KitchenAid KGCD807X Guide

30" (76.2 CM) GAS DOWNDRAFT COOKTOP
PRODUCT MODEL NUMBERS CUTOUT DIMENSIONS
KGCD807X
PRODUCT DIMENSIONS
GAS SUPPLY REQUIREMENTS
Type of Gas
Natural Gas: This cooktop is design-certified by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
This cooktop is factory set for use with Natural gas. If converting to LP gas, see the “LP Gas Conversion” instructions provided in the package containing literature. The model/serial rating plate located on the underside of the cooktop base has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP Gas Conversion: Conversion must be done by a qualified service technician. No attempt shall be made to convert the cooktop from the gas
specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See the Gas Conversion instructions provided in the package containing literature.
Gas Supply Line
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the cooktop location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®†tape. With LP gas, piping or tubing size should be ¹⁄₂" minimum. Usually, LP gas suppliers determine the size and materials used in the system.
Flexible metal appliance connector:
If local codes permit, use a ¹⁄₂" or ³⁄₄" I.D. flexible stainless steel tubing gas connector, designed by CSA to connect the cooktop to the rigid gas supply line.
ELECTRICAL REQUIREMENTS
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10305290A
8/25/10
Page 1 of 2
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this cooktop be provided.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and
Company.
A. 28 B. 19 C. 9 D. 6 E. 2
F. Floor exhaust option
G. 6
5" (12.7 cm) vent system
H. 9
I. 13
J. Wall exhaust option
H
I
J
⁵⁄₈
" (72.7 cm) maximum
¹⁵⁄₁₆
" (21.6 cm)
⁵⁄₁₆
" (17.2 cm)
⁴⁹⁄₆₄
" (5.4 cm) minimum space to front edge of cooktop
¹⁄₈
¹⁄₈
" (15.6 cm) for 6" (15.2 cm) vent system and 5
⁵⁄₁₆
" (21.6 cm)
³⁄₈
" (33.9 cm) from the top of the countertop surface
A
B
D
C
E
F
G
¹⁄₈
" (13.1 cm) for
30" (76.2 cm) Cooktop
A
B
C
A. 21³⁷⁄₆₄" (54.8 cm) with stainless steel trim or
21½" (54.6 cm) without stainless steel trim
B. 19⁴⁷⁄₆₄" (50.1 cm) screw head to screw head
C. Model/serial rating/clearance plate location
A B
C
D
E
G
H
I
J
¹⁵⁄₁₆
A. 29
B. 30
C. 12
D. 7
" (76.1 cm) without
stainless steel trim
¹⁄₃₂
" (76.3 cm) with
stainless steel trim
" (31.6 cm) centerline of
²⁹⁄₆₄
cooktop to centerline of gas manifold pipe
⁵⁄₁₆
" (18.6 cm)
" (9.2 cm)
E. 3
³⁹⁄₆₄
F. 15" (38.1 cm)
" (5.5 cm) recommended
⁵⁄₃₂
G. 2
minimum cabinet to motor clearance
" (36.4 cm)
¹¹⁄₃₂
H. 14
⁴⁹⁄₆₄
" (29.9 cm)
I. 11
J.
28³⁄₈
" (72.1 cm) screw head to
screw head
F
CABINET DIMENSIONS
NOTES: After making the countertop cutout, some installations may require
notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.
A minimum side clearance of 6" (15.2 cm) is recommended between side of cooktop and side wall for maximum ventilation performance.
A minimum clearance of 2" (5.1 cm) is recommended between the motor/blower and cabinet for proper cooling. A 6" (15.2 cm) clearance is recommended for servicing access.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10305290A
8/25/10
Page 1 of 2
A
D
C
N
B
L
E
F
G
H
M
K
I
K
J
M
A. 30" (76.2 cm) B. Combustible area above countertop (shown by dashed box above) C. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet (24" [61.0 cm] minimum clearance if bottom of wood or metal cabinet is covered by not less than ¼" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33.0 cm) recommended upper cabinet depth
¹⁄₈
" (5.4 cm)
E. 2
¹⁵⁄₁₆
" (50.6 cm)
F. 1 9
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of
countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of
cabinet
⁵⁄₈
" (72.7cm) on 30" (76.2 cm) models
J. 28 K. 8" (20.3 cm) minimum distance to nearest left and right side
combustible surface above cooktop
L. 2" (5.1 cm) minimum clearance between back wall and countertop
M. Gas line opening - Wall: anywhere 6" (15.2 cm) below underside of
countertop on the left side. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall on the left side is recommended.
N. 25" (63.5 cm) depth of countertop
Loading...