KitchenAid GGE388LXQ01, GGE388LXS02, GGE390LXS02, KERS505XSS02, GGE390LXS00 Installation Guide

...
INSTALLATIONINSTRUCTIONS
FREESTANDINGELECTRICRANGEWITHDOUBLEOVENS
INSTRUCTIONSD'INSTALLATIONPOURCUISINIERE
ELECTRIQUEAUTOPORTANTEAVEC FOURSDOUBLES
Table of Contents Table des mati_res
RANGE SAFETY ......................................................................... 1
INSTALLATION REQUIREMENTS ............................................ 2
Tools and Parts........................................................................ 2
Location Requirements ............................................................ 2
Electrical Requirements - U.S.A. Only ..................................... 4
Electrical Requirements - Canada Only .................................. 5
INSTALLATION INSTRUCTIONS .............................................. 6
Unpack Range ......................................................................... 6
Adjust Leveling Legs ................................................................ 6
Install Anti-Tip Bracket ............................................................. 7
Electrical Connection - U.S.A. Only ......................................... 8
Level Range ........................................................................... 13
Moving the Range .................................................................. 14
SI_CURITI_ DE LA CUISINIERE .............................................. 16
EXIGENCES D'INSTALLATION .............................................. 17
Outils et pieces ..................................................................... 17
Exigences d'emplacement ................................................... 17
Specifications electriques - Canada seulement .................. 19
INSTRUCTIONS D'INSTALLATION ....................................... 20
Deballage de lacuisiniere ..................................................... 20
Reglage des pieds de nivellement ........................................ 20
Installation de la bride antibasculement ............................... 21
Verification de I'emplacement de la
bride antibasculement .......................................................... 22
Reglage de I'aplomb de lacuisiniere .................................... 22
Achever I'installation ............................................................. 22
Deplacement de lacuisiniere ................................................ 23
RANGESAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
,&,conserver pour consultation par I'inspecteur local des installations 61ectriques.
W10289536A
A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults.
INSTALLATIONREQUIREMENTS
s :xnd
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Tools needed
Tape measure Wrench or pliers
Level 3/8"nut driver
Phillips screwdriver Hand or electric drill
Flat-blade screwdriver 1/8"(3.2 mm) drill bit
Parts supplied Check that all parts are included.
3 - 10-32 hex nuts (attached to terminal block) 3 - Terminal lugs
Oven racks 2 - #12 x 1%" screws (for mounting anti-tip bracket)
Anti-tip bracket (taped inside upper oven with package containing literature)
Anti-tip bracket must be securely mounted to back wall or floor. Thickness of floor may require longer screws to anchor bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed If using a power supply cord:
A UL listed power supply cord kit marked for use with ranges. The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 13/8"(3.5 cm) diameter connection opening and must end in ring terminals or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See "Electrical Requirements" section.
It is recommended that all electrical connections be made by a licensed, qualified electrical installer.
Tip Over Hazard
IMPORTANT: Observe allgoverningcodes and ordinances.
ItistheinstaIIer'sresponsibilitytocomply withinstallation clearancesspecifiedon the model/serialratingplate.The modeIlserialratingplateislocatedbehindthe controlpanel.
The rangeshouldbe locatedforconvenientuse inthe kitchen.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets. Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances. The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip Bracket" section.
Grounded electrical supply is required. See "Electrical Requirements" section.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This range has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, the Standard for Manufactured Home Installations,
ANSI A225.1/NFPA 501A or with local codes. Mobile home installations require:
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards
listed above.
Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be
revised. See "Electrical Connection" section.
2
Product Dimensions
A _
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (63.5 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or
microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls with zero clearance.
F
A. 353/4'' _+%" (90.8 cm +_0.3 cm)
cooktop height (minimum) with
leveling legs screwed all the
way in*
B. Model/serial/ra ring plates
(located behind the control
panel)**
C. 47% " +1/s" (119. T cm +_O.3 cm)
overafl height (minimum) with leveling legs screwed all the
way in*
D. 281/2''_+1/4"(72.4 cm +_0.6 cm)
depth with handle E. 26%" + %" (66.4 cm +_0.3 cm)*** F. 2915/16'' + 1A6"(76.0 cm +_0.2 cm)
width
D
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**Model/serial/rating plates may be rotated up from behind the
control panel for viewing from the front of the range.
***Excludes handle. Dimension given is from wall to front of oven
door and will vary based on electric outlet receptacle
installation.
A. 18" (45.7 cm) upper cabinet
to countertop
B. 13" (33.0 cm) upper cabinet
depth
C. 30" (76.2 cm) min. opening
width.
D. For minimum clearance to the
top of the cooktop, see NOTE.
E. 30" (76.2 cm) min. opening
width
Proper positioning of outlet shown above. *Nothing located in shaded areas can extend more than lY2" (3.8 cm) from wall or range will not slide all the way back.
E Cabinet door or hinge should
not extend into cutout*
G. lY2" (3.8 cm) min. from right
side cabinet
H. 2" (5.1 cm) min. from floor
I. 7" (17.8 cm) min. from floor
J. 8" (20.3 cm) width
K. 3Y2"(8.91 cm) min. from floor
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than 1/4"(0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an unprotected wood or metal cabinet.
Ifcodespermitandaseparategroundwireisused,itis recommendedthataqualifiedelectricalinstallerdeterminethat thegroundpathandwiregaugeareinaccordancewithlocal
codes. Donotuseanextensioncord.
Besurethattheelectricalconnectionandwiresizeareadequate andinconformancewiththeNationalElectricalCode,ANSI/
NFPA70-latesteditionandalllocalcodesandordinances. Acopyoftheabovecodestandardscanbeobtainedfrom:
NationalFireProtectionAssociation OneBatterymarchPark
Quincy,MA02269. WARNING:Improperconnectionoftheequipment-grounding
conductorcanresultinariskofelectricshock.Checkwitha qualifiedelectricianorservicetechnicianifyouareindoubtasto
whethertheapplianceisproperlygrounded.Donotmodifythe powersupplycordplug.Ifitwillnotfittheoutlet,haveaproper outletinstalledbyaqualifiedelectrician.
Electrical Connection
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial/rating plate is located behind the control panel. Refer to the figures in "Product Dimensions" in the "Location Requirements" section.
This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, UL listed, 40- or
50-amp power supply cord (pigtail) (see the following Range Rating chart). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8- 16.5 KW 7.8 - 12.5 KW 40 or 50"*
16.6 - 22.5 KW 12.6 - 18.5 KW 50
If connecting to a 4-wire system:
This range ismanufactured with the ground connected to the neutral by a link. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the
cabinet. See "Electrical Connection Section." Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50P plug on the supply end.
The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power cord are:
40-amp circuit 2 No.-8 conductors
1 No.-10 white neutral 1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 13/8"(34.9 mm) diameter connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker box (or fused disconnect) through flexible or nonmetallic sheathed, copper or aluminum cable. See the "Electrical Connection - U.S.A Only." section.
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of the range.
The wiring diagram is located on the Tech Sheet.
The Tech Sheet is located on the back of the range inside a clear plastic bag.
O
3-wire receptacle (10-50R)
Electrical Shock Hazard
Electrically ground range. Failure to do so can result in death, fire, or
electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate and wire gauge are in accordance
with local codes. Be sure that the electrical connection and wire size are adequate
and in conformance with CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local codes and
ordinances. A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualified electrical installer if you are not sure the range is properly grounded.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8- 16.5 KW 7.8 - 12.5 KW 40 or 50"*
16.6 - 22.5 KW 12.6 - 18.5 KW 50 *The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 13/8"(34.9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended. This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of range's final location.
Do not use an extension cord.
INSTALLATIONINSTRUCTIONS
Excessive Weight Hazard
Use two or more people to move and install range. Failure to do so can result in back or other injury.
1. Remove shipping materials, tape and film from the range. Keep cardboard bottom under range.
2. Remove oven racks and parts package from inside oven.
3. To place range on its back, take 4 cardboard corners from the carton. Stack one cardboard corner on top of another. Repeat with the other 2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid
on its back.
4. Using 2 or more people, firmly grasp the range and gently lay it on its back on the cardboard corners.
5. Pull cardboard bottom firmly to remove.
6. Use an adjustable wrench to loosen the leveling legs.
7. Place cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto cardboard or
hardboard.
us£Le e/i
1.
If range height adjustment is necessary, use a wrench or pliers to loosen the 4 leveling legs.
This may be done with the range on its back or with the range supported on 2 legs after the range has been placed back to a standing position.
NOTE: To place range back up into a standing position, put a sheet of cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto the cardboard or
hardboard.
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death
or serious burns to children and adults.
2. Adjust the leveling legs to the correct height. Leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A minimum of 3Ae"(5.0 mm) is needed to engage the anti-tip
bracket. NOTE: If height adjustment is made when range is standing,
tilt the range back to adjust the front legs, then tilt forward to adjust the rear legs.
3. When the range is at the correct height, check that there is adequate clearance under the range for the anti-tip bracket. Before sliding range into its final location, check that the anti- tip bracket will slide under the range and onto the rear leveling leg prior to anti-tip bracket installation.
6
1. Remove the anti-tip bracket that is taped inside the upper Floor Mounting oven with the package containing literature.
2. Determine which mounting method to use: floor or wall. If you have a stone or masonry floor you can use the wall
mounting method.
3. Determine and mark edge of range in the cutout space. The mounting bracket can be installed on either the left side or right side of the cutout. Position mounting bracket in cutout so that right (or left) edge of the bracket is _%e" (2.4 cm) from the marked edge of the range, as shown.
A
B
Wall Mounting
4=
Drill two %" (3.0 mm) holes that correspond to the bracket holes of the determined mounting method. See the following.
A B
A. #12 x 1%" screws
B.Anti-tip bracket
A. #12 x 1%" screws B. Anti-tip bracket
5=
Using the Phillips screwdriver, mount anti-tip bracket to the wall or floor with the two #12 x 15/8'' screws provided.
Power Supply Cord
Direct Wire
Electrical Shock Hazard
Disconnect power before servicing. Use a new 40 amp power supply cord.
Plug into a grounded outlet. Failure to follow these instructions can result in death,
fire, or electrical shock.
1=
Disconnect power.
2.
Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range. Pull cover down and toward you to remove cover.
3.
Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.
Electrical Shock Hazard
Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range. Failure to follow these instructions can result in death,
fire, or electrical shock.
4= Add strain relief.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
A
A. UL listed strain relief
Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
8
Loading...