KitchenAid KEWS175BSS, KEWS105BSS, KEWS175BPA Dimension Guide

WARMING OVERALL RECESSED RECESSED DRAWER WIDTH (A) WIDTH (B) HEIGHT (C) SIZE
24" 23³⁄₄"22¹⁄₄"9" (61 cm) (60.3 cm) (56.5 cm) (22.9 cm)
27" 26³⁄₄"25¹⁄₄"9" (68.6 cm) (67.9 cm) (64.1 cm) (22.9 cm)
30" 29³⁄₄"28¹⁄₄"9" (76.2 cm) (75.6 cm) (71.8 cm) (22.9 cm)
PRODUCT MODEL SERIES PRODUCT DIMENSIONS
CABINET OPENING DIMENSIONS
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this warming drawer be provided.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10513490A
7/26/12
24" (61 CM), 27" (68.6 CM), AND 30" (76.2 CM) INDOOR/OUTDOOR ELECTRIC WARMING DRAWER
ELECTRICAL CONNECTION
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and
ordinances.
Cutout dimensions that are shown must be used. Given dimensions provide minimum clearance with warming drawer.
Recessed installation area must provide complete enclosure around the recessed portion of the warming drawer.
Grounded electrical supply is required. See “Electrical Requirements” section.
Electrical supply outlet should be located in the rear wall on the upper right-hand side of the cutout or in an adjacent cabinet. The outlet must be recessed. If the electrical outlet is located in an adjacent cabinet, a 1³⁄₈" (3.5 cm) minimum diameter hole should have been drilled in the back of the cutout or support surface to pass the power supply cord through to the outlet.
Warming drawer support surface must be solid, level and flush with bottom of cabinet cutout.
Warming drawers with oiled bronze, black glass, and white glass panels are approved for indoor use only.
For best performance results make sure the warming drawer is leveled before completing installation. There is no way to level the warming drawer after it has been installed. If the installation is not level, the door may slide open or not seal tightly, allowing heat to escape.
Cabinet Side View
Cabinet Front View
o
c
WARMING CUTOUT MIN. CABINET DRAWER SIZE WIDTH (A) WIDTH (B)
24" (61 cm) 22¹⁄₂" (57.1 cm) 24" (61 cm) 27" (68.6 cm) 25¹⁄₂" (64.8 cm) 27" (68.6 cm) 30" (76.2 cm) 28¹⁄₂" (72.4 cm) 30" (76.2 cm)
Warming drawer can be installed as an indoor single or double installation or installed under a single oven. Two warming drawers under a single oven are shown.
NOTE: The warming drawer cannot be leveled after being installed. For outdoor installation follow the cutout dimensions above. Install the outdoor
warming drawer in a permanent fixture.
Custom Wood Drawer Front
If you plan to install a custom wood panel to match your cabinets, we recommend consulting a qualified cabinetmaker or carpenter. The back of the wood panel must be sealed to avoid moisture damage.
B
C
A
120 volt grounded
utlet (or located in adjacent
abinet)
Warming
drawer
cutouts
Toe
kick
2¹/" (6.4 cm) min.
9¹/" (23.2 cm)
2¹/" (6.4 cm) min.
9¹/" (23.2 cm)
Recommended 4¹/" (10.8 cm) Minimum 1" (2.5 cm)
4" (10.2 cm)
A B
Warming drawer front
22³⁄₄" (57.8 cm) recessed
oven depth
24"
(61 cm)
min. cutout
depth
Support surface must be solid, level, flush with bottom of cabinet cutout.
Loading...