KitchenAid KGRS206x User Manual

30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
KGRS206X KGRS208X KGRS308X
Gas supply line:
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®†tape.
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the range.
Must include a shutoff valve: The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.
Type of Gas
Natural gas:
This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. See “Gas Conversions” section. The model/serial rating plate located behind the control panel has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 316903001
9/27/11
IMPORTANT: The range must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time­delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.
Page 1 of 2
GAS SUPPLY REQUIREMENTS
ELECTRICAL REQUIREMENTS
30"
(76.2 cm)
B
A
C
A. Gas supply line B. Shutoff valve “open” position C. To ran
ge
25³⁄₄"
(65.4 cm)
48¹⁄₂"
(123.2 cm)
max
29¹⁄₄"
(74.3 cm)
36±1/8"
(91.4±0.3 cm)
(Adjustable)
29⁷⁄₈"
(75.9 cm)
max
door
closed
46⁵⁄₈"
(118.4 cm)
max
door
open
CABINET OPENING DIMENSIONS
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 316903001
9/27/11
Page 2 of 2
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Range may be installed with zero clearance to the combustible construction at the rear and on the sides below the cooktop.
Min. to cabinets on
either side of range
36"
(91.4 cm)
Std.
Recommended area for through­the-floor connection of gas pipe stub and shutoff valve.
18"
(45.7 cm)
13" (33.0 cm) Max.
*15"
(38.1 cm)
30"
(76.2 cm)
30"
(76.2 cm)
Min. height from
cooktop to cabinets
30”
11¹⁄₂"
(29.2 cm)
10¹⁄₂"
(26.7 cm)
23"
(58.4 cm)
2" (5.1 cm)
7"
(17.8 cm)
25"
(63.5 cm)
24"
(61.0 cm)
Recommended area for 120V outlet on rear of wall and area for through-the-wall connection of pipe stub and shutoff valve.
*
* 9500 BTU or less 2" (5.1 cm) 10,000 - 16,999 BTU 3" (7.6 cm) 17,000 BTU or greater 5" (12.7 cm)