KITCHENAID KECC602B, KECC604B, KECC605B, KECC607B, KECC662B Dimension Guide

...
PRODUCT MODEL NUMBERS
KECC602B KECC604B KECC605B
KECC607B KECC662B KECC664B
KECC667B
Before You Make the Electrical Connection:
To properly install your cooktop, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
A 3-wire or 4-wire, single phase, 120/240 volt, 60-Hz., AC only electrical supply is required on a separate, 40-amp circuit fused on both sides of the line. The model/serial number rating plate is located on the metal cabinet underneath the cooktop. See the following illustration.
The cooktop is rated 120/240 volt. Most models have a neutral (white) wire. Model W5CE3024 does not have a neutral (white) wire.
The cooktop should be connected directly to the junction box through flexible, armored or nonmetallic sheathed, copper cable. The flexible, armored cable extending from the fuse box or circuit breaker box should be connected directly to the junction box.
Locate the junction box to allow as much slack as possible between the junction box and the cooktop so that the cooktop can be moved if servicing becomes necessary in the future.
Do not cut the conduit. Use the length of conduit provided.
A UL listed or CSA approved conduit connector must be provided at each end of the power supply cable (at the cooktop and at the junction box). A listed conduit connector is already provided at the cooktop.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.
Electric Built-in Cooktop
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10353374A
7/26/12
CABINET OPENING DIMENSIONS
IMPORTANT: If installing a range hood or microwave hood
combination above the cooktop, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.
If cabinet has a drawer, a 5¹⁄₂" (14.0 cm) depth clearance from the top of the countertop to the top of the drawer (or other obstruction) in base cabinet is required.
Page 1 of 2
A
A. Model/serial number plate
A
D
C
B
L
F
E
G
H
I
K
A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models B. Combustible area above countertop (shown by dashed box
above)
C. 30
" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered wood or metal cabinet (24
" [61 cm] minimum clearance if bottom of wood or metal
cabinet is covered by not less than millboard covered with not less than No. 28 MSG sheet steel,
0.015
" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum
" [0.05 cm] copper)
or 0.020
" (33 cm) recommended upper cabinet depth
D. 13 E. 2
" (5.1 cm)
" +/-
G. 18" (45.7 cm) minimum clearance from upper cabinet to
countertop within minimum horizontal clearances to cooktop
H. Junction box or outlet: 7" (17.8 cm) minimum from top of
countertop
I. Junction box or outlet: 9" (23.0 cm) maximum from right side of
cabinet
J. 29
¹⁄₂
" (74.9 cm) recommended cutout on 30" (76.2 cm) models. Will fit in cutout from 29 (76.2 cm) models.
¹⁄₂
" (90.2 cm) recommended cutout on 36" (91.4 cm) models.
35 Will fit in cutout from 34 (91.4 cm) models.
K. 1" (2.5 cm) minimum distance to nearest left and right side
combustible surface above cooktop
L. 1" (2.5 cm) minimum clearance between back wall and
countertop
"
(52.0 +/- 0.16 cm)
¹⁄₁₆
¹⁄₁₆
⁹⁄₁₆
"-29
"-35
⁹⁄₁₆
⁹⁄₁₆
J
[0.6 cm] flame retardant
¹⁄₄"
" (73.8-75.1 cm) on 30"
" (87.8-90.3 cm) on 36"
PRODUCT DIMENSIONS
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10353374A
7/26/12
Page 2 of 2
B
A
C
A. Glass depth - black and white models - 21
Glass depth - stainless steel models - 22
B. Glass width - 30" (76.2 cm) models - 30
Glass width - 36" (91.4 cm) models - 36 C. Frame depth - 20 D. Frame width - 30" (76.2 cm) models - 28
Frame width - 36" (91.4 cm) models - 34 E. Cooktop height - 3
F. Cooktop height including conduit (located at rear of
cooktop, right side) - 5
¹⁄₄
" (51.5 cm)
" (9.6 cm)
³⁄₄
¹⁄₄
" (13.5 cm)
³⁄₄
" (55.2 cm)
¹⁄₈
" (56.4 cm)
¹³⁄₁₆
" (78.4 cm)
⁵⁄₁₆
" (92.3 cm)
¹⁵⁄₁₆
" (73.5 cm)
⁷⁄₁₆
" (87.5 cm)
D
F
E
Loading...