KITCHENAID KDDS 6010 KA Installation Instructions

KDDS 6010
Assembly instructions
5019_106_00864_FLYER_GB 30-05-2007 13:44 Pagina 1
5019_106_00864_FLYER_GB 30-05-2007 13:44 Pagina 2
Before you start 4
Width of the panel 5
Height of the panel 5
Low installations 6
Parts supplied 7
Tools needed 7
Panel preparation instructions 8
Step 1: badge and handle position 8
Step 2: badge cut-out & bracket removal 9
Step 3: fitting the handle and badge 10
Step 4: securing the mounting bracket 11
Step 5: earthing the mounting bracket 12
Step 6: connecting the badge wires 13
Step 7: fitting the panel to the product 14
Customer care 14
5019_106_00864_FLYER_GB 30-05-2007 13:44 Pagina 3
PLEASE NOTE: Your model of may different from the model shown in the diagramas.
Diagrams have been simplified to enable clearer instruction.
FOLLOW THESE INSTRUCTIONS BEFORE REFERRING TO PRODUCT INSTALLATION
INSTRUCTION SHEET P/N 526609.
WARNING
Ensure the product is not plugged in.
The door of the can be made to match your kitchen cabinetry. This diagram, with the
additional of your own measurements will help you calculate the required panel sizes.
CABINETRY ALIGNMENT
The following calculations assume:
The top of the Panel is to be aligned with the top of the adjacent cabinetry.
R
R
Before you start
5mm
MIN.
open
Installer must leave
9mm gap for
correct ventilation.
9mm
AIR
GAP
2,5mm
MINIMUM
CLEARANCE
5mm
MINIMUM
CLEARANCE
Width of the Panel.
9mm
AIR GAP
Height
of
Panel
Panel
2,5mm
MINIMUM
CLEARANCE
Bench Top
Adjacent
Cabinetry
AI
R
FLOW
Adjacent
Cabinetry
Front View of
Top of door must not
overlap cabinetry
Bench Top
5mm
MINIMUM
CLEARANCE
9mm
AIR GAP
Side View of
Cabinetry
4
5019_106_00864_FLYER_GB 30-05-2007 13:44 Pagina 4
Measure A the width between adjacent door/drawer fronts and write it in the first box below, then
complete the equation.
For example:
Width of the panel
2x
600mm
2,5mm
595mm
2 X
door clearance
panel width
(595mm MIN)
door clearance
(2,5mm MIN)
panel width
(595mm MIN)
Measure B door/drawer (or equivalent) and write it in the first box below, then complete the equation.
For example:
Note: When the top of the has to be lower than the adjacent cabinetry, the Panel can be increased
in height.
WARNING
The air vent between the Panel and the adjacent cabinetry must not be covered. An air gap of 9
mm MUST be povided.
R
Height of the panel
9mm
air gap
panel height
(398mm MIN)
407mm
9mm
398mm
air gap
panel height
(398mm MIN)
5
5019_106_00864_FLYER_GB 30-05-2007 13:44 Pagina 5
Loading...
+ 11 hidden pages