Dimensions
shown
with feet extended
1” from bottom of dryer.
back exhaust
al block cover
Explosion Hazard
Keep flammable materials and
vapors, such as gasoline, away from
dryer.
Place dryer at least 18 inches above
the floor for a garage installation.
Failure to do so can result in death,
explosion, or fire.
27” -
bottom exhaust
For proper drying performance:
The location must provide:
)/Level floor: Maximum slope under entire
dryer
)/Protection from weather and water: Do not
should not be more than 1 inch. (If slope is greater
store or use dryer where
it will be exposed to
than 1 inch, install Extended Dryer Feet Kit, Part
water and weather.
No. 279810.) Clothes may not tumble properly and
C/Room temperature above 45°F: If room
automatic sensor cycles may not operate correctly if
dryer
is not level.
temperature is below 45”F, automatic cycles may
not shut off.
dSturdy floor to support dryer weight of
7-l/4”
120 pounds.
( !:
-
It is your responsibility to:
d/Observe all governing codes and ordinances.
d/Comply with the installation specifications and
(/Properly install dryer.
L/Check code requirements:
Some codes limit or
dimensions.
C/Contact a qualified installer to insure that the
do not permit installation of clothes dryers in
L/Consider spacing requirements for companion
electrical installation meets all national and local
garages, closets, mobile homes or sleeping appliances.
codes and ordinances.
quarters. Contact your local building inspector.
)/Make sure you have everything necessary for proper
installation.
Recessed area/closet installation
Installation clearances
Recessed area installation
Closet/confined area installation
Use recommended clearance for easier installation.
The dryer must be exhausted to the outdoors.
WARNING - To reduce the risk of fire, this
appliance MUST BE EXHAUSTED OUTDOORS.
If a closet door is installed: The minimum
unobstructed air openings are required. Louvered
doors with equivalent air openings are acceptable.
9 A clothes dryer produces combustible lint and
should be exhausted outdoors.
l
If codes permit, dryer may be installed in a
recessed area or closet using dimensions shown.
9 Dimensions are in inches and are the minimum
allowable.
. Additional spacing should be considered for ease
of installation and servicing. Companion
appliance spacing should also be considered.
24s
* Wall, door and floor molding may require
additional
spacing.
*** External exhaust elbow requires additional space.
Important: Observe all governing codes and
ordinances.
A four-wire or three-wire, single phase, 120/240volt, 60-Hz, AC-only, electrical supply (or four-wire
or three-wire, 120/208-volt if specified on
model/serial rating plate) is required on a separate
30-ampere circuit, fused on both sides of the line.
A
time-delay fuse or circuit breaker is recommended.
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Recommended ground method
Do not remove ground prong.
It is the personal responsibility and obligation of the
Do not use an adapter.
customer to contact a qualified electrician to assure
Do not use an extension cord.
that the electrical installation is adequate and is in
Failure to follow these instructions can result
conformance with the National Electrical Code,
ANSI/NFPA 70 - latest edition***** and all local
in death, fire, or electrical shock.
codes and ordinances.
If codes permit and a separate ground wire is
Copies of the standards listed above may be obtained
used, it is recommended that a qualified electrician
from:
determine that the ground path is adequate.
*****National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Panel A