![](/html/51/51fd/51fd60cb2741924f86f240e4fa80b417e34f6f3774dc3cd9ba788a8365449200/bg1.png)
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
Gas Built-in Cooktop
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
®
IMPORTANT: If installing a range hood or microwave hood
combination above the cooktop, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
NOTES: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear the
cooktop base. To avoid this modification, use a base cabinet with
sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened to
avoid interfering with the regulator.
TYPE OF GAS
KGCC506R
KGCC566R
KGCK306V
KGCK366V
Metal Cooktops
A
Natural Gas:
●
This cooktop is factory set for use with Natural gas.
If converting to LP gas, see the following “LP Gas
Conversion” section. The model/serial rating plate
located on the underside of the cooktop base has
information on the types of gas that can be used. If
the types of gas listed do not include the type of gas
available, check with the local gas supplier.
Straight-edge glass cooktops
B
LP Gas Conversion:
Conversion must be done by a qualified service
technician.
A
No attempt shall be made to convert the cooktop
from the gas specified on the model/serial rating
plate for use with a different gas without
consulting the serving gas supplier. See the Gas
Conversion instructions provided in the package
containing literature.
Electrical: A 120-volt, 60-Hz, AC-only, 15-amp
Curved-edge glass cooktops
B
fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only
this cooktop be provided.
A
⁷⁄₁₆
A. 31
" (79.8 cm) on 30" (76.2 cm) models,
⁹⁄₁₆
37
" (95.4 cm) on 36" (91.4 cm) models
¹⁄₄
B. 21
" (53.4 cm)
⁷⁄₈
C. 2
" (7.3 cm)
B
C
⁵⁄₁₆
A. 20
" (51.5 cm)
³⁄₁₆
B. 30
" (76.8 cm) on 30" (76.2 cm) models,
⁷⁄₁₆
36
" (92.5 cm) on 36" (91.4 cm) models
⁷⁄₈
C. 2
" (7.3 cm)
C
¹⁄₈
A. 21
" (53.7 cm)
⁵⁄₁₆
B.30
" (77.0 cm) on 30" (76.2 cm) models,
⁵⁄₁₆
36
" (92.3 cm) on 36" (91.4 cm) models
⁷⁄₈
C. 2
" (7.3 cm)
C
A
C
M
B
K
F
E
H
L
J
I
A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models
B. Combustible area above countertop (shown by dashed box)
" (76.2 cm) minimum clearance between top of cooktop
C. 30
platform and bottom of unprotected wood or metal cabinet
(24
" [61 cm] minimum clearance if bottom of wood or metal
cabinet is protected by not less than
retardant millboard covered with not less than No. 28
D
G
J
MSG sheet steel, 0.015
0.024
" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
" (33 cm) recommended upper cabinet depth
D. 13
" (5.4 cm)
E. 2
¹⁄₈
" (48.3 cm)
F. 1 9
G. 18" (45.7 cm) minimum clearance from upper cabinet to
countertop within minimum horizontal clearances to cooktop
H. Grounded outlet - Locate within 24" (61 cm) of right rear
corner of cutout
I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models
" (21.3 cm) minimum distance to nearest left and right side
J. 8
³⁄₈
combustible surface
" (7.3 cm) minimum distance to rear combustible surface
K. 2
⁷⁄₈
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: Anywhere within
6" (15.2 cm) of rear wall is recommended
M. 24" (61 cm) minimum countertop depth is required
" [0.04 cm] stainless steel, or
" [0.6 cm] flame
¹⁄₄
Ref. W10526074B
8/10/15