KitchenAid KDRP487M User Manual

48" Commercial Style Dual Fuel Range with self-cleaning thermal/convection oven
®
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
KDRP487M
Gas supply: Use 3/4" rigid pipe gas supply line to the range location. A smaller size pipe on long runs may result in insufficient gas supply. With L.P. gas, piping or tubing size can be 1/2" minimum. If local codes permit, it is recommended that new flexible metal tubing, design-certified by AGA or CSA, 4-5 feet long, 5/8-inch I.D., be used for connecting the range to the rigid gas supply line. A 1/2" male pipe thread is needed for connection to pressure regulator female pipe threads. An individual manual shutoff valve must be located in the same room, but external to the range.
Electrical: A four-wire or three-wire, single phase, 240-volt, 60-Hz, AC-only, electrical supply is required on a separate 50 amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8302571
12-07-04
*NOTE: 49" (124.5 cm) min. when bottom of wood or metal
cabinet is protected by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
55" (139.7 cm) min. clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
13" (33 cm) max.
upper cabinet depth
48" (121.9 cm) min. upper cabinet width
48-1/4" (122.6 cm)
opening width
20"
(50.8 cm)
12"
(30.5 cm)
5-1/2" (14 cm)
8"
(20.3 cm)
18" (45.7 cm)
upper cabinet to countertop
gas line opening to be
located in this area
junction box to be
located in this area
12" (30.5 cm) min. clearance from both sides of range to side wall or other combustible material above cooking surface
0" (0 cm) clearance from both sides and back of range to adjacent combustible construction below cooking surface
For minimum clearance to top of range, see NOTE.*
40"
(101.6 cm)
4"
(10.2 cm)
3" (7.6 cm) maximum
gas line height
3-1/2" (8.9 cm)
maximum junction
box height
48" (121.9 cm)
cooktop width
48" (121.9 cm)
width
13-1/2"
(34.3 cm)
36" (91.4 cm) cooktop height with feet loosened 3/4 turns
NOTE: regulator located at center bottom of range.
48" (121.9 cm) range with all sealed burners shown
49-1/2" (125.7 cm)
overall height
1/4" (6.4 mm)
spacer
26-1/2" (67.3 cm)
depth with
control panel