Kitchenaid KEWS105BPA, KEWS175BPA Installation

INSTALLATION INSTRUCTIONS
24" (61 CM), 27" (68.6 CM), AND 30" (76.2 CM)
INDOOR/OUTDOOR ELECTRIC WARMING DRAWER
INSTRUCTIONS D'INSTALLATION
TIROIR-RÉCHAUD ÉLECTRIQUE POUR USAGE
INTÉRIEUR/EXTÉRIEUR DE
24" (61 CM), 27" (68,6 CM), ET 30" (76,2 CM)
WARMING DRAWER SAFETY ......................................................1
INSTALLATION REQUIREMENTS................................................2
Tools and Parts ............................................................................2
Location Requirements................................................................2
Electrical Requirements ...............................................................3
INSTALLATION INSTRUCTIONS..................................................4
Install Warming Drawer................................................................4
Complete Installation ...................................................................4
SÉCURITÉ DU TIROIR-RÉCHAUD ...............................................5
EXIGENCES D'INSTALLATION.....................................................6
Outillage et pièces........................................................................6
Exigences d'emplacement...........................................................6
Spécifications électriques ............................................................7
INSTRUCTIONS D'INSTALLATION...............................................8
Installation du tiroir-réchaud ........................................................8
Achever l'installation ....................................................................8
WARMING DRAWER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
follow instructions.
can be killed or seriously injured if you don't
You instructions.
follow
W10513490A
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools ne e d e d
Phillips screwdriver
Drill
1³⁄₈" (3.5 cm) hole saw
Parts supplied
4 - #8-18 x ⁵⁄₈" screws
Lens (for panel ready models)
Check local codes. Check existing electrical supply. See “Electrical Requirements.”
It is recommended that all electrical connections be made by a licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Cutout dimensions that are shown must be used. Given
dimensions provide minimum clearance with warming drawer.
Recessed installation area must provide complete enclosure
around the recessed portion of the warming drawer.
Grounded electrical supply is required. See “Electrical
Requirements” section.
Electrical supply outlet should be located in the rear wall on
the upper right-hand side of the cutout or in an adjacent cabinet. The outlet must be recessed. If the electrical outlet is located in an adjacent cabinet, a 1³⁄₈" (3.5 cm) minimum diameter hole should have been drilled in the back of the cutout or support surface to pass the power supply cord through to the outlet.
Warming drawer support surface must be solid, level and
flush with bottom of cabinet cutout.
For best performance results, make sure the warming drawer is leveled before completing installation. There is no way to level the warming drawer after it has been installed. If the installation is not level, the door may slide open or not seal tightly, allowing heat to escape.
NOTE: If installing the warming drawer below another product, refer to that product’s literature for any installation requirements.
Product Dimensions
B
C
A
WARMING DRAWER
OVERALL WIDTH (A)
RECESSED WIDTH (B)
RECESSED HEIGHT (C)
SIZE
24" (61 cm) 23³⁄₄" (60.3 cm) 22¹⁄₄" (56.5 cm) 9" (22.9 cm) 27" (68.6 cm) 26³⁄₄" (67.9 cm) 25¹⁄₄" (64.1 cm) 9" (22.9 cm) 30" (76.2 cm) 29³⁄₄"(75.6cm) 28¹⁄₄" (71.8 cm) 9" (22.9 cm)
Cabinet Dimensions
Cabinet Side View
Warming drawer front
22³⁄₄" (57.8 cm) recessed
oven depth
24"
(61 cm)
min. cutout
depth
Support surface must be solid, level, flush with bottom of cabinet cutout.
2
Cabinet Front View
o
c
120 volt grounded
utlet (or located in adjacent
abinet)
Warming
drawer
cutouts
2¹/" (6.4 cm) min.
9¹/" (23.2 cm)
2¹/" (6.4 cm) min.
9¹/" (23.2 cm)
Electrical Requirements
WARNING
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
Recommended 4¹/" (10.8 cm)
Toe kick
Minimum 1" (2.5 cm)
4" (10.2 cm)
A B
WARMING DRAWER SIZE
CUTOUT WIDTH (A)
MIN. CABINET WIDTH (B)
24" (61 cm) 22¹⁄₂" (57.1 cm) 24" (61 cm) 27" (68.6 cm) 25¹⁄₂" (64.8 cm) 27" (68.6 cm) 30" (76.2 cm) 28¹⁄₂" (72.4 cm) 30" (76.2 cm)
Warming drawer can be installed as an indoor single or double installation or installed under a single oven. Two warming drawers under a single oven are shown.
NOTE: The warming drawer cannot be leveled after being installed.
For outdoor installation, follow the cutout dimensions above. Install the outdoor warming drawer in a permanent fixture.
Custom Wood Drawer Front
If you plan to install a custom wood panel to match your cabinets, we recommend consulting a qualified cabinetmaker or carpenter. The back of the wood panel must be sealed to avoid moisture damage.
IMPORTANT: The warming drawer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this warming drawer be provided.
The model/serial rating plate is located above the left-hand
side receiving slide. The warming drawer must be removed to view the model/serial rating plate. See the following illustration.
A
A. Model/serial number plate
3
Loading...