycle
Select a Manual Cycle. Press the plus (+) or minus (-) key until the desired drying time
is displayed. Press plus (+) or minus (-) and the time will change by 1-minute intervals. Press and hold plus (+) or minus (-) and the time will change by 5-minute intervals.
NOTE: The plus (+) or minus (-) features can be used only with Manual Cycles.
Press TEMP until the desired temperature illuminates. NOTE: During a Manual Cycle, you can change the settings
for Time, Temperature, Extra Care and Cycle End Tone signal. Press PAUSE/CANCEL twice to stop the dryer and clear the settings. Select another cycle or option.
4.
(OPTIONAL STEP) If desired, set the Cycle End Tone signal. Select LOUD or SOFT to alert you when a cycle ends.
5.
Press and hold START for approximately 3 seconds until dryer starts. Be sure the door is closed.
If you do not press Start within 5 minutes of selecting the
cycle, the dryer automatically shuts off.
If you wish to end your drying cycle after pressing Start,
press PAUSE/CANCEL twice.
To stop your dryer at anytime Press PAUSE/CANCELtwice or open the door.
To pause the dryer at any time
Open the door or press PAUSE/CANCEL once.
To restart the dryer
Close the door. Press and hold START until dryer starts. NOTE: Drying will continue from where the cycle was interrupted
if you close the door and press Start within 5 minutes. Ifthe cycle is interrupted for more than 5 minutes, the dryer will shut off. Select new cycle settings before restarting the dryer.
Select the correct cycle and dryness level or temperature for your load. If an Automatic Cycle is running, the display shows the estimated cycle time when your dryer is automatically sensing the dryness level of your load. If a Manual Cycle is running, the display shows the exact number of minutes remaining in the cycle.
Cool Down tumbles the load without heat during the last few minutes of all cycles. Cool Down makes the loads easier to handle and reduces wrinkling. The length of the Cool Down depends on the load size and dryness level.
Drying tips
Follow care label directions when they are available.
Remove the load from the dryer as soon as tumbling stops to reduce wrinkling. This is especially important for permanent press, knits and synthetic fabrics.
Avoid drying heavy work clothes with lighter fabrics. This could cause overdrying of lighter fabrics, leading to increased shrinkage or wrinkling.
Cycle tips
Dry most loads using the preset cycle settings.
Refer to the Automatic or Manual Preset Cycle Settings chart (in the "Cycles" section) for a guide to drying various loads.
Drying temperature and Dryness Level are preset when you choose an Automatic Cycle. You can choose a different dryness level, depending on your load by pressing the DRYNESS LEVEL button to select MORE or
LESS.
If you wish to adjust the cycle length of a Manual Cycle,
you must press plus (+) or minus (-) buttons. Adjust the temperature of a Manual Cycle by pressing TEMP until the desired temperature is selected.
NOTE: You cannot choose a Dryness Level with Manual Cycles.
.... i'
Messages on the status display help you to follow the progress of your dryer.
Estimated Time
Remaining Status
This feature allows you to lock your settings to avoid unintended use of the dryer. You can also use the Control Locked feature to avoid unintended cycle or option changes during dryer operation.
To enable the Control Locked feature when dryer is running:
Press and hold the DRY RACK button for 3 seconds. The control is locked when a single beep is heard and the Control Locked
icon is displayed in the status window. The icon is located next to the Dry Rack button and will illuminate when control locked.
When the dryer is off, it is not necessary to turn the control on before activating the Control Locked feature.
To unlock:
Press and hold the DRY RACK button for 3 seconds to turn off this feature.
NOTE: When the dryer is running and Control Locked is on, the dryer can be stopped by pressing the PAUSE/CANCEL button,
but can't be restarted until the control is unlocked.
14
Wet WET is displayed at the beginning of the Automatic or Manual
Cycle if a wet item is detected.
In an Automatic Cycle, if a wet item is not detected after 5 minutes, the dryer goes directly into Cool Down. COOL
DOWN will be displayed, along with EXTRA CARE, if selected.
In a Manual Cycle, if a wet item is not detected, the dryer will continue to run for the length of time selected, but WET will not be displayed.
Damp
DAMP is displayed if the load has reached the damp dry level.
NOTE: DAMP will not be displayed with Manual Cycles.