KitchenAid KEBU208S, KEBU107S User Manual 2

0 (0)
Cabinet Side View -
Double or Single Oven
A. 2 B. 2 C. O D. R E. C
A
B
C
D
E
PRODUCT MODEL SERIES OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
KEBU107S KEBU208S
Electrical: Oven must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. (The model/serial number rating plate is located at the bottom of the right-hand mounting rail.) Models rated from 7.3 to 9.6 kW at 240 volts (5.5 to 7.2 kW at 208 volts) require a separate 50-amp circuit. Models rated at 7.2 kW and below at 240 volts (5.4 kW and below at 208 volts) require a separate 30-amp circuit.
A circuit breaker is recommended. Connect directly to the fused disconnect (or circuit breaker box) through flexible, armored or nonmetallic sheathed, copper cable (with grounding wire).
A cold water supply with water pressure between 30 and 120 psi (207 and 827 kPa) is required to operate the steam feature. In Massachusetts, plumbing code 248 CMR
3.00 and 10.00 must be followed. If you have questions about your water pressure call a licensed, qualified plumber.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8304535A
06-18-07
30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
®
A
E
D
A. 28
" (71.9 cm) max. recessed width
⁵⁄₁₆
C
B. 28¾" (73.0 cm) max. overall height C. 29
³⁄₄
" (75.6 cm) overall width D. 23" (58.4 cm) max. recessed depth E. 27
¹⁄₂
" (69.9 cm) recessed height
A
E
B
D
⁵⁄₁₆
A. 28
" (71.9 cm) max. recessed width
50³⁄₄
" (128.9 cm) max. overall height
B.
³⁄₄
C. 29
" (75.6 cm) overall width
D. 23" (58.4 cm) max. recessed depth
⁹⁄₁₆
" (125.9 cm) recessed height
E. 49
B
C
Single Oven Undercounter
(without cooktop installed above)
A
E
D
B
A.30" (76.2 cm) min. cabinet width
¹⁄₂
B. 1
" (3.8 cm) min. top of cutout to
underside of countertop
¹⁄₄
C. 5
" (13.3 cm) bottom of cutout to floor
¹⁄₂
" (72.4 cm) cutout width
D. 28
³⁄₄
" (70.5 cm) min. cutout height
E. 27
C
A. 24" (61.0 cm) min. cutout depth B. 23" (58.4 cm) recessed oven depth C. Oven front D. Recessed oven E. Cabinet
Single Oven Installed in Cabinet
Double Oven Installed in Cabinet
A
B
F
D
E
C
30
" (76.2 cm) min. cabinet width
A. B. 1" (2.5 cm) top of cutout to bottom of upper
cabinet door
C.
32
" (81.3 cm) bottom of cutout to floor
" (72.4 cm) cutout width
D. 28
¹⁄₂
" (3.8 cm) min. bottom of cutout to top of
E. 1
¹⁄₂
cabinet door
" (70.5 cm) cutout height
³⁄₄
F. 27
Ty pical Water Filtration System Installation Configuration
NOTE: For unique installations contact a licensed plumber.
Cold water
supply
Hot
Cold
A
B
F
E
A.30" (76.2 cm) min. cabinet width B. 1" (2.5 cm) top of cutout to bottom of upper
cabinet door
³⁄₄
" (37.5 cm) bottom of cutout to floor
C. 14
¹⁄₂
D. 28
" (72.4 cm) cutout width
¹⁄₂
" (3.8 cm) min. bottom of cutout to top of
E. 1
cabinet door
³⁄₄
F. 49
" (126.4 cm) min. cutout height
Filter assembly location
D
C