KitchenAid KERS807SBB User Manual

INSTALLATION INSTRUCTIONS
30" (76.2 CM) FREESTANDING AND SLIDE-IN
ELECTRIC RANGES
INSTRUCTIONS D'INSTALLATION DE
CUISINIÈRES ÉLECTRIQUES AUTOPORTANTES
OU COULISSANTES DE 30" (76,2 CM)
Table of Contents/Table des matières.............................................................................2
IMPORTANT:
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10118260A
TABLE OF CONTENTS
TABLE DES MATIÈRES
RANGE SAFETY .............................................................................2
INSTALLATION REQUIREMENTS................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................3
Electrical Requirements - U.S.A. Only......................................... 5
Electrical Requirements - Canada Only.......................................6
Countertop Preparation (for Slide-in Ranges Only).....................7
INSTALLATION INSTRUCTIONS..................................................7
Unpack Range..............................................................................7
Measure for Proper Height...........................................................7
Adjust Leveling Legs....................................................................8
Install Anti-Tip Bracket.................................................................8
Electrical Connection - U.S.A. Only............................................. 9
Verify Anti-Tip Bracket Location ................................................12
Level Range................................................................................12
Complete Installation .................................................................13
Moving the Range......................................................................13
ANTI-TIP BRACKET TEMPLATE ................................................23
SÉCURITÉ DE LA CUISINIÈRE ...................................................14
EXIGENCES D'INSTALLATION...................................................14
Outillage et pièces......................................................................14
Exigences d'emplacement.........................................................15
Spécifications de l’installation électrique...................................18
Préparation du plan de travail
(pour cuisinières coulissante uniquement).................................18
INSTRUCTIONS D'INSTALLATION.............................................19
Déballage de la cuisinière ..........................................................19
Mesures pour une hauteur appropriée ......................................19
Ajuster les pieds de nivellement.................................................20
Installation de la bride antibasculement ....................................20
Vérification de l'emplacement de la bride antibasculement......21
Réglage de l'aplomb de la cuisinière.........................................21
Achever l’installation ..................................................................22
Déplacement de la cuisinière.....................................................22
GABARIT POUR LA BRIDE ANTIBASCULEMENT....................23
RANGE SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
follow instructions.
can be killed or seriously injured if you don't
You instructions.
follow
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death or serious burns to children and adults.
2
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Rear Filler Strip (optional)
The rear filler strip may be used to fill a gap between the rear of the slide-in cooktop and the wall in a freestanding cutout.
A
B
Too ls n ee ded
Tape measure
Flat-blade screwdriver
Level
Hammer
Hand or electric drill
Wrench or pliers
Marker or pencil
Masking tape
¼" nut driver
⁵⁄₁₆" nut driver
¹⁄₈" (3.2 mm) drill bit (for
wood floors)
³⁄₁₆" (4.8 mm) carbide-tipped
masonry drill bit (for concrete/ceramic floors)
Parts supplied
Check that all parts are included.
A
B
C
A. Anti-tip bracket B. Plastic anchors (2)
C. #10 x ¹⁄₂" screws (2)
Anti-tip bracket must be securely mounted to subfloor.
Thickness of flooring may require longer screws to anchor bracket to subfloor. Longer screws are available from your local hardware store.
Parts needed
If using a power supply cord:
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening and must end in ring terminals or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See “Electrical Requirements” section.
It is recommended that all electrical connections should be made by a licensed, qualified electrical installer.
B
C
A. Rear filler strip B. Countertop C. Countertop cutout
Please reference the “Assistance or Service” section of the Use and Care guide to order.
Black - W10113902A White - W10113903A Biscuit - W10113904A
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the oven door on the right-hand side oven door trim.
The range should be located for convenient use in the
kitchen.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood or microwave range hood combination that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip Bracket” section.
Grounded electrical supply is required. See “Electrical
Requirements” section.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
3
Mobile Home - Additional Installation Requirements
C
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or follow local codes.
In Canada, the installation of this range must conform with the current standards CAN/CSA-A240-latest edition, or local codes.
Product Dimensions
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be revised. See “Electrical Connection” section.
Freestanding Range
B
A
F**
Slide-in Range
A
F
B*
D*
C
G
E**
D
E
A. 5³⁄₄" (14.6 cm) B. 30" (76.2 cm) C. 41³⁄₄" (106 cm) overall height
with leveling legs screwed all the way in
D. 36" (91.4 cm) cooktop trim
height with leveling legs screwed all the way in*
E. 30" (76.2 cm) F. 2 7 ¹⁄₄" (69.2 cm) max. from handle
to standoff at back of range**
G. Model/serial number plate
(located on the right-hand side oven door trim)
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 1" (2.5 cm) beyond 24" (61 cm) base cabinet.
4
A. 30¹¹⁄₁₆" (77.6 cm) B. 35⁵⁄₈" (90.5 cm) height to
underside of cooktop edge with leveling legs screwed all the way in*
C. Model/serial number plate
(located on the right-hand side oven door trim)
D. 30" (76.2 cm)
E. 27¼" (69.2 cm) from
handle to standoff at back of range**
F. 23" (58.4 cm) countertop
notch to rear of cooktop
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 1³⁄₄" (4.4 cm) beyond 24" (61 cm) base cabinet.
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height.
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Freestanding Range
A freestanding range may be installed next to combustible walls with zero clearance.
A
B
D
E
F
A. 13" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to the
top of the cooktop, see NOTE*.
C
D. 30" (76.2 cm) min. opening
width
E. Junction box - 8" (20.3 cm)
to 22" (55.9 cm) from either cabinet, 7" (17.8 cm) max. from floor
F. Cabinet door or hinge should
not extend into the cutout.
Slide-in Range
G
A. 13" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to
the top of the cooktop, see NOTE*.
D. 22³⁄₄" (57.8 cm) opening
depth
A
C
B
D
F
E
H
E. Square cut or ¹⁄₄" (6.2 cm) radius
both corners
F. 30" (76.2 cm) min. opening
width
G. Junction box - 8" (20.3 cm) to
22" (55.9 cm) from either cabinet, 7" (17.8 cm) max. from floor
H. Cabinet door or hinge should
not extend into cutout.
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
Electrical Requirements - U.S.A. Only
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge is in accordance with local codes.
Do not use an extension cord. Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/ NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service technician if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located on the oven frame behind the storage drawer panel. Refer to the figures in the “Product Dimensions” section of the “Location Requirements” section.
5
This range is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire UL listed, 40- or 50­amp power supply cord (pigtail) (see Range Rating chart below). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
Range Rating* Specified Rating of
Power Supply Cord Kit and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.93 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended.
The range can be connected directly to the fused disconnect
(or circuit breaker box) through flexible or nonmetallic sheathed, copper or aluminum cable. See “Electrical Connection.”
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of
the range (40 amps).
The wiring diagram is located on the underside of the storage
drawer or below the warming drawer in a clear plastic bag.
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50** 50
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the cabinet. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the cabinet. See “Electrical Connection.”
Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250 volt, 40-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50R plug on the supply end.
The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
The minimum conductor sized for the copper 4-wire power cord are:
40-amp circuit 2 No.-8 conductors 1 No.-10 white neutral 1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250 volt, 40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open­end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)
Electrical Requirements - Canada Only
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge are in accordance with local codes.
Be sure that the electrical connection and wire size are adequate and in conformance with CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.
4-wire receptacle (14-50R)
6
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
Range Rating* Specified Rating of
Power Supply Cord Kit and Circuit Protection
INSTALLATION INSTRUCTIONS
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of range’s final location.
Do not use an extension cord.
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50** 50
Countertop Preparation
(for Slide-in Ranges Only)
The cooktop sides of the slide-in range fit over the cutout edge of your countertop.
If you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.
Formed front-edged countertops must have molded edge shaved flat ³⁄₈" (1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back ³⁄₈" (1.0 cm) from each front corner and/or rounded edge flattened.
Unpack Range
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. Remove shipping materials, tape and protective film from the
range. Keep cardboard bottom under range. Remove oven racks and parts package from inside oven.
2. To place range on its back, take 4 cardboard corners from the
carton. Stack one cardboard corner on top of another. Repeat with the other 2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid on its back. Using 2 or more people, firmly grasp the range and gently lay it on its back on the cardboard corners.
3. Pull cardboard bottom firmly to remove.
Measure for Proper Height
Slide-In Ranges:
1. Measure the distance of the countertop to the floor. Measure
at all 4 locations corresponding to the 4 corners of the underside of the range cooktop, as shown.
C
A
D
30"
(76.2 cm)
30 ¾"
(78.1 cm)
If countertop opening width is greater than 30" (76.2 cm), adjust the ³⁄₈" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to side, then front to back. If countertop is not level, range will not be level. Range must be level for satisfactory baking conditions.
³⁄₈"
(1.0 cm)
B
Measure at locations marked A, B, C, D.
2. Measure from the floor to the underside of the range cooktop.
C
B
A
A. Distance from floor to underside of range cooktop B. Range side frame C. Cooktop
3. Your leveling height will be the difference between the
2 measurements you have just taken.
7
Freestanding Ranges:
1. Measure the distance of the countertop to the floor.
2. Then measure from the top of the range cooktop trim to the
floor.
A
A. Distance from the top of the range cooktop trim to the floor
3. Your leveling height will be the difference between the
2 measurements you have just taken.
Adjust Leveling Legs
1. If range height adjustment is necessary, use a wrench or
pliers to loosen the 4 leveling legs. This may be done with the range on its back or with the range
supported on 2 legs after the range has been placed back to a standing position.
NOTE: To place range back up into a standing position, put a sheet of cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto the cardboard or hardboard.
Install Anti-Tip Bracket
Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type of floor covering.
Before moving range, slide range onto shipping base, cardboard or hardboard.
1. Remove template from the anti-tip bracket kit (found inside
the oven cavity) or from the back page of this manual.
2. Place template on the floor in cabinet opening so that the left
edge is against cabinet and top edge is against rear wall, molding or cabinet.
3. Tape template in place.
4. If countertop is not flush with cabinet opening edge, align
template with overhang.
If cabinet opening is wider than specified in the “Location Requirements” section, adjust template so range will be centered in cabinet opening.
5. To mount anti-tip bracket to wood floor, drill two ¹⁄₈" (3.2 mm)
holes at the positions marked on the bracket template. Remove template from floor.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death or serious burns to children and adults.
2. Adjust the leveling legs to the correct height. Leveling legs
can be loosened to add up to a maximum of 1" (2.5 cm). A minimum of ³⁄₁₆" (5 mm) is needed to engage the anti-tip bracket.
NOTE: If height adjustment is made when range is standing, tilt the range back to adjust the front legs, then tilt forward to adjust the rear legs.
3. When the range is at the correct height, check that there is
adequate clearance under the range for the anti-tip bracket. Before sliding range into its final position, check that the anti­tip bracket will slide under the range and onto the rear leveling leg prior to anti-tip bracket installation.
To mount anti-tip bracket to concrete or ceramic floor, use a ³⁄₁₆" (4.8 mm) masonry drill bit to drill 2 holes at the positions marked on the bracket template. Remove template from floor.
6. Tap plastic anchors into holes with a hammer.
7. Align anti-tip bracket holes with holes in floor. Fasten anti-tip
bracket with screws provided.
Depending on the thickness of your flooring, longer screws may be necessary to anchor the bracket to the subfloor. Longer screws are available from your local hardware store.
8. Move range close enough to opening to allow for electrical
connections to be made. Remove cardboard or hardboard from under range.
9. Make electrical connections as described in the “Electrical
Connection” section.