Kitchen_kid _
INSTALLATION INSTRUCTIONS
30"(76.2 CM) FREESTANDING AND SLIDE-IN
ELECTRIC RANGES
INSTRUCTIONS D'INSTALLATION DE
CUISINIERES ELECTRIQUES AUTOPORTANTES
OU COULISSANTES DE 30"(76,2 CM)
Table of Contents/Table des matieres ............................................................................. 2
iMPORTANT:
Save for local electrical inspector's use.
iMPORTANT :
,&,conserver pour consultation par I'inspecteur local des installations electriques.
W10118260A
TABLE OF CONTENTS
TABLE DES MATIERES
RANGE SAFETY ............................................................................. 2
INSTALLATION REQUIREMENTS ................................................ 3
Tools and Parts ............................................................................ 3
Location Requirements ................................................................ 3
Electrical Requirements - U.S.A. Only ......................................... 5
Electrical Requirements - Canada Only ....................................... 6
Countertop Preparation (for Slide-in Ranges Only) ..................... 7
INSTALLATION INSTRUCTIONS .................................................. 7
Unpack Range .............................................................................. 7
Measure for Proper Height........................................................... 7
Adjust Leveling Legs .................................................................... 8
Install Anti-Tip Bracket ................................................................. 8
Electrical Connection - U.S.A. Only ............................................. 9
Verify Anti-Tip Bracket Location ................................................ 12
Level Range ................................................................................ 12
Complete Installation ................................................................. 13
Moving the Range ...................................................................... 13
ANTI-TIP BRACKET TEMPLATE ................................................ 23
SECURITr !:DE LA CUlSINIERE ................................................... 14
EXIGENCES D'INSTALLATION ................................................... 14
Outillage et pieces ...................................................................... 14
Exigences d'emplacement ......................................................... 15
Specifications de I'installation electrique ................................... 18
Preparation du plan de travail
(pour cuisinieres coulissante uniquement) ................................. 18
INSTRUCTIONS D'INSTALLATION ............................................. 19
Deballage de la cuisiniere .......................................................... 19
Mesures pour une hauteur appropriee ...................................... 19
Ajuster les pieds de nivellement ................................................. 20
Installation de la bride antibasculement .................................... 20
V_rification de I'emplacement de la bride antibasculement ......21
Reglage de I'aplomb de la cuisiniere ......................................... 21
Achever I'installation .................................................................. 22
Deplacement de la cuisini_re ..................................................... 22
GABARIT POUR LA BRIDE ANTIBASCULEMENT .................... 23
RANGE SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot,
1._ I Tip Over Hazard
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death or serious burns to children and adults.
INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
• Tape measure • Masking tape
• Flat-blade screwdriver • 1A" nut driver
• Level • %6" nut driver
• Hammer • 1/8"(3.2 mm) drill bit (for
• Hand or electric drill wood floors)
• Wrench or pliers • 3/16"(4.8 mm) carbide-tipped
• Marker or pencil concrete/ceramic floors)
Parts supplied
Check that all parts are included.
masonry drill bit (for
A
Rear Filler Strip (optional)
The rear filler strip may be used to fill a gap_'_ <. I_';_:S between the rear of
the slide-in cooktop and the wall in a freestanding cutout.
I
I
I
I
I
I jJJJ
\
A
\
B
A. Rear filler strip
B.Countertop
C.Countertop cutout
Please reference the "Assistance or Service" section of the Use
and Care guide to order.
Black - W10113902A
White - W10113903A
Biscuit - W10113904A
_C
A. Anti-tip bracket
B. Plastic anchors (2)
C. #10 x _/2"screws (2)
Anti-tip bracket must be securely mounted to subfloor.
Thickness of flooring may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed
If using a power supply cord:
• A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 1%" (3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
• A UL listed strain relief.
Check local codes. Check existing electrical supply. See
"Electrical Requirements" section.
It is recommended that all electrical connections should be made
by a licensed, qualified electrical installer.
[ "
IMPORTANT: Observe all governing codes and ordinances.
• It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located inside the oven door on
the right-hand side oven door trim.
• The range should be located for convenient use in the
kitchen.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
or microwave range hood combination that projects
horizontally a minimum of 5" (12.7 cm) beyond the bottom of
the cabinets.
• Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
• The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.
• Grounded electrical supply is required. See "Electrical
Requirements" section.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or follow local codes.
In Canada, the installation of this range must conform with the
Mobile home installations require:
• When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
• Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be
revised. See "Electrical Connection" section.
current standards CAN/CSA-A240-1atest edition, or local codes.
Product Dimensions
Freestanding Range Slide-in Range
B
A
F\ E
A. 53/4``(14.6 cm)
B. 30" (76.2 cm)
C. 413/4"(106 cm) overall height
with levering legs screwed
all the way in
D. 36" (91.4 cm) cooktop trim
height with leveling legs
screwed all the way in*
E.30" (76.2 cm)
F. 27W' (69.2 cm) max. from handle
to standoff at back of range**
G. Model/serial number plate
(located on the right-hand side
oven door trim)
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 1" (2.5 cm) beyond
24" (61 cm) base cabinet.
A. 30Wle" (77.6 cm)
B. 35%" (90.5 cm) height to
underside of cooktop edge
with leveling legs screwed
all the way in*
C. Model/serial number plate
(located on the right-hand
side oven door trim)
D. 30" (76.2 cm)
E.27_/4"(69.2 cm) from
handle to standoff at
back of range**
F. 23" (58.4 cm) countertop
notch to rear of cooktep
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 13/4'' (4.4 cm) beyond
24" (61 cm) base cabinet.
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination
installation instructions for dimensional clearances above the cooktop surface.
Freestanding Range
A freestanding range may be installed next to combustible walls
with zero clearance.
D
£
........_ii!iiiliii_
_Hiiliii iii {iiii
_iiiiii'iii]iii
\\
A. !3" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to the
top of the cooktop,
see NOTE*.
D. 30" (76.2 cm) min. opening
width
E. Junction box - 8" (20.3 cm)
to 22" (55.9 cm) from either
cabinet, 7" (!7.8 cm) max.
from floor
F. Cabinet door or hinge should
not extend into the cutout.
Slide-in Range
G
I
I
A. 13" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to
the top of the cooktop,
see NOTE*
D. 223/4'' (57.8 cm) opening
depth
E. Square cut or V4"(6.2 cm) radius
both corners
F. 30" (76.2 cm) min. opening
width
G. Junction box - 8" (20.3 cm) to
22" (55.9 cm) from either
cabinet, 7" (!7.8 cm) max. from
floor
H. Cabinet door or hinge should
not extend into cutouL
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4"(0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge is in accordance
with local codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
• Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located on the
oven frame behind the storage drawer panel. Refer to the
figures in the "Product Dimensions" section of the "Location
Requirements" section.
• Thisrangeismanufacturedwiththeneutralterminal
connectedtothecabinet.Usea3-wireULlisted,40-or50-
amppowersupplycord(pigtail)(seeRangeRatingchart
below).Iflocalcodesdonotpermitgroundthroughthe
neutral,usea4-wirepowersupplycordratedat250volts,
40or50ampsandinvestigatedforusewithranges.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8- 16.5 KW 7.8- 12.5 KW 40 or 50"*
16.6 - 22.5 KW 12.6 - 18.5 KW 50
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 1%" (34.93 mm) diameter connection opening.
• A time-delay fuse or circuit breaker is recommended.
The range can be connected directly to the fused disconnect
(or circuit breaker box) through flexible or nonmetallic
sheathed, copper or aluminum cable. See "Electrical
Connection."
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
• A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction
box).
• Wire sizes and connections must conform with the rating of
the range (40 amps).
• The wiring diagram is located on the underside of the storage
drawer or below the warming drawer in a clear plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
cabinet. The ground must be revised so the green ground wire of
the 4-wire power supply cord is connected to the cabinet. See
"Electrical Connection."
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250 volt, 40-amp, range power supply
cord (pigtail) must be used. This cord contains 4 copper
conductors with ring terminals or open-end spade terminals with
upturned ends, terminating in a NEMAType 14-50R plug on the
supply end.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire,
250 volt, 40- or 50-amp range power supply cord (pigtail). This
cord contains 3 copper conductors with ring terminals or open-
end spade terminals with upturned ends, terminating in a NEMA
Type 10-50P plug on the supply end. Connectors on the
appliance end must be provided at the point the power supply
cord enters the appliance. This uses a 3-wire receptacle of NEMA
Type 10-50R.
3-wire receptacle (10-50R)
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Be sure that the electrical connection and wire size are adequate
and in conformance with CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.
4-wire receptacle (14-50R)
• Checkwithaqualifiedelectricalinstallerifyouarenotsure
therangeisproperlygrounded.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW 7.8 - 12.5 KW 40 or 50**
16.6 - 22.5 KW 12.6 - 18.5 KW 50
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 1%" (34.9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
• Do not use an extension cord.
INSTALLATION
INSTRUCTIONS
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. Remove shipping materials, tape and protective film from the
range. Keep cardboard bottom under range. Remove oven
racks and parts package from inside oven.
2. To place range on its back, take 4 cardboard corners from the
carton. Stack one cardboard corner on top of another.
Repeat with the other 2 corners. Place them lengthwise on
the floor behind the range to support the range when it is laid
on its back. Using 2 or more people, firmly grasp the range
and gently lay it on its back on the cardboard corners.
3. Pull cardboard bottom firmly to remove.
The cooktop sides of the slide-in range fit over the cutout edge of
your countertop.
If you have a square finish (flat) countertop and the opening width
is 30" (76.2 cm), no countertop preparation is required.
Formed front-edged countertops must have molded edge
shaved flat %" (1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back %" (1.0 cm) from each
front corner and/or rounded edge flattened.
If countertop opening width is greater than 30" (76.2 cm), adjust
the %" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to
side, then front to back. If countertop is not level, range will not
be level. Range must be level for satisfactory baking conditions.
Slide-In Ranges:
1. Measure the distance of the countertop to the floor. Measure
at all 4 locations corresponding to the 4 corners of the
underside of the range cooktop, as shown.
\
Measure at locations marked A, B, C, D.
2. Measure from the floor to the underside of the range cooktop.
A. Distance from floor to underside of range cooktop
B. Range side frame
C. Cooktop
3=
Your leveling height will be the difference between the
2 measurements you have just taken.
Freestanding Ranges:
1. Measure the distance of the countertop to the floor.
2. Then measure from the top of the range cooktop trim to the
floor.
I
_J
A. Distance from the top of the range cooktop trim to the floor
3=
Your leveling height will be the difference between the
2 measurements you have just taken.
If range height adjustment is necessary, use a wrench or
pliers to loosen the 4 leveling legs.
This may be done with the range on its back or with the range
supported on 2 legs after the range has been placed back to
a standing position.
NOTE: To place range back up into a standing position, put a
sheet of cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto the cardboard or
hardboard.
__ _'_1_¸__ __ __ _ ¸_ .... __
Contact a qualified floor covering installer for the best procedure
for drilling mounting holes through your type of floor covering.
Before moving range, slide range onto shipping base, cardboard
or hardboard.
1. Remove template from the anti-tip bracket kit (found inside
the oven cavity) or from the back page of this manual.
2. Place template on the floor in cabinet opening so that the left
edge is against cabinet and top edge is against rear wall,
molding or cabinet.
3. Tape template in place.
4. If countertop is not flush with cabinet opening edge, align
template with overhang.
__- ,,
If cabinet opening is wider than specified in the "Location
Requirements" section, adjust template so range will be
centered in cabinet opening.
5=
To mount anti-tip bracket to wood floor, drill two %" (3.2 mm)
holes at the positions marked on the bracket template.
Remove template from floor.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
2=
Adjust the leveling legs to the correct height. Leveling legs
can be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of 3_6"(5 mm) is needed to engage the anti-tip
bracket.
NOTE: If height adjustment is made when range is standing,
tilt the range back to adjust the front legs, then tilt forward to
adjust the rear legs.
3=
When the range is at the correct height, check that there is
adequate clearance under the range for the anti-tip bracket.
Before sliding range into its final position, check that the anti-
tip bracket will slide under the range and onto the rear
leveling leg prior to anti-tip bracket installation.
To mount anti-tip bracket to concrete or ceramic floor, use a
3_6"(4.8 mm) masonry drill bit to drill 2 holes at the positions
marked on the bracket template. Remove template from floor.
6=
Tap plastic anchors into holes with a hammer.
7.
Align anti-tip bracket holes with holes in floor. Fasten anti-tip
bracket with screws provided.
Depending on the thickness of your flooring, longer screws
may be necessary to anchor the bracket to the subfloor.
Longer screws are available from your local hardware store.
8. Move range close enough to opening to allow for electrical
connections to be made. Remove cardboard or hardboard
from under range.
g. Make electrical connections as described in the "Electrical
Connection" section.